26 January 2010 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Alejandro G. YepesAlejandro G. Yepes
Alejandro G. Yepes
FFFrancisco D. Freijedo
Francisco D. Freijedo
Jesus Doval-GandoyJesus Doval-Gandoy
Jesus Doval-Gandoy
OSOscar López Sánchez
Oscar López Sánchez
JMJano Malvar
Jano Malvar
PFPablo Fernandez-Comesaña
Pablo Fernandez-Comesaña
Resonant controllers have gained significant importance in recent years in multiple applications. Because of their high selectivity, their performance is very dependent on the accuracy of the resonant frequency. An exhaustive study about different discrete-time implementations is contributed in this paper. Some methods, such as the popular ones based on two integrators, cause that the resonant peaks differ from expected. Such inaccuracies result in significant loss of performance, especially for tracking high-frequency signals, since infinite gain at the expected frequency is not achieved, and therefore, zero steady-state error is not assured. Other discretization techniques are demonstrated to be more reliable. The effect on zeros is also analyzed, establishing the influence of each method on the stability. Finally, the study is extended to the discretization of the schemes with delay compensation, which is also proved to be of great importance in relation with their performance. A single-phase active power filter laboratory prototype has been implemented and tested. Experimental results provide a real-time comparison among discretization strategies, which validate the theoretical analysis. The optimum discrete-time implementation alternatives are assessed and summarized.

14 January 2019 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
AMAjay Kumar Morya
Ajay Kumar Morya
MGMatthew C. Gardner
Matthew C. Gardner
BABahareh Anvari
Bahareh Anvari
LLLiming Liu
Liming Liu
Alejandro G. YepesAlejandro G. Yepes
Alejandro G. Yepes
HTHamid A. Toliyat
Hamid A. Toliyat
Wide bandgap (WBG) device-based power electronics converters are more efficient and lightweight than Silicon-based converters. WBG devices are an enabling technology for many motor drive applications and new classes of compact and efficient motors. This paper reviews the potential applications and advances enabled by WBG devices in ac motor drives. Industrial motor drive products using WBG devices are reviewed and the benefits are highlighted. This paper also discusses the technical challenges, converter design considerations and design trade-offs in realizing the full potential of WBG devices in motor drives. There is a trade-off between high switching frequency and other issues such as high dv/dt and electromagnetic interference. The problems of high common mode currents and bearing and insulation damage, which are caused by high dv/dt, and the reliability of WBG devices are discussed.

8 July 2014 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
LHLennart Harnefors
Lennart Harnefors
Alejandro G. YepesAlejandro G. Yepes
Alejandro G. Yepes
AVAna Vidal
Ana Vidal
Jesus Doval-GandoyJesus Doval-Gandoy
Jesus Doval-Gandoy
The time delay in the current control loop of a grid-connected voltage-source converter (VSC) may cause destabilization of electrical resonances in the grid or in the VSC's input filter. Instability is prevented if the input admittance of the VSC can be made passive. This paper presents an analytical controller design method for obtaining passivity. The method is equally applicable to single- and three-phase systems, i.e., in the latter case, for both stationary- and synchronous-frame control. Simulations and experiments verify the theoretical results.

10 March 2011 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Alejandro G. YepesAlejandro G. Yepes
Alejandro G. Yepes
FFFrancisco D. Freijedo
Francisco D. Freijedo
OSOscar López Sánchez
Oscar López Sánchez
Jesus Doval-GandoyJesus Doval-Gandoy
Jesus Doval-Gandoy
The following two types of resonant controllers are mainly employed to obtain high performance in voltage-source converters: 1) proportional + resonant (PR) and 2) vector proportional + integral (VPI). The analysis and design of PR controllers is usually performed by Bode diagrams and phase-margin criterion. However, this approach presents some limitations when resonant frequencies are higher than the crossover frequency defined by the proportional gain. This condition occurs in selective harmonic control and applications with high reference frequency with respect to the switching frequency, e.g., high-power converters with a low switching frequency. In such cases, additional 0-dB crossings (phase margins) appear; therefore, the usual methods for simple systems are no longer valid. In addition, VPI controllers always present multiple 0-dB crossings in their frequency response. In this paper, the proximity to the instability of PR and VPI controllers is evaluated and optimized through Nyquist diagrams. A systematic method is proposed to obtain the highest stability and avoidance of closed-loop anomalous peaks: it is achieved by the minimization of the inverse of the Nyquist trajectory distance to the critical point, i.e., the sensitivity function. Finally, several experimental tests, including an active power filter that operates at a low switching frequency and compensates harmonics up to the Nyquist frequency, validate the theoretical approach.

29 January 2010 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
OSOscar López Sánchez
Oscar López Sánchez
FFFrancisco D. Freijedo
Francisco D. Freijedo
Alejandro G. YepesAlejandro G. Yepes
Alejandro G. Yepes
PFPablo Fernández-Comesaña
Pablo Fernández-Comesaña
JMJano Malvar
Jano Malvar
Jesus Doval-GandoyJesus Doval-Gandoy
Jesus Doval-Gandoy
For low-power grid-connected applications, a single-phase converter can be used. In photovoltaic (PV) applications, it is possible to remove the transformer in the inverter to reduce losses, costs, and size. Galvanic connection of the grid and the dc sources in transformerless systems can introduce additional ground currents due to the ground parasitic capacitance. These currents increase conducted and radiated electromagnetic emissions, harmonics injected in the utility grid, and losses. Amplitude and spectrum of the ground current depend on the converter topology, the switching strategy, and the resonant circuit formed by the ground capacitance, the converter, the ac filter, and the grid. In this paper, the ground current in a 1.5-kW PV installation is measured under different conditions and used to build a simulation model. The installation includes a string of 16 PV panel, a full-bridge inverter, and an LCL filter. This model allows the study of the influence of the harmonics injected by the inverter on the ground current.

12 August 2010 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Alejandro G. YepesAlejandro G. Yepes
Alejandro G. Yepes
FFFrancisco D. Freijedo
Francisco D. Freijedo
OSOscar López Sánchez
Oscar López Sánchez
Jesus Doval-GandoyJesus Doval-Gandoy
Jesus Doval-Gandoy
Resonant controllers are one of the highest performance alternatives for ac current/voltage control. The implementations based on two integrators are widely employed to achieve frequency adaptation without substantial computational burden. However, the discretization of these schemes causes a significant error both in the resonant frequency and in the phase lead provided by the delay compensation. Therefore, perfect tracking is not assured, and stability may be compromised. This paper proposes solutions for both problems without adding a significant resource consumption by correction of the roots placement. A simple expression to calculate the target leading angle, in delay compensation schemes, is also proposed to improve stability margins by means of a better accuracy than previous approaches. Experimental results obtained with a laboratory prototype corroborate the theoretical analysis and the improvement achieved by the proposed discrete-time implementations.