(1) Multiple in vitro studies reported insufficient accuracy of intraoral scanners (IOSs) for complete-arch multiple implant impression. The aim of the study is to analyze the precision of three IOSs, PIC dental (Pic dental, Iditec North West SL), TRIOS 3 (3Shape), and True Definition (Midmark Corporation) and the influence of several factors in the edentulous complete maxillary and mandibular arch. (2) A fully edentulous patient with eight implants in the maxillary and in the mandibular jaw was selected. Five impressions were taken per system and arch. A suprastructure was designed on each digital working cast. The precision was analyzed comparing each of the 28 distances and seven relative angulations of the abutments of all the designed suprastructures. The descriptive statistics, the Student’s t-test, and the ANOVA test were used to analyze the data (α = 0.05). (3) Significant differences were observed when comparing the IOSs in some of the distances and angulations. (4) The increase in the distance between implants affected the precision of T and TD but not the PIC system. The type of arch did not affect the PIC precision, but the T and TD systems performed worse in the mandibular arch. The system with the best precision was the PIC, followed by TD, and then T.
Work-related stress is a major cause of health problems worldwide. Faculty in educational institutions, including universities, also face high levels of stress, which undoubtedly affects their performance, level of personal satisfaction and wellbeing, and the relationship with students. Training interventions based on embodied learning can promote self-knowledge, emotional regulation and stress reduction, thereby increasing levels of psychological well-being. The present pilot study analyzed the impact of body awareness training in 31 university teachers using a controlled, randomized pre-post experimental design, with two experimental groups and a control group (n = 10). The two interventions were: Hatha Yoga (n = 11) and Dance Movement Therapy/Body Mind Centering (n = 10), which we have termed Body Movement Awareness. Variables related to body awareness, mindfulness, wellbeing, life satisfaction and stress were measured using self-perception tests. Cortisol levels, heart rate variability and sleep quality were also analyzed. Finally, participants’ reflections were analyzed according to a qualitative approach. The results showed significant differences between the control group and the Hatha Yoga group in terms of stress reduction and wellbeing. The Body Movement Awareness group exhibited evidence of contributions on self-knowledge, communication and kinesthetic empathy, key elements in the educational field. Despite the inherent limitations of the study, the conclusions are encouraging and open new lines of research from embodied approaches that introduce creative movement and group experience as part of the process of emotional regulation and self-knowledge.
1 June 2016 in Journal of the Neurological Sciences
Background Different methods have been proposed to study skeletal muscle mass in sarcopenia diagnosis, although all have inherent drawbacks. The aim of this study was to evaluate the utility of muscle ultrasound in muscle assessment by studying its correlation with dual-energy x-ray absorptiometry (DXA) and calf circumference (CC), cut-off values for ultrasound-based detection of low muscle mass, and the correlation with muscle performance. Methods Fifty-seven participants older than 70 years, underwent a muscle ultrasound study, DXA, calf circumference (CC) and functional assessment. Ultrasound measurements were taken in the femoral quadriceps (transverse plane) and in the medial gastrocnemius (transverse and longitudinal planes). Muscle function was assessed by gait speed, Short Physical Performance Battery (SPPB) and grip strength. Results Median age was 78.9 years (IQR 74.9–81.9), and 33 were women (57.9%). We found good correlation between muscle thickness of gastrocnemius muscle in transverse and longitudinal plane and appendicular lean mass measured by DXA (r=0.546 and r=0.689 respectively) and good correlations between muscle thickness of gastrocnemius in transverse and longitudinal plane with CC (r=0.651 and r=0.447 respectively). The thickness of gastrocnemius medialis optimal cut-off points for low muscle mass were 18,5mm in the transverse plane (Sensitivity: 77,8%, Specificity: 77,1%), and 17.3mm in the longitudinal plane (Sensitivity: 100%, Specificity: 68.8%). Muscle thickness was also significantly correlated with gait speed, SPPB and grip strength. Conclusions Measures of gastrocnemius medialis thickness obtained by ultrasound are reliable and correlate well with DXA and CC values and muscle performance.