Inka Mueller

Prof. Inka Mueller

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
KTKilian Tschoeke
Kilian Tschoeke
IMInka Mueller
Inka Mueller
Vittorio MemmoloVittorio Memmolo
Vittorio Memmolo
MMMaria Moix-Bonet
Maria Moix-Bonet
Jochen MollJochen Moll
Jochen Moll
LSLars Schubert
Lars Schubert
In many industrial sectors, structural health monitoring (SHM) is considered as an addition to nondestructive testing (NDT) that can reduce maintenance effort during the lifetime of a technical facility, structural component, or vehicle. A large number of SHM methods are based on ultrasonic waves, whose properties change depending on structural health. However, the wide application of SHM systems is limited due to the lack of suitable methods to assess their reliability. The evaluation of the system performance usually refers to the determination of the probability of detection (POD) of a test procedure. Up until now, only a few limited methods exist to evaluate the POD of SHM systems, which prevents them from being standardized and widely accepted in the industry. The biggest hurdle concerning the POD calculation is the large number of samples needed. A POD analysis requires data from numerous identical structures with integrated SHM systems. Each structure is then damaged at different locations and with various degrees of severity. All of these are connected to high costs. Therefore, one possible way to tackle this problem is to perform computer-aided investigations. In this work, the POD assessment procedure established in NDT according to the Berens model is adapted to guided wave-based SHM systems. The approach implemented here is based on solely computer-aided investigations. After efficient modeling of wave propagation phenomena across an automotive component made of a carbon-fiber-reinforced composite, the POD curves are extracted. Finally, the novel concept of a POD map is introduced to look into the effect of damage position on system reliability.

16 January 2017 in Materials
Verified
Journal Article
Open access
PDF file
IMInka Mueller
Inka Mueller
CFClaus-Peter Fritzen
Claus-Peter Fritzen
The use of piezoelectric wafer active sensors (PWAS) for structural health monitoring (SHM) purposes is state of the art for acousto-ultrasonic-based methods. For system reliability, detailed information about the PWAS itself is necessary. This paper gives an overview on frequent PWAS faults and presents the effects of these faults on the wave propagation, used for active acousto-ultrasonics-based SHM. The analysis of the wave field is based on velocity measurements using a laser Doppler vibrometer (LDV). New and established methods of PWAS inspection are explained in detail, listing advantages and disadvantages. The electro-mechanical impedance spectrum as basis for these methods is discussed for different sensor faults. This way this contribution focuses on a detailed analysis of PWAS and the need of their inspection for an increased reliability of SHM systems.

4 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
IMInka Mueller
Inka Mueller
Vittorio MemmoloVittorio Memmolo
Vittorio Memmolo
KTKilian Tschoeke
Kilian Tschoeke
MMMaria Moix-Bonet
Maria Moix-Bonet
KMKathrin Möllenhoff
Kathrin Möllenhoff
Jochen MollJochen Moll
Jochen Moll
To assess the ability of structural health monitoring (SHM) systems, a variety of prerequisites and contributing factors have to be taken into account. Within this publication, this variety is analyzed for actively introduced guided wave-based SHM systems. For these systems, it is not possible to analyze their performance without taking into account their structure and their applied system parameters. Therefore, interdependencies of performance assessment are displayed in an SHM pyramid based on the structure and its monitoring requirements. Factors influencing the quality, capability and reliability of the monitoring system are given and put into relation with state-of-the-art performance analysis in a non-destructive evaluation. While some aspects are similar and can be treated in similar ways, others, such as location, environmental condition and structural dependency, demand novel solutions. Using an open-access data set from the Open Guided Waves platform, a detailed method description and analysis of path-based performance assessment is presented.The adopted approach clearly begs the question about the decision framework, as the threshold affects the reliability of the system. In addition, the findings show the effect of the propagation path according to the damage position. Indeed, the distance of damage directly affects the system performance. Otherwise, the propagation direction does not alter the potentiality of the detection approach despite the anisotropy of composites. Nonetheless, the finite waveguide makes it necessary to look at the whole paths, as singular phenomena associated with the reflections may appear. Numerical investigation helps to clarify the centrality of wave mechanics and the necessity to take sensor position into account as an influencing factor. Starting from the findings achieved, all the issues are discussed, and potential future steps are outlined.

28 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Mikhail V GolubMikhail V Golub
Mikhail V Golub
ASAlisa N. Shpak
Alisa N. Shpak
IMInka Mueller
Inka Mueller
SFSergey Fomenko
Sergey Fomenko
CFClaus-Peter Fritzen
Claus-Peter Fritzen
Since stringers are often applied in engineering constructions to improve thin-walled structures’ strength, methods for damage detection at the joints between the stringer and the thin-walled structure are necessary. A 2D mathematical model was employed to simulate Lamb wave excitation and sensing via rectangular piezoelectric-wafer active transducers mounted on the surface of an elastic plate with rectangular surface-bonded obstacles (stiffeners) with interface defects. The results of a 2D simulation using the finite element method and the semi-analytical hybrid approach were validated experimentally using laser Doppler vibrometry for fully bonded and semi-debonded rectangular obstacles. A numerical analysis of fundamental Lamb wave scattering via rectangular stiffeners in different bonding states is presented. Two kinds of interfacial defects between the stiffener and the plate are considered: the partial degradation of the adhesive at the interface and an open crack. Damage indices calculated using the data obtained from a sensor are analyzed numerically. The choice of an input impulse function applied at the piezoelectric actuator is discussed from the perspective of the development of guided-wave-based structural health monitoring techniques for damage detection.

2 December 2021 in Applied Mechanics
Verified
Journal Article
Open access
PDF file
ABAhmed Bayoumi Mahmoud Bayoumi
Ahmed Bayoumi Mahmoud Bayoumi
TMTobias Minten
Tobias Minten
IMInka Mueller
Inka Mueller
The capabilities of detection and localization of damage in a structure, using a guided wave-based structural health monitoring (GWSHM) system, depend on the damage location and the chosen sensor array setup. This paper presents a novel approach to assess the reliability of an SHM system enabling to quantify localization accuracy. A two-step technique is developed to combine multiple paths to generate one probability of detection (POD) curve that provides information regarding the detection capability of an SHM system at a defined damage position. Moreover, a new method is presented to analyze localization accuracy. Established probability-based diagnostic imaging using a signal correlation algorithm is used to determine the damage location. The resultant output of the localization accuracy analysis is the smallest damage size at which a defined accuracy level can be reached at a determined location. The proposed methods for determination of detection probability and localization accuracy are applied to a plate-like CFRP structure with an omega stringer with artificial damage of different sizes at different locations. The results show that the location of the damage influences the sensitivity of detection and localization accuracy for the used detection and localization methods. Localization accuracy is enhanced as it becomes closer to the array’s center, but its detection sensitivity deteriorates.

16 March 2020 in Smart Materials and Structures
Verified
Journal Article
Open access
PDF file
ASAlisa N Shpak
Alisa N Shpak
IMInka Mueller
Inka Mueller
Mikhail V GolubMikhail V Golub
Mikhail V Golub
CFClaus-Peter Fritzen
Claus-Peter Fritzen
The paper proposes a new hybrid approach technique to simulate acousto-ultrasonic wave excitation and propagation due to operation of the partially debonded piezoelectric transducer attached to a plate-like structure. The semi-analytical boundary integral equation method is applied to calculate guided waves propagation in the unbounded structures and to separate different guided waves in the piezo-induced wave-fields. The obtained model is verified experimentally using the scanning laser Doppler vibrometry. Eigenfrequencies are calculated and analysed for various sizes of the transducer and for different bonding conditions between the transducer and the waveguide. The impact of the transducer’s height, size and debonding area on symmetric and antisymmetric Lamb waves excitation is analysed. The paper demonstrates that one-sided debonding of the transducer exerts intense influence on the distribution of the wave energy among the excited Lamb wave modes, while center debonding has a sizable impact only at relatively high frequencies.