Purpose: Artificial intelligence (AI) using an automated, deep learning–based method, Augmented Radiology for Vascular Aneurysm (ARVA), has been verified as a viable aide in aneurysm morphology assessment. The aim of this study was to evaluate the accuracy of ARVA when analyzing preoperative and postoperative computed tomography angiography (CTA) in patients managed with fenestrated endovascular repair (FEVAR) for complex aortic aneurysms (cAAs). Materials and Methods: Preoperative and postoperative CTAs from 50 patients (n=100 CTAs) who underwent FEVAR for cAAs were extracted from the picture archiving and communication system (PACS) of a single aortic center equipped with ARVA. All studies underwent automated AI aneurysm morphology assessment by ARVA. Appropriate identification of the outer wall of the aorta was verified by manual review of the AI-generated overlays for each patient. Maximum outer-wall aortic diameters were measured by 2 clinicians using multiplanar reconstruction (MPR) and curved planar reformatting (CPR), and among studies where the aortic wall was appropriately identified by ARVA, they were compared with ARVA automated measurements. Results: Identification of the outer wall of the aorta was accurate in 89% of CTA studies. Among these, diameter measurements by ARVA were comparable to clinician measurements by MPR or CPR, with a median absolute difference of 2.4 mm on the preoperative CTAs and 1.6 mm on the postoperative CTAs. Of note, no significant difference was detected between clinician measurements using MPR or CPR on preoperative and postoperative scans (range 0.5–0.9 mm). Conclusion: For patients with cAAs managed with FEVAR, ARVA provides accurate preoperative and postoperative assessment of aortic diameter in 89% of studies. This technology may provide an opportunity to automate cAA morphology assessment in most cases where time-intensive, manual clinician measurements are currently required. Clinical Impact: In this retrospective analysis of preoperative and postoperative imaging from 50 patients managed with FEVAR, AI provided accurate aortic diameter measurements in 89% of the CTAs reviewed, despite the complexity of the aortic anatomies, and in post-operative CTAs despite metal artifact from stent grafts, markers and embolization materials. Outliers with imprecise automated aortic overlays were easily identified by scrolling through the axial AI-generated segmentation MPR cuts of the entire aorta.This study supports the notion that such emerging AI technologies can improve efficiency of routine clinician workflows while maintaining excellent measurement accuracy when analyzing complex aortic anatomies by CTA.
18 October 2023 in Journal of Endovascular Therapy
Purpose: Access-related vascular complications in transfemoral transcatheter aortic valve implantation (TAVI) can be treated endovascularly or surgically. The aim of this study was to evaluate the short- and long-term outcomes of endovascular treatment compared with surgical repair for access-related vascular complications. Methods: This retrospective study was performed from January 1, 2018, to December 31, 2020. All transfemorally treated TAVI patients in whom a surgical or endovascular treatment for an access site complication was needed were included. The primary outcome was the need for any related vascular re-operation. Results: In total, 1219 transfemoral TAVI procedures were conducted during the study period. 19 patients suffered an access complication requiring endovascular treatment, while 54 patients required surgical repair. No differences were seen with regard to re-operations (endovascular 15.8% vs surgical 14.8%; p=0.919), wound infections (endovascular 0% vs surgical. 11.1%; p=0.129), and wound healing disorders (endovascular 15.8% vs surgical 29.6%; p=0.237). Patients undergoing endovascular treatment were discharged earlier (endovascular 11.2 vs surgical 14.9 days; p=0.028). After surgical repair, patients received significantly more blood transfusions than endovascularly treated patients (endovascular 1.00 vs surgical 3.1 red blood cell concentrate bags; p<0.001). No differences were found regarding the new onset of walking pain, rest pain, and ischemic ulcers during follow-up. Conclusion: In this retrospective cohort, endovascular treatment of access-related vascular complications of transfemoral TAVI procedures was safe and feasible. During the hospital stay, endovascularly treated patients received fewer blood transfusions and were discharged faster than surgically treated patients. No differences regarding clinical outcomes and re-intervention rates were seen during the follow-up. Clinical Impact: Given the in this retrospective study demonstrated safety and feasibility of endovascular treatment for major access-related vascular complications, along with the in-hospital benefits and absence of follow-up disadvantages compared to surgical treatment, endovascular treatment should be considered in cases of major access-related vascular complications in transfemoral TAVI patients.
(1) Background: This study aimed to morphologically analyze acute type A aortic dissection (aTAAD) patients for potential endovascular treatment candidates. The objective was to specify requirements for aTAAD endovascular devices. (2) Methods: A single-center retrospective analysis included aTAAD patients who underwent open surgical repair between November 2005 and December 2020. Preoperative CTA scans were used for morphological analysis, assessing endovascular repair eligibility. Statistical tests were performed. (3) Results: A total of 129 patients with aTAAD were studied, with 119 included. Entry tear (ET) locations were identified, mainly in the aortic root, 20 mm above the sinotubular junction (STJ) and within the ascending aorta (20 mm above STJ to −20 mm before the brachiocephalic trunk). Endovascular treatment was deemed feasible for 36 patients, with suggested solutions for the aortic arch and descending aorta. Significant differences were observed between eligible and noneligible groups for aortic diameter, false lumen diameter, distance between STJ and entry tear, and more. Dissection extension showed no significant difference. (4) Conclusions: Morphological analysis identified potential aTAAD candidates for endovascular treatment, highlighting differences between eligible and noneligible morphologies. This study offers insights for implementing endovascular approaches in aTAAD treatment and emphasizes the need for research and standardized protocols.
11 March 2025 in British Journal of Clinical Pharmacology
(1) While three-dimensional (3D) printing technology is increasingly being used for the fabrication of high-fidelity, patient-specific aortic models, data on the mechanical properties of polymers are sparse. Therefore, the aim of this study was to identify suitable polymers for this purpose. (2) Methods: Eight flexible polymers, with Shore A hardnesses (ShA) of 27–85, were tested to determine their suitability for PolyJet printing technology. They were tested against porcine aortic and bovine pericardial tissue for suture retention strength, uniaxial stress testing according to ISO 37, and burst pressure in a standardized test setting. (3) Results: The polymers with a ShA of 30–50 showed statistically non-inferior suture retention strength, tensile strength, and burst pressure resistance when compared to pericardial and aortic tissue, respectively. (4) Conclusions: This was the first report to analyze the mechanical properties of eight different flexible PolyJet polymers. We found that the polymers with a Shore A hardness of 30–50 most closely mimicked the mechanical properties of aortic tissue. Therefore, they can be recommended for the additive manufacturing (3D printing) of aortic phantoms for simulation and training purposes.
25 February 2024 in Journal of Intensive Care Medicine
Background: Individual implementation rate of bronchoscopy-guided percutaneous dilatational tracheostomy (PDT) varies among intensivists. Simulation training (ST) can increase the safety of medical procedures by reducing stress levels of the performing team. The aim of this study was to evaluate the benefit of ST in PDT regarding procedural time, quality of performance, and percepted feelings of safety of the proceduralist and to compare conventional simulators (CSIM) with simulators generated from 3D printers (3DSIM). Methods: We conducted a prospective, single-center, randomized, blinded cross-over study comparing the benefit of CSIM versus 3DSIM for ST of PDT. Participants underwent a standardized theoretical training and were randomized to ST with CSIM (group A) or 3DSIM (group B). After ST, participants’ performance was assessed by two blinded examiners on a porcine trachea regarding time required for successful completion of PDT and correct performance (assessed by a performance score). Percepted feelings of safety were assessed before and after ST. This was followed by a second training and second assessment of the same aspects with crossed groups. Results: 44 participants were included: 24 initially trained with CSIM (group A) and 20 with 3DSIM (group B). Correctness of the PDT performance increased significantly in group B (p < .01) and not significantly in group A (p = .14). Mean procedural time required for performing a PDT after their second ST compared to the first assessment (p < .01) was lower with no difference between group A and group B and irrespective of the participants’ previous experience regarding PDT, age, and sex. Moreover, percepted feelings of safety increased after the first ST in both groups (p < .001). Conclusions: ST can improve procedural skills, procedural time, and percepted feelings of safety of the proceduralist in simulated PDT.