Diego Pérez-Estévez

Dr. Diego Pérez-Estévez

Universidade de Vigo
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Diego Pérez-EstévezDiego Pérez-Estévez
Diego Pérez-Estévez
Jesus Doval-GandoyJesus Doval-Gandoy
Jesus Doval-Gandoy
Alejandro G. YepesAlejandro G. Yepes
Alejandro G. Yepes
OSOscar López Sánchez
Oscar López Sánchez
FBFernando Baneira
Fernando Baneira
Conventional resonant controllers (RCs) are commonly used in the current control of grid-tied converters with LCL filter due to their advantages, such as zero steady-state error at both fundamental sequences, easy design process, and straightforward implementation. Nevertheless, these traditional solutions do not permit to place the closed-loop poles of the system in convenient locations when dealing with a fourth-order plant model like the LCL filter plus the computation delay. Therefore, the reference tracking and the disturbance rejection are deficient in terms of transient behavior and depend on the LCL filter. Furthermore, an additional active damping method usually has to be designed in order to ensure stability. This article presents an enhanced current RC with stable and fast response, negligible overshoot, good disturbance rejection, and low controller effort for grid-tied converters with LCL filter. The developed solution uses a direct discrete-time pole-placement strategy from the classical control theory (using transfer functions), involving two extra filters, to enhance the performance of the RC. In this manner, the complexity of state-space methods from modern control theory is avoided. Simulation and experimental results are provided to verify the effectiveness of the proposed control scheme.

23 April 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Diego Pérez-EstévezDiego Pérez-Estévez
Diego Pérez-Estévez
Jesus Doval-GandoyJesus Doval-Gandoy
Jesus Doval-Gandoy
Alejandro G. YepesAlejandro G. Yepes
Alejandro G. Yepes
OSOscar López Sánchez
Oscar López Sánchez
FBFernando Baneira
Fernando Baneira
This article presents a grid-side current controller for grid-tied inverters with LCL filter, including harmonic current elimination. The proposed controller only measures the grid current and voltage and it combines excellent dynamic characteristics with good robustness. Contrarily to previously proposed harmonic-current controllers, the presented solution offers a generalized method that gives a consistent (with minimal variation in the reference-tracking dynamics) and stable performance irrespectively of the number of current harmonics to be canceled and of the resonant frequency of the LCL filter (provided that it is lower than the Nyquist frequency). The response to reference commands is completely damped and fast. The response speed is set in accordance with the low-pass characteristic of the LCL filter so as to limit the control effort. Concerning the disturbance rejection, the controller offers an infinite impedance to any disturbances (such as grid voltage harmonics) at a set of arbitrarily specified frequencies. This allows the designer to eliminate all the undesired current harmonics with a simple design process. In addition, the performance of the presented controller is evaluated in terms of a fundamental tradeoff that exists between robustness to variations in the grid impedance and the number of frequency components rejected. Finally, simulation and experimental results that validate the proposal are presented.

14 August 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
OSOscar López Sánchez
Oscar López Sánchez
JAJacobo Alvarez
Jacobo Alvarez
Alejandro G. YepesAlejandro G. Yepes
Alejandro G. Yepes
FBFernando Baneira
Fernando Baneira
Diego Pérez-EstévezDiego Pérez-Estévez
Diego Pérez-Estévez
Jesus Doval-GandoyJesus Doval-Gandoy
Jesus Doval-Gandoy
The space vector pulse width modulation (PWM) (SVPWM) techniques enhance the performance of multilevel multiphase inverters. With multilevel (three-phase) inverters and with (two-level) multiphase inverters, it is widely accepted that the typical SVPWM strategies have an equivalent carrier-based PWM (CBPWM) counterpart, which produces identical results. However, the conclusions reached in the papers that show these cannot be applied, nor even extended, to SVPWM techniques with more than two levels and three phases. This paper shows that the most widely accepted multilevel multiphase SVPWM techniques have a fully equivalent CBPWM counterpart, which consists of a phase disposition PWM (PDPWM) with an appropriate zero-sequence injection scheme. Closed-form expressions to calculate the zero sequences are provided. The proposed modulation techniques are simulated and then implemented in a field-programmable gate array (FPGA), showing that the equivalent CBPWM techniques produce identical results as the original SVPWM ones, but with a significant reduction of hardware requirements. The proposed methodology can be generalized to other multilevel multiphase SVPWM techniques.

19 January 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Open access
Diego Rios-CastroDiego Rios-Castro
Diego Rios-Castro
Diego Pérez-EstévezDiego Pérez-Estévez
Diego Pérez-Estévez
Jesus Doval-GandoyJesus Doval-Gandoy
Jesus Doval-Gandoy
Grid-connected converters must remain coupled to the grid during a fault. They have to control the reactive currents injected to the grid because of its limited overload capacity. Particularly, grid-forming (GFM) converters ride through the fault either preserving grid-forming operation or switching from grid-forming to grid-following (GFL) mode. In GFM mode the current cannot be controlled therefore mechanisms as virtual impedances become necessary. This article proposes a converter with grid-forming and grid-following capabilities that demonstrates effective voltage tracking in GFM mode and current tracking in GFL mode, good dynamic disturbance rejection response and, wide stability range and robustness in both modes. During a fault, the proposed converter switches from grid-forming to grid-following mode in order to precisely control the injected currents. The current control is able to limit the current at the inception of severe faults. This characteristic is preserved for a wide range of grid impedances, thanks to its good robustness and wide stability margin. As a result, the controller can operate in stand-alone mode, connected to a weak grid, or connected to a stiff grid with a short-circuit ratio up to 50. The fault-ride through capability of the converter is tested under severe symmetrical and asymmetrical faults.

31 March 2016 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Alejandro G. YepesAlejandro G. Yepes
Alejandro G. Yepes
FBFernando Baneira
Fernando Baneira
JMJano Malvar
Jano Malvar
AVAna Vidal
Ana Vidal
Diego Pérez-EstévezDiego Pérez-Estévez
Diego Pérez-Estévez
Jesus Doval-GandoyJesus Doval-Gandoy
Jesus Doval-Gandoy
Multiphase (MP) induction machines (IMs) provide important advantages over three-phase (3P) ones. Sensorless speed estimation makes it possible to obtain high-performance control and monitoring without the inconveniences of speed sensors. In 3P IMs, the speed estimation methods based on rotor slot harmonics (RSHs), normally on the principal RSHs (PSHs), are well established. A difficulty of these techniques, in 3P IMs, is that RSHs are usually extremely small. Additionally, as previously assessed concerning 3P IMs, the number of rotor bars should be carefully selected; otherwise, the PSHs might not even arise in the stator current. However, no publications have addressed the magnitude of PSHs in MP IMs, in comparison to 3P ones, or selection criteria of MP IMs for speed-sensorless drives. In this paper, it is shown that in MP IMs larger (easier to detect) PSHs can be obtained, due to the low impedances in their additional stator planes, by appropriately selecting the number of bars and poles so that the PSHs are mapped into such planes. This finding is supported by newly developed stator equivalent circuits, which include the effects of rotor bars. Accordingly, criteria are presented to select MP IMs for speed-sensorless drives. Experimental and finite-element results confirm the theory.

18 September 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Diego Pérez-EstévezDiego Pérez-Estévez
Diego Pérez-Estévez
Jesus Doval-GandoyJesus Doval-Gandoy
Jesus Doval-Gandoy
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
This article presents an ac voltage controller that can operate under a wide range of loads, thanks to its high robustness to plant-model variations. A robust voltage controller is required in a droop-controlled inverter that operates connected to a grid or in island mode with other generators. In such modes of operation, the voltage source converter can experience large load-impedance variations depending on the number of parallel generators or the grid impedance value. Concerning the controller performance, the transient response is improved by selectively minimizing the output impedance of the system at the frequencies that typically contain the largest components of the output current. Complete harmonic control is achieved due to its zero output impedance at a set of design-selected frequencies. The proposed controller only measures the output voltage, and it contains a single-loop structure that uses all available bandwidth. In addition, a fast converter-current estimator provides protection against faults and inrush output currents. The design process only requires, as input parameters, the LC filter values, the sampling frequency, and a set of harmonics where load-current circulation is expected.