This paper presents a theoretical study on a photonic crystal fiber (PCF) surface plasmon resonance biosensor. The proposed PCF sensor introduces the concept of simultaneous detection with H E11x and H E11x modes, which opens up some possibilities for multianalyte/multichannel sensing. Analysis was performed which considered the operation of the sensor in both amplitude and wavelength interrogation modes. Typical sensor resolutions of 4×10-5 RIU and 8×10-5 RIU with respect to H E11x and H E11y, respectively, are reported for the amplitude interrogation mode, while resoutions of 5 × 10-5 RIU and 6×10-5 RIU are reported for H E11x and H E11y, respectively, for the wavelength interrogation mode.
In this paper, we report a design of high sensitivity Photonic Crystal Fiber (PCF) sensor with high birefringence and low confinement losses for liquid analyte sensing applications. The proposed PCF structures are designed with supplementary elliptical air holes in the core region vertically-shaped V-PCF and horizontally-shaped H-PCF. The full vectorial Finite Element Method (FEM) simulations performed to examine the sensitivity, the confinement losses, the effective refractive index and the modal birefringence features of the proposed elliptical air hole PCF structures. We show that the proposed PCF structures exhibit high relative sensitivity, high birefringence and low confinement losses simultaneously for various analytes.
A numerical analysis of a novel birefringent photonic crystal fiber (PCF) biosensor constructed on the surface plasmon resonance (SPR) model is presented in this paper. This biosensor configuration utilizes circular air holes to introduce birefringence into the structure. This PCF biosensor model shows promise in the area of multiple detection using HE x11 and HE y11 modes to sense more than one analyte. A numerical study of the biosensor is performed in two interrogation modes: amplitude and wavelength. Sensor resolution values with spectral interrogation yielded 5 × 10 -5 RIU (refractive index units) for HE x11 modes and 6 × 10 -5 RIU for HE y11 modes, whereas 3 × 10 -5 RIU for HE x11 modes and 4 × 10 -5 RIU for HE y11 modes are demonstrated for the amplitude interrogation.
In this paper, we report a unique multi-channel Photonic Crystal Fiber (PCF) sensor based on Surface Plasmon Resonance (SPR) structure comprising of silver and gold doped plasmonic layers for multi-analyte sensing applications. We deployed a Full Vectorial Finite Element Method (FVFEM) to investigate the sensitivity performance of the proposed PCF sensor. The SPR sensor is fully optimised to ensure propagation features, such as confinement loss, resonance condition, resolution and sensitivity are investigated within various optimised design parameters. According to spectral sensitivity analyses, 2500 nm/RIU and 3083 nm/RIU with $4 \times 10^{-5}$ RIU and $3.2 \times 10^{-5}$ RIU resolutions are obtained for Channel 1 (Ch1) (x-polarized) and Channel 2 (Ch2) (y-polarized), respectively.