Sangmin Yi

Mr. Sangmin Yi

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
SCSeungwon Cho
Seungwon Cho
Soohwan ByunSoohwan Byun
Soohwan Byun
SYSangmin Yi
Sangmin Yi
WJWon-Seok JANG
Won-Seok JANG
JKJong-Cheol Kim
Jong-Cheol Kim
Byoung-Eun YangByoung-Eun Yang
Byoung-Eun Yang
Objective: Digital twins of adult Korean females were created as a tool to evaluate and compare the sagittal relationship between the maxillary central incisors and the forehead before and after orthodontic treatment. Methods: Digital twins were reconstructed for a total of 50 adult female patients using facial scans and cone-beam computed tomography (CBCT) images. The anteroposterior position of the maxillary central incisor and the forehead inclination were measured. Results: The control group presented a mean of 6.7 mm for the sagittal position and 17.5° for forehead inclination. The study group showed a mean of 9.3 mm for the sagittal position and 13.6° for forehead inclination. Most Korean females seeking orthodontic treatment had their maxillary central incisor anterior to the glabella. In contrast, fewer Korean females who completed their orthodontic treatments had their maxillary central incisor anterior to the glabella. Furthermore, patients who had completed the orthodontic treatment were more likely to have the maxillary central incisor between the forehead facial axis and glabella. Conclusion: The use of digital twins for three-dimensional (3D) analysis of the profile implies a high clinical significance. In addition, as the facial profile of Koreans is different from that of Caucasians, careful consideration should be made when setting treatment goals for the anteroposterior position of the maxillary central incisors.

24 August 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
SOSung Woon On
Sung Woon On
Sang-Yoon ParkSang-Yoon Park
Sang-Yoon Park
SYSangmin Yi
Sangmin Yi
IPIn-Young Park
In-Young Park
Soohwan ByunSoohwan Byun
Soohwan Byun
Byoung-Eun YangByoung-Eun Yang
Byoung-Eun Yang
Recombinant human bone morphogenetic protein-2 (rhBMP-2) has shown potential in maxillofacial surgery owing to its osteoinductive properties. However, concerns about its safety and high cost have limited its widespread use. This review presents the status of rhBMP-2 use in maxillofacial surgery, focusing on its clinical application, efficacy, safety, and limitations. Studies have demonstrated rhBMP-2’s potential to reduce donor site morbidity and increase bone height in sinus and ridge augmentation; however, it may not outperform autogenous bone grafts. In medication-related osteonecrosis of the jaw treatment, rhBMP-2 has been applied adjunctively with promising results, although its long-term safety requires further investigation. However, in maxillofacial trauma, its application is limited to the restoration of large defects. Safety concerns include postoperative edema and the theoretical risk of carcinogenesis. Although postoperative edema is manageable, the link between rhBMP-2 and cancer remains unclear. The limitations include the lack of an ideal carrier, the high cost of rhBMP-2, and the absence of an optimal dosing regimen. In conclusion, rhBMP-2 is a promising graft material for maxillofacial surgery. However, it has not yet become the gold standard owing to safety and cost concerns. Further research is required to establish long-term safety, optimize dosing, and develop better carriers.

29 April 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
RCRan-Yeong Cho
Ran-Yeong Cho
Soohwan ByunSoohwan Byun
Soohwan Byun
SYSangmin Yi
Sangmin Yi
HAHee-Ju Ahn
Hee-Ju Ahn
YNYoo-Sung Nam
Yoo-Sung Nam
Byoung-Eun YangByoung-Eun Yang
Byoung-Eun Yang
Background: Multi-dimensional facial imaging is increasingly used in hospital clinics. A digital twin of the face can be created by reconstructing three-dimensional (3D) facial images using facial scanners. Therefore, the reliability, strengths, and weaknesses of scanners should be investigated and approved; Methods: Images obtained from three facial scanners (RayFace, MegaGen, and Artec Eva) were compared with cone-beam computed tomography images as the standard. Surface discrepancies were measured and analyzed at 14 specific reference points; Results: All scanners used in this study achieved acceptable results, although only scanner 3 obtained preferable results. Each scanner exhibited weak and strong points because of differences in the scanning methods. Scanner 2 exhibited the best result on the left endocanthion; scanner 1 achieved the best result on the left exocanthion and left alare; and scanner 3 achieved the best result on the left exocanthion (both cheeks); Conclusions: These comparative analysis data can be used when creating digital twins through segmentation, selecting and merging data, or developing a new scanner to overcome all shortcomings.

Verified
Journal Article
Open access
PDF file
JRJiin Ryu
Jiin Ryu
Byoung-Eun YangByoung-Eun Yang
Byoung-Eun Yang
SYSangmin Yi
Sangmin Yi
HCHyo Geun Choi
Hyo Geun Choi
SOSung Woon On
Sung Woon On
Soohwan ByunSoohwan Byun
Soohwan Byun
This study aimed to evaluate the bone regeneration capacity of a customized alloplastic material and xenograft with recombinant human bone morphogenetic protein-2 (rhBMP-2). We prepared hydroxyapatite (HA)/tricalcium phosphate (TCP) pure ceramic bone blocks made using a 3D printing system and added rhBMP-2 to both materials. In eight beagle dogs, a total of 32 defects were created on the lower jaws. The defective sites of the negative control group were left untreated (N group; 8 defects), and those in the positive control group were filled with particle-type Bio-Oss (P group; 12 defects). The defect sites in the experimental group were filled with 3D-printed synthetic bone blocks (3D group; 12 defects). Radiographic and histological evaluations were performed after healing periods of 6 and 12 weeks and showed no significant difference in new bone formation and total bone between the P and 3D groups. The 3D-printed custom HA/TCP graft with rhBMP-2 showed bone regeneration effects similar to that of particulate Bio-Oss with rhBMP-2. Through further study and development, the application of 3D-printed customized alloplastic grafts will be extended to various fields of bone regeneration.

20 September 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
Soohwan ByunSoohwan Byun
Soohwan Byun
JSJoung-Hwa Seo
Joung-Hwa Seo
RCRanYeong Cho
RanYeong Cho
SYSangmin Yi
Sangmin Yi
LKLee-Kyoung Kim
Lee-Kyoung Kim
Byoung-Eun YangByoung-Eun Yang
Byoung-Eun Yang
(1) Background: The stability of implants plays a significant role in the success of osseointegration. The stability of the connection between the fixture and the abutment is one of the critical factors affecting osseointegration. When restoring multiple, non-parallel, and splinted implants, achieving a passive fit can be complicated and challenging. A new EZ post non-engaging abutment system of the BlueDiamond® (BD) implant allows a wide connection angle while achieving a passive prosthesis fit. This study aimed to confirm the new abutment system’s clinical applicability by evaluating its biomechanical characteristics using finite element analysis (FEA). (2) Methods: The implant-supported fixed three-unit dental prostheses model was reproduced for two groups of AnyOne® (AO) and BD implants using FEA. The loading conditions were a preload of 200 N in the first step and loads of 100 N (axial), 100 N (15°), or 30 N (45°) in the second step. (3) Results: The peak Von Mises stress (PVMS) value of the fixture in the BD group was more than twice that in the AO group. In contrast, the PVMS values of the abutment and abutment screws were lower in the BD group than in the AO group. The AO group revealed higher maximal principal stress (MPS) values than that of the BD group in the cortical bone, cancellous bone, and crown. The average stress of the outer surface of the abutment was lower in the AO group than in the BD group. The stress distribution for the inner surface of the fixture confirmed that the BD group displayed a lower stress distribution than the AO group under axial and 15° loads; however, the average stress was 1.5 times higher at the 45° load. The stress values of the entire surface where the cortical and cancellous bone were in contact with the fixture were measured. The AO group showed a higher stress value than the BD group in both cortical and cancellous bone. (4) Conclusions: In the AO group, the PVMS value of the fixture and the stress distribution at the contact surface between the fixture and the abutment were lower than those of the BD group, suggesting that the stability of the fixture would be high. However, due to the high stress in the fastening area of the abutment and abutment screw, the risk of abutment fracture in the AO group is higher than that of the BD group. Therefore, the new EZ post non-engaging abutment of the BD implant can be used without any problems in clinics, similar to the non-engaging abutment of the AO implant, which has been widely used in clinical practice.

27 February 2022 in Biology
Verified
Journal Article
Open access
PDF file
YLYou Na Lim
You Na Lim
Byoung-Eun YangByoung-Eun Yang
Byoung-Eun Yang
Soohwan ByunSoohwan Byun
Soohwan Byun
SYSangmin Yi
Sangmin Yi
SOSung Woon On
Sung Woon On
IPIn-Young Park
In-Young Park
Aim. To investigate the effect of changes in incisor tip, apex movement, and inclination on skeletal points A and B and characterize changes in skeletal points A and B to the soft tissue points A and B after incisor retraction in Angle Class I bimaxillary dentoalveolar protrusion. Methods. Twenty-two patients with Angle Class I bimaxillary dentoalveolar protrusion treated with four first premolar extractions were included in this study. The displacement of skeletal and soft tissue points A and B was measured using cone-beam computed tomography (CBCT) using a three-dimensional coordinate system. The movement of the upper and lower incisors was also measured using CBCT-synthesized lateral cephalograms. Results. Changes in the incisal tip, apex, and inclination after retraction did not significantly affect the position of points A and B in any direction (x, y, z). Linear regression analysis showed a statistically significant relationship between skeletal point A and soft tissue point A on the anteroposterior axis (z). Skeletal point A moved forward by 0.07 mm, and soft tissue point A moved forward by 0.38 mm, establishing a ratio of 0.18: 1 (r = 0.554, p < 0.01). Conclusion. The positional complexion of the skeletal points A and B was not directly influenced by changes in the incisor tip, apex, and inclination. Although the results suggest that soft tissue point A follows the anteroposterior position of skeletal point A, its clinical significance is suspected. Thus, hard and soft tissue analysis should be considered in treatment planning.