M. Gabriela Almeida

Ms. M. Gabriela Almeida


Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2013 in Applied Microbiology and Biotechnology
Verified
Journal Article
Closed access
PDF file
Patrícia BrancoPatrícia Branco
Patrícia Branco
DFDiana Francisco
Diana Francisco
CCChristophe Chambon
Christophe Chambon
MHMichel Hebraud
Michel Hebraud
NANils Arneborg
Nils Arneborg
HAHelena Albergaria
Helena Albergaria

1 February 2016 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
LSLidia Santos
Lidia Santos
CSCelia Silveira
Celia Silveira
EEElamurugu Elangovan
Elamurugu Elangovan
JNJoana P. Neto
Joana P. Neto
Daniela NunesDaniela Nunes
Daniela Nunes
Elvira FortunatoElvira Fortunato
Elvira Fortunato

1 May 2003 in Journal of Biological Chemistry
Verified
Journal Article
Open access
PDF file
CCCarlos A. Cunha
Carlos A. Cunha
SMSofia Macieira
Sofia Macieira
JDJoão M. Dias
João M. Dias
MAM. Gabriela Almeida
M. Gabriela Almeida
LGLuísa L. Gonçalves
Luísa L. Gonçalves
MRMaria Joao Romão
Maria Joao Romão
The gene encoding cytochrome cnitrite reductase (NrfA) from Desulfovibrio desulfuricansATCC 27774 was sequenced and the crystal structure of the enzyme was determined to 2.3-Å resolution. In comparison with homologous structures, it presents structural differences mainly located at the regions surrounding the putative substrate inlet and product outlet, and includes a well defined second calcium site with octahedral geometry, coordinated to propionates of hemes 3 and 4, and caged by a loop non-existent in the previous structures. The highly negative electrostatic potential in the environment around hemes 3 and 4 suggests that the main role of this calcium ion may not be electrostatic but structural, namely in the stabilization of the conformation of the additional loop that cages it and influences the solvent accessibility of heme 4. The NrfA active site is similar to that of peroxidases with a nearby calcium site at the heme distal side nearly in the same location as occurs in the class II and class III peroxidases. This fact suggests that the calcium ion at the distal side of the active site in the NrfA enzymes may have a similar physiological role to that reported for the peroxidases.

14 May 2018 in Critical Reviews in Analytical Chemistry
Verified
Journal Article
Closed access
TMTiago Monteiro
Tiago Monteiro
MAM. Gabriela Almeida
M. Gabriela Almeida
Worldwide legislation is driving the development of novel and highly efficient analytical tools for assessing the composition of every material that interacts with Consumers or Nature. The biosensor technology is one of the most active R&D domains of Analytical Sciences focused on the challenge of taking analytical chemistry to the field. Electrochemical biosensors based on redox enzymes, in particular, are highly appealing due to their usual quick response, high selectivity and sensitivity, low cost and portable dimensions. This review paper aims to provide an overview of the most important advances made in the field since the proposal of the first biosensor, the well-known hand-held glucose meter. The first section addresses the current needs and challenges for novel analytical tools, followed by a brief description of the different components and configurations of biosensing devices, and the fundamentals of enzyme kinetics and amperometry. The following sections emphasize on enzyme-based amperometric biosensors and the different stages of their development.

1 September 2007 in Electrochemistry Communications
Verified
Journal Article
Closed access
HCH. Chen
H. Chen
CMC. Mousty
C. Mousty
SCS. Cosnier
S. Cosnier
CSCelia Silveira
Celia Silveira
Jose J. G. MouraJose J. G. Moura
Jose J. G. Moura
MAM. Gabriela Almeida
M. Gabriela Almeida

28 September 2016 in Biosensors
Verified
Journal Article
Open access
PDF file
CSCelia Silveira
Celia Silveira
TMTiago Monteiro
Tiago Monteiro
MAM. Gabriela Almeida
M. Gabriela Almeida
From the bench-mark work on microfluidics from the Whitesides’s group in 2007, paper technology has experienced significant growth, particularly regarding applications in biomedical research and clinical diagnostics. Besides the structural properties supporting microfluidics, other advantageous features of paper materials, including their versatility, disposability and low cost, show off the great potential for the development of advanced and eco-friendly analytical tools. Consequently, paper was quickly employed in the field of electrochemical sensors, being an ideal material for producing custom, tailored and miniaturized devices. Stencil-, inkjet-, or screen-printing are the preferential techniques for electrode manufacturing. Not surprisingly, we witnessed a rapid increase in the number of publications on paper based screen-printed sensors at the turn of the past decade. Among the sensing strategies, various biosensors, coupling electrochemical detectors with biomolecules, have been proposed. This work provides a critical review and a discussion on the future progress of paper technology in the context of miniaturized printed electrochemical biosensors.