Shyqyri Haxha

Dr. Shyqyri Haxha

Royal Holloway University of London
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2016 in IEEE Photonics Journal
Verified
Journal Article
Open access
Shyqyri HaxhaShyqyri Haxha
Shyqyri Haxha
JJJaspreet Jhoja
Jaspreet Jhoja
Diabetes mellitus claims millions of lives every year. It affects the body in various ways by leading to many serious illnesses and premature mortality. Heart and kidney diseases, which are caused by diabetes, are increasing at an alarming rate. In this paper, we report a study of a noninvasive measurement technique to determine the glucose levels in the human body. Current existing methods to quantify the glucose level in the blood are predominantly invasive that involve taking the blood samples using finger pricking. In this paper, we report a spectroscopy-based noninvasive glucose monitoring system to measure glucose concentration. Near-infrared transmission spectroscopy is used and in vitro experiments are conducted, as well as in vivo. Our experimental study confirms a correlation between the sensor output voltage and glucose concentration levels. We report a low-cost prototype of spectroscopy-based noninvasive glucose monitoring system that demonstrates promising results in vitro and establishes a relationship between the optical signals and the changing levels of blood–glucose concentration.

20 December 2019 in IEEE Photonics Journal
Verified
Journal Article
Open access
AYAhmet Yasli
Ahmet Yasli
HAHuseyin Ademgil
Huseyin Ademgil
Shyqyri HaxhaShyqyri Haxha
Shyqyri Haxha
AAAmar Aggoun
Amar Aggoun
In this paper, we report a unique multi-channel Photonic Crystal Fiber (PCF) sensor based on Surface Plasmon Resonance (SPR) structure comprising of silver and gold doped plasmonic layers for multi-analyte sensing applications. We deployed a Full Vectorial Finite Element Method (FVFEM) to investigate the sensitivity performance of the proposed PCF sensor. The SPR sensor is fully optimised to ensure propagation features, such as confinement loss, resonance condition, resolution and sensitivity are investigated within various optimised design parameters. According to spectral sensitivity analyses, 2500 nm/RIU and 3083 nm/RIU with $4 \times 10^{-5}$ RIU and $3.2 \times 10^{-5}$ RIU resolutions are obtained for Channel 1 (Ch1) (x-polarized) and Channel 2 (Ch2) (y-polarized), respectively.

31 October 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Shyqyri HaxhaShyqyri Haxha
Shyqyri Haxha
FAF. AbdelMalek
F. AbdelMalek
FOF. Ouerghi
F. Ouerghi
MCM. D. B. Charlton
M. D. B. Charlton
AAA. Aggoun
A. Aggoun
XFXu Fang
Xu Fang
In this paper, a novel design for a metamaterial lens (superlens) based on a Photonic Crystal (PC) operating at visible wavelengths is reported. The proposed superlens consist of a gallium phosphide (GaP) dielectric slab waveguide with a hexagonal array of silver rods embedded within the GaP dielectric. In-house 2DFDTD numerical method is used to design and optimize the proposed superlens. Several superlenses are designed and integrated within a same dielectric platform, promoting the proof-of-concept (POC) of possible construction of an array of superlenses (or sub-lenses to create an M-Lens) for light field imaging applications. It is shown that the concavity of the superlens and positioning of each sub-lens within the array strongly affects the performances of the image in terms of resolution. Defects and various geometrical shapes are introduced to construct and optimize the proposed superlenses and increase the quality of the image resolution. It is shown that the orientation of the active region (ellipse) along x and y axis has tremendous influence on the quality of image resolution. In order to investigate the performance characteristics of the superlenses, transmitted power is calculated using 2D FDTD for image projections at various distances (in x and y plane). It is also shown, how the proposed superlens structures could be fabricated using standard micro fabrication techniques such as electron beam lithography, inductively coupled Reactive ion etching, and glancing angle evaporation methods. To the best of our knowledge, these are the first reported POC of superlenses, integrated in a monolithic platform suitable for high imaging resolution that can be used for light field imaging applications at visible wavelength. The proposed superlenses (integrated in a single platform M-Lens) will have tremendous impact on imaging applications.

13 January 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CNChike Nwibor
Chike Nwibor
Shyqyri HaxhaShyqyri Haxha
Shyqyri Haxha
AMAli Mian
Ali Mian
MSMohamed Sakel
Mohamed Sakel
AHAnda Rexha Haxha
Anda Rexha Haxha
SNShakira Nabakooza
Shakira Nabakooza
This paper presents the design and implementation of an Internet of Things-based remote health monitoring system for the estimation of Blood Pressure (BP), Heart Rate (HR) and blood oxygen saturation levels (SpO2). Our designed sensor can remotely monitor BP, HR and SpO2. Our device collects, evaluates, predicts and reads health data and then stores it on a remote platform named ‘ThinkSpeak’, which forms an Internet of Things (IoT) platform, with a 0.91 Organic Light-Emitting Diodes (OLED) screen display for viewing numerical health readings locally. We used a biomedical sensor device with an embedded signal condition unit, a single Photoplethysmography (PPG) signal was employed to derive and measure the PPG signal. A computer-based algorithm was generated which factored in selected beneficial parameters measured from a single bio-inspired PPG signal. The measured PPG signal was used to estimate the individual user’s BP (both systolic and diastolic values), HR and SpO2 respectively. An Automatic Multiscale-Based Peak (AMBP) detection algorithm was developed to obtain the maximum peak of the PPG signal. Furthermore, the developed sensor was benchmarked against two standard commercially available measurement devices: a contec ambulatory BP sensor and a Braun pulse oximeter monitor. Our developed sensor is worn as a ring sensor and is interfaced with an Arduino 1010 WIFI MKR for remote health monitoring. Our estimated BP, HR and SpO2 values were remotely monitored and a graphical representation was constructed.

7 December 2019 in Wireless Personal Communications
Verified
Journal Article
Closed access
PDF file
MAMian Mujtaba Ali
Mian Mujtaba Ali
Shyqyri HaxhaShyqyri Haxha
Shyqyri Haxha
MAMunna M. Alam
Munna M. Alam
CNChike Nwibor
Chike Nwibor
MSMohamed Sakel
Mohamed Sakel

20 May 2020 in IEEE Systems Journal
Verified
Journal Article
Closed access
Hichem MrabetHichem Mrabet
Hichem Mrabet
ACAbdelhamid Cherifi
Abdelhamid Cherifi
TRThiago Raddo
Thiago Raddo
IDIyad Dayoub
Iyad Dayoub
Shyqyri HaxhaShyqyri Haxha
Shyqyri Haxha
This article presents a detailed survey on both asynchronous and synchronous Optical Code-Division Multiple-Access (OCDMA) systems based on 1-D, 2-D, and 3-D codes, distinctively. Accordingly, different coding schemes along with their multiplexing capacity, correlation features, advantages and drawbacks are addressed and benchmarked. Additionally, different detection techniques such as direct and coherent detection and their capability to handle Multiple Access-Interference are also discussed. Furthermore, the main OCDMA systems from the last two decades are summarized considering their coding schemes, performance, device components, and applications. Therefore, a new comparative study in terms of spectral efficiency and bit error rate for 1-D, 2-D, and 3-D asynchronous and synchronous OCDMA systems is carried out. Numerical results shown that the 3-D MD code stands out among the codes with superior performance as well as support to higher data rates and number of users.