Active Vibration Control (AVC) based on the principle of destructive interference is an effective approach for suppressing low-frequency vibration in modern structures. This review paper presents a systematic review of adaptive filtering algorithms, especially Least Mean Squares (LMS), Filtered-x LMS (FxLMS), and Variable Step-size FxLMS (VSS-FxLMS) algorithms, used in piezoelectric smart structures. These algorithms play a crucial role in enhancing the performance and efficiency of AVC systems, allowing for better control and adaptation to varying vibration conditions. As the application of piezoelectric actuators and sensors for vibration suppression has expanded, adaptive algorithms have become essential for improving the convergence rate, stability, and precision of control. In particular, advancements in algorithmic design have focused on improving robustness under varying operating conditions and increasing the accuracy of suppression. The review highlights major algorithm developments, mathematical formulations, and performance comparisons, along with applications to piezoelectric beams, blades, and plates. While the VSS-FxLMS algorithm demonstrates improved robustness, comprehensive comparative studies across different applications remain limited. A numerical simulation is also presented to evaluate the convergence and vibration suppression performance. This work provides insights into current challenges, recent advances, and promising directions for future AVC system design. Specifically, it identifies the need for more research on real-time system integration, multimodal vibration reduction, and the scalability of adaptive algorithms for intricate, large-scale systems. The findings suggest that hybrid algorithms that incorporate the best features of each of the aforementioned approaches could greatly enhance future AVC systems.
12 January 2022 in Transactions of the Institute of Measurement and Control
A discrete-time-modified Bouc–Wen model is proposed to describe the non-symmetrical and rate-dependent hysteresis of piezoelectric actuators for micro-vibration control applications. The modified model combines a non-symmetrical Bouc–Wen model and a frequency-dependent dynamic module. A series of experiments are conducted to characterize the rate-dependent hysteresis of piezoelectric stack actuators under sinusoidal excitations at a range of 1 to 20 Hz. The experimental results verify the validity of the modified model. The modified Bouc–Wen model increases the complexity of Bouc–Wen hysteresis nonlinear differential equation, which brings difficulties to parameter identification. To identify the parameters of Bouc–Wen model, an improved hybrid differential evolution and Jaya (DE-Jaya) algorithm is introduced with a hybrid mutant operator and Jaya operator that tried to balance between convergence speed and solution accuracy. The improved algorithm is tested on benchmark functions and compared with other optimizations to prove its effectiveness. The comparison results show that hybrid DE-Jaya algorithm has better performance in convergence speed and solution accuracy. The identified discrete-time-modified Bouc–Wen model is used as the secondary path in a filtered-x variable step-size affine projection algorithm (FXVSSAPA), and experimental verifications are done on a micro-vibration control platform. The experimental results show that the FXVSSAPA algorithm can converge to the steady-state error faster and verify the effectiveness of the proposed discrete-time-modified Bouc–Wen model.
21 October 2024 in Journal of Low Frequency Noise, Vibration and Active Control
This study aims to enhance active vibration control in a cantilever beam using macro fiber composite (MFC) actuators. To address the challenge of accurately modeling the complex hysteresis behavior of MFC actuators, an advanced hysteresis modeling technique is employed, integrating a non-symmetric Bouc–Wen model with an Auto-Regressive model with eXogenous inputs (ARX). The parameter estimation of this model is optimized using an adaptive mutation factor, and multiple mutation strategy differential evolution (AmFMMDE) algorithm. Additionally, a Variable Step Size Filtered-x Least Mean Square (VSS-FxLMS) algorithm with step size adaptation based on normalized error change is utilized for effective vibration control. This approach shows promising potential for practical engineering applications requiring precise and efficient active vibration control.
18 November 2011 in IEEE Transactions on Applied Superconductivity
A 0.5 MVA/1 MJ superconducting magnetic energy storage system (SMES) has been installed in a superconducting power substation. The SMES is designed to compensate active power fluctuations, current harmonics and reactive power of the downstream load. The system configurations and control strategies are described. Experimental and field test results show that the proposed SMES can effectively improve the power quality of the power system.