This study evaluated color stability, surface roughness and flexural strength of acrylic resin after immersion in alkaline peroxide and alkaline hypochlorite solutions, simulating a five-year-period of use. Sixty disc-shaped (16x4 mm) and 60 rectangular specimens (65x10x3.3 mm) were prepared from heat-polymerized acrylic resin (Lucitone 550) and assigned to 3 groups (n=20) of immersion (20 min): C1: distilled water; AP: warm water and one alkaline peroxide tablet; SH: 0.5% NaOCl solution. Color data (∆E) were determined by a colorimeter and also quantified according to the National Bureau of Standards units. A rugosimeter was used to measure roughness (μm) and the flexural strength (MPa) was measured using a universal testing machine. Data were evaluated by Kruskal-Wallis followed by Dunn tests (color stability and surface roughness) and by one-way ANOVA and Bonferroni test (flexural strength). For all tests was considered α=0.05. AP {0.79 (0.66;1.42)} caused color alteration significantly higher than C1 {0.45 (0.37;0.57)} and SH {0.34 (0.25;0.42)}. The mean ∆Ε values quantified by NBS were classified as "trace" for C1 (0.43) and SH (0.31) and "slight" for AP (0.96). SH {-0.015 (-0.023;0.003)} caused significantly higher ΔRa than the C1 {0.000 (-0.004;0.010)} and AP {0.000 (-0.009;0.008)} groups. There was no statistically significant difference among the solutions for flexural strength (C1: 84.62±16.00, AP: 85.63±12.99, SH: 84.22±14.72). It was concluded that immersion in alkaline peroxide and NaOCl solutions simulating a five-year of 20 min daily soaking did not cause clinically significant adverse effects on the heat-polymerized acrylic resin.
1 June 2017 in The Journal of Prosthetic Dentistry
The present study aimed to evaluate the retention and stress distribution of conventional (C) RPD and compare to RPD associated to implant for support (IS) and retention (IR). Frameworks were cast from cp Ti (n=18) and Co-Cr alloy (n=18) by plasma and injected by vacuum-pressure. Conventional RPDs were compared to implant associated RPDs using a distal implant to support (IS) or to support and retain (IR) RPD. The specimens were subjected to insertion/removal cycles simulating 5 years of use and the retention force (N) was measured or evaluated. A mixed linear model was used to analyze the data (α=0.05). Photoelastic models were qualitatively examined for stress when an occlusal load of 15 kgf was applied over support teeth and RPD. Retention force of IR RPDs is greater than IS and C RPDs for both cp Ti and Co-Cr alloy specimens. Retention force of cp Ti RPDs increased initially and was maintained throughout 5 years of simulation test while Co-Cr RPDs presented a decrease at the beginning of the test and had their retention force maintained throughout the test. Implant placement at residual alveolar ridge decreased stress around teeth, mainly in the first premolar. Stress concentration in the IS RPD is slightly greater than in the IR RPD. The results suggest that implant placement at the distal extension improves retention and stress distribution of RPDs.