Gas insulated switchgear equipment (GIS) is widely used in power system, and more attention has been paid to discharge defects than mechanical defects. However, since mechanical defects are a major cause of the failure in GIS, it is of great significance to carry out relevant research on mechanical defects. Detection and diagnosis methods of mechanical defects based on vibration signal are studied in this paper. Firstly, vibration mechanisms of GIS are analyzed. Due to structural differences between single phase insulated type GIS and three phase insulated type GIS, there are big differences in vibration mechanisms between the two types of GISs. Secondly, experimental research on mechanical defects is carried out based on a 110 kV GIS equipment and a self-developed vibration detection system; results show that mechanical defects can be diagnosed by analyzing signal amplitude, frequency spectrum and waveform distortion rate, and a large current is more beneficial for diagnosing mechanical defects. Lastly, field application has been carried out on 220 kV GIS equipment, and a poor contact defect is found, demonstrating that abnormal diagnosis can be realized by method proposed in this paper. Experimental research and field application demonstrate the feasibility and effectiveness of detection and diagnosis method for mechanical defects based on vibration signal and provide experience for subsequent engineering application.
Transient voltage generated in ultra-high voltage (UHV) transmission system has a severe impact on the insulation state of gas-insulated transmission lines (GIL). In order to monitor the transient voltage process occurring in UHV GIL during operation, this paper constructs a transient voltage ultra-wideband (UWB) online monitoring system based on capacitive voltage division. This system has been applied in an 1100 kilovolt (kV) GIL utility tunnel project. It can be used to analyze the characteristics of the recorded transient voltage waveforms for distinguishing different types of insulation failure. In this paper, through the case studies in time domain and time–frequency domain, the case of SF6 gap breakdown and that of post insulator flashover have differentiated characteristics in instantaneous frequency. Additionally, a case of secondary discharge is successfully estimated through the time–frequency distribution of the transient voltage. In order to find the malfunctioning chamber of GIL rapidly, a two-terminal TW-based fault location method based on this monitoring system is developed in this paper. The case study validates the locating accuracy which directly support for shortening the maintenance time of GIL.