The grid voltage, especially under unbalanced and harmonically distorted grid conditions, often distorts the injected currents of grid-connected inverters. To address this problem, a robust control scheme of grid-connected inverters is presented in this paper. The proposed scheme is achieved by an internal model (IM)-based current controller and a robust phase-locked loop (PLL) scheme. The robust PLL scheme employs open-loop filtering technique to offer exact steady-state performance as well as fast transient response. The IM-based current controller is stabilized using the linear matrix inequality approach to optimize the feedback gains, and implemented in the synchronous reference frame to reduce computational efforts. A state estimator is also introduced into current controller for the purpose of reducing the number of current sensors, which are often required in state feedback controller to damp the unstable dynamics of LCL filters. The validity of the proposed control scheme is demonstrated through comparative simulations and experimental results using a prototype grid-connected inverter.
This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. The main challenge associated with the grid-connected inverter in distributed generation (DG) systems is to maintain the harmonic contents in output current below the specified values even when the grid is subject to uncertain disturbances such as harmonic distortion. To overcome such a challenge, an improved current control scheme is proposed for a grid-connected inverter, in which the fundamental and harmonic currents are independently controlled by a proportional-integral (PI) decoupling controller and a predictive basis controller, respectively. The controller design approach is based on the model decomposition method, where the measured inverter currents and grid voltages are divided into the fundamental and harmonic components by means of moving average filters (MAFs). Moreover, to detect the angular displacement and angular frequency with better accuracy, even in the presence of the grid disturbance, the MAF is also introduced to implement an enhanced phase-lock loop (PLL) structure. Theoretical analyses as well as comparative simulation results demonstrate that the proposed control scheme can effectively compensate the uncertainties caused by the grid voltages with fast transient response. To validate the feasibility of the proposed scheme, the whole control algorithms are implemented on 2 kVA three-phase grid-connected inverter system using 32-bit floating-point DSP TMS320F28335. As a result, the proposed scheme is an attractive way to control a grid-connected inverter under adverse grid conditions.
1 June 2020 in IEEE Transactions on Power Electronics
Inductive-capacitive-inductive (LCL)-type filters are currently preferred as a replacement for L-type filters in distributed generation (DG) power systems, due to their superior harmonic attenuation capability. However, the third-order dynamics introduced by LCL filters pose a challenge to design a satisfactory controller for such a system. Conventionally, an LCL-filtered grid-connected inverter can be effectively controlled by using a full-state feedback control. However, this control approach requires the measurement of all system state variables, which brings about more complexity for the inverter system. To address this issue, this paper presents a systematic procedure to design an observer-based integral state feedback control for a LCL-filtered grid-connected inverter in the discrete-time domain. The proposed control scheme consists of an integral state feedback controller and a full-state observer which uses the control input, grid-side currents, and grid voltages to predict all the system state variables. Therefore, only the grid-side current sensors and grid voltage sensors are required to implement the proposed control scheme. Due to the discrete-time integrator incorporated in the state feedback controller, the proposed control scheme ensures both the reference tracking and disturbance rejection performance of the inverter system in a practical and simple way. As a result, superior control performance can be achieved by using the reduced number of sensors, which significantly reduces the cost and complexity of the LCL-filtered grid-connected inverter system in DG applications. To verify the practical usefulness of the proposed control scheme, a 2 kW three-phase prototype grid-connected inverter has been constructed, and the proposed control system has been implemented based on 32-bit floating-point digital signal processor (DSP) TMS320F28335. The effectiveness of the proposed scheme is demonstrated through the comprehensive simulation and experimental results.
27 April 2021 in IEEE Transactions on Industry Applications
The increasing participation of renewables in power systems has forced system operators to strengthen grid codes requiring renewable power plants (RPPs) to provide fast frequency support such as inertia response and power oscillation damping. To cope with such new requirements, this article proposes the implementation of a virtual synchronous power plant controller (VSPPC) for RPPs. The VSPPC takes the most from emulating the behavior of a synchronous generator, especially in the case of grid events, as it permits emulating inertia and provides power oscillation damping capabilities. If compared with conventional control schemes, the main advantage of the VSPPC lays in the fact that it does not require to implement any modification in the existing controllers of the plant's converters, which are often controlled as grid-following generation units. This feature makes VSPPC attractive for incorporating advanced grid supporting functionalities in utility-scale RPPs. In this work, the main principles behind the VSPPC and comparative analysis based on simulation and experimental results are provided to validate its performance.
30 August 2021 in IEEE Transactions on Industry Applications
The advent of renewable energy has posed difficulties in the operation of power systems whose net inertia is becoming critically low. To face such challenges, grid-forming power has been one of the potential solutions pursued by the industry and research community. Although promising, grid-forming power converters are still immature for mass deployment in power systems. In the meanwhile, an enormous amount of grid-following power converters has been underexploited when it comes to grid-supporting functionalities. Therefore, this article proposes an external inertia emulation controller (eIEC) for grid-following power converter to provide frequency support to the grid. For the purpose of minimizing installation efforts and resources, the controller is designed in such a way that it can be implemented in an external controller communicating with the grid-following power converter via an industrial communication link. This article also investigates the effect of communication delay on the stability performance of the proposed controller. In addition to the detailed analysis, hardware-in-the-loop experiments are also carried out to validate the proposed eIEC.