Bernhard Dorweiler

Dr. Bernhard Dorweiler

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2021 in Materials
Verified
Journal Article
Open access
PDF file
BDBernhard Dorweiler
Bernhard Dorweiler
PBPia-Elisabeth Baqué
Pia-Elisabeth Baqué
RCRayan Chaban
Rayan Chaban
AGAhmed Ghazy
Ahmed Ghazy
OSOroa Salem
Oroa Salem
As comparative data on the precision of 3D-printed anatomical models are sparse, the aim of this study was to evaluate the accuracy of 3D-printed models of vascular anatomy generated by two commonly used printing technologies. Thirty-five 3D models of large (aortic, wall thickness of 2 mm, n = 30) and small (coronary, wall thickness of 1.25 mm, n = 5) vessels printed with fused deposition modeling (FDM) (rigid, n = 20) and PolyJet (flexible, n = 15) technology were subjected to high-resolution CT scans. From the resulting DICOM (Digital Imaging and Communications in Medicine) dataset, an STL file was generated and wall thickness as well as surface congruency were compared with the original STL file using dedicated 3D engineering software. The mean wall thickness for the large-scale aortic models was 2.11 µm (+5%), and 1.26 µm (+0.8%) for the coronary models, resulting in an overall mean wall thickness of +5% for all 35 3D models when compared to the original STL file. The mean surface deviation was found to be +120 µm for all models, with +100 µm for the aortic and +180 µm for the coronary 3D models, respectively. Both printing technologies were found to conform with the currently set standards of accuracy (<1 mm), demonstrating that accurate 3D models of large and small vessel anatomy can be generated by both FDM and PolyJet printing technology using rigid and flexible polymers.

23 January 2016 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
MYMarwan Youssef
Marwan Youssef
ZNZmarai Nurzai
Zmarai Nurzai
SZSebastian Zerwes
Sebastian Zerwes
RJRudolf Jakob
Rudolf Jakob
FDFritz Dünschede
Fritz Dünschede
CVChristian F. Vahl
Christian F. Vahl
Purpose: To assess the feasibility and effectiveness of the Nellix prosthesis in the treatment of common iliac artery aneurysms. Methods: Between May 2013 and June 2015, 230 patients underwent implantation of the Nellix device at 2 institutions. Fifty of these patients (mean age 76 years; 35 men) were identified as having 60 common iliac artery aneurysms (CIAAs) with a median diameter of 4 cm (range 3.5–7). The majority of patients had aortoiliac aneurysms (5, 70%), 10 (20%) had isolated CIAAs, and 5 (10%) had iliac anastomotic aneurysms after aortoiliac bypass. In 20 patients, the iliac aneurysm was the indication for the intervention; in the other 30 patients, the endovascular iliac repair was an adjunct procedure to endovascular aneurysm sealing (EVAS). An iliac branch device (IBD) was used when feasible to preserve flow to the internal iliac artery. Results: Seventeen (34%) patients underwent elective implantation of the Nellix graft in combination with an IBD, 33 (66%) patients underwent Nellix sealing of the CIAA using 1 (n=5), 2 (n=22), or 3 Nellix grafts (2 bilateral grafts and 1 graft as an extension to the external iliac artery in 6 patients). The technical success rate was 100%, and no graft-related complications were reported postoperatively. No buttock claudication, reinterventions, graft thrombosis, or endoleaks were observed during a mean follow-up of 12 months. Conclusion: Our initial experience demonstrates that Nellix grafts are feasible and safe for the treatment of extensive iliac artery aneurysms. The long-term durability of these grafts should be validated in larger patient cohorts before this promising alternative endovascular technique can gain widespread acceptance.

11 January 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SMSpyridon Mylonas
Spyridon Mylonas
TATuna Aras
Tuna Aras
BDBernhard Dorweiler
Bernhard Dorweiler
The objective of this study is to present the current outcomes of fenestrated/branched endovascular repair (F/BEVAR) for post-dissection thoracoabdominal aortic aneurysms (PDTAAAs). A systematic review of the literature according to PRISMA guidelines up to October 2023 was conducted (protocol CRD42023473403). Studies were included if ≥10 patients were reported and at least one of the major outcomes was stated. A total of 10 studies with 585 patients overall were included. The pooled estimate for technical success was 94.3% (95% CI 91.4% to 96.2%). Permanent paraplegia developed with a pooled rate of 2.5% (95% CI 1.5% to 4.3%), whereas a cerebrovascular event developed with a pooled rate of 1.6% (95% CI 0.8% to 3.0%). An acute renal function impairment requiring new-onset dialysis occurred with a pooled rate of 2.0% (95% CI 1.0% to 3.8%). Postoperative respiratory failure was observed with a pooled estimate of 5.5% (95% CI 3.8% to 8.1%). The pooled estimate for 12-month overall survival was 90% (95% CI 85% to 93.5%), and the pooled estimates for 24-month and 36-month survival were 87.8% (95% CI 80.9% to 92.5%) and 85.5% (95% CI 76.5% to 91.5%), respectively. Freedom from reintervention was estimated at 83.9% (95% CI 75.9% to 89.6%) for 12 months, 82.8% (95% CI 68.7% to 91.4%) for 24 months and 76.1% (95% CI 60.6% to 86.8%) for 36 months. According to the present findings, F/BEVAR can be performed in PD-TAAAs with high rates of technical success and good mid-term results.

26 July 2024 in Journal of Vascular Surgery
Verified
Journal Article
Open access
OSOroa Salem
Oroa Salem
HBHazem El Beyrouti
Hazem El Beyrouti
JMJoscha Mulorz
Joscha Mulorz
HSHubert Schelzig
Hubert Schelzig
AIAbdelhakim Ibrahim
Abdelhakim Ibrahim
BDBernhard Dorweiler
Bernhard Dorweiler
Several studies have reported short- and intermediate-term outcomes after TEVAR for descending thoracic aortic aneurysm (DTAA), however, reports on long-term (10 years) outcomes are sparse. Therefore, the aim of this study was to analyze predictors impacting long-term outcome following thoracic endovascular aortic repair (TEVAR) for DTAA. Databases from four academic institutions were reviewed and consecutive cases of TEVAR for DTAA between 1999 and 2021 were included in this retrospective multicenter study (Case series). Ethical approval from Institutional review board was obtained and patient demographics, treatment data as well as follow-up information were retrieved and analyzed. 305 patients (mean age 72±10 years) treated with TEVAR for degenerative DTAA with mean aortic diameter of 64mm were identified. Altogether 445 endografts were implanted via femoral access (93%) with a technical success of 94%. Operative mortality, stroke rate and rate of spinal cord ischemia were 6% (5% for intact, 12% for ruptured DTAA), 4% and 3%, respectively. Kaplan-Meier estimates for overall survival rates were 76%, 59% and 34% at 1, 5 and 10 years and freedom from reintervention rates were 84%, 73% and 58% at 1, 5 and 10 years, respectively. In multivariate analysis, ASA grade 3-5 and non-elective case were identified as predictors for death, wheres as fusiform DTAA, proximal landing zone 2 and hypertension but not device generation were predictive for reintervention. This is to date the largest study reporting long-term (10 years) outcome on TEVAR for DTAA. We found acceptable rates for long-term survival and freedom-from reintervention that were independent of endovascular device generation.

28 August 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
WAWael Ahmad
Wael Ahmad
MLMark Liebezeit-Sievert
Mark Liebezeit-Sievert
MWMoritz Wegner
Moritz Wegner
AAAnastasiia Alokhina
Anastasiia Alokhina
TWThorsten Wahlers
Thorsten Wahlers
and Maximilian Luehrand Maximilian Luehr
and Maximilian Luehr
(1) Background: This study aimed to morphologically analyze acute type A aortic dissection (aTAAD) patients for potential endovascular treatment candidates. The objective was to specify requirements for aTAAD endovascular devices. (2) Methods: A single-center retrospective analysis included aTAAD patients who underwent open surgical repair between November 2005 and December 2020. Preoperative CTA scans were used for morphological analysis, assessing endovascular repair eligibility. Statistical tests were performed. (3) Results: A total of 129 patients with aTAAD were studied, with 119 included. Entry tear (ET) locations were identified, mainly in the aortic root, 20 mm above the sinotubular junction (STJ) and within the ascending aorta (20 mm above STJ to −20 mm before the brachiocephalic trunk). Endovascular treatment was deemed feasible for 36 patients, with suggested solutions for the aortic arch and descending aorta. Significant differences were observed between eligible and noneligible groups for aortic diameter, false lumen diameter, distance between STJ and entry tear, and more. Dissection extension showed no significant difference. (4) Conclusions: Morphological analysis identified potential aTAAD candidates for endovascular treatment, highlighting differences between eligible and noneligible morphologies. This study offers insights for implementing endovascular approaches in aTAAD treatment and emphasizes the need for research and standardized protocols.

24 January 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
NHNancy Halloum
Nancy Halloum
AMAnna-Sophie Meyer
Anna-Sophie Meyer
MWMartin Wenkel
Martin Wenkel
DDDaniel-Sebastian Dohle
Daniel-Sebastian Dohle
MYMarwan Youssef
Marwan Youssef
HBHazem El Beyrouti
Hazem El Beyrouti
Background/Objectives: Retrograde false lumen perfusion after thoracic endovascular aortic repair (TEVAR) can compromise positive remodeling and clinical outcomes. The aim of this study is to describe the feasibility and outcomes of a false lumen thrombosis technique. Methods: A single-center, retrospective analysis of patients between January 2017 and January 2022 who underwent TEVAR in conjunction with false lumen embolization. Results: Twelve patients (83% type A, 17% type B; 33% with frank rupture; mean age 65 years; eleven men) underwent 13 false lumen embolization procedures with a 92% technical success rate and a 100% clinical success rate. Positive aortic remodeling was observed in all the patients. The maximum thoracic aortic diameter remained stable (p = 0.526) but the true lumen increased from 22 to 33 mm (p = 0.009) and the false lumen decreased from 41 to 20 mm (p = 0.076) after a median follow-up of 31 months. Conclusions: False lumen embolization using the candy-plug is safe and promotes positive aortic remodeling.