Jose Ignacio Candela

Jose Ignacio Candela

Auto-generated profile, based on publicly available information

Jose Ignacio Candela

Renewable Electrical Energy Systems (SEER), Technical University of Catalonia, Terrassa, Spain

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2007 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Pedro RodriguezPedro Rodriguez
Pedro Rodriguez
Josep PouJosep Pou
Josep Pou
JBJoan Bergas
Joan Bergas
JCJ. Ignacio Candela
J. Ignacio Candela
RBRolando P. Burgos
Rolando P. Burgos
DBDushan Boroyevich
Dushan Boroyevich
This paper deals with a crucial aspect in the control of grid-connected power converters, i.e., the detection of the fundamental-frequency positive-sequence component of the utility voltage under unbalanced and distorted conditions. Specifically, it proposes a positive-sequence detector based on a new decoupled double synchronous reference frame phase-locked loop (DDSRF-PLL), which completely eliminates the detection errors of conventional synchronous reference frame PLL's (SRF-PLL). This is achieved by transforming both positive- and negative-sequence components of the utility voltage into the double SRF, from which a decoupling network is developed in order to cleanly extract and separate the positive- and negative-sequence components. The resultant DDSRF-PLL conducts then to a fast, precise, and robust positive-sequence voltage detection even under unbalanced and distorted grid conditions. The paper presents a detailed description and derivation of the proposed detection method, together with an extensive evaluation using simulation and experimental results from a digital signal processor-based laboratory prototype in order to verify and validate the excellent performance achieved by the DDSRF-PLL

12 April 2010 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Open access
Pedro RodriguezPedro Rodriguez
Pedro Rodriguez
ALAlvaro Luna
Alvaro Luna
ICIgnacio Candela
Ignacio Candela
RMRamon Mujal
Ramon Mujal
Remus TeodorescuRemus Teodorescu
Remus Teodorescu
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
This paper presents a new multiresonant frequency-adaptive synchronization method for grid-connected power converters that allows estimating not only the positive- and negative-sequence components of the power signal at the fundamental frequency but also other sequence components at other harmonic frequencies. The proposed system is called MSOGI-FLL since it is based on both a harmonic decoupling network consisting of multiple second-order generalized integrators (MSOGIs) and a frequency-locked loop (FLL), which makes the system frequency adaptive. In this paper, the MSOGI-FLL is analyzed for single- and three-phase applications, deducing some key expressions regarding its stability and tuning. Moreover, the performance of the MSOGI-FLL is evaluated by both simulations and experiments to show its capability for detecting different harmonic components in a highly polluted grid scenario.

1 June 2006
Verified
Conference Paper
Closed access
Pedro RodriguezPedro Rodriguez
Pedro Rodriguez
Remus TeodorescuRemus Teodorescu
Remus Teodorescu
ICI. Candela
I. Candela
ATA. V. Timbus
A. V. Timbus
MLM. Liserre
M. Liserre
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg

24 June 2014 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Kumars RouzbehiKumars Rouzbehi
Kumars Rouzbehi
AMArash Miranian
Arash Miranian
JCJose Ignacio Candela
Jose Ignacio Candela
Alvaro LunaAlvaro Luna
Alvaro Luna
Pedro RodriguezPedro Rodriguez
Pedro Rodriguez
This paper proposes a generalized voltage droop (GVD) control strategy for dc voltage control and power sharing in voltage source converter (VSC)-based multiterminal dc (MTDC) grids. The proposed GVD control is implemented at the primary level of a two-layer hierarchical control structure of the MTDC grid, and constitutes an alternative to the conventional voltage droop characteristics of voltage-regulating VSC stations, providing higher flexibility and, thus, controllability to these networks. As a difference with other methods, the proposed GVD control strategy can be operated in three different control modes, including conventional voltage droop control, fixed active power control, and fixed dc voltage control, by adjusting the GVD characteristics of the voltage-regulating converters. Such adjustment is carried out in the secondary layer of the hierarchical control structure. The proposed strategy improves the control and power-sharing capabilities of the conventional voltage droop, and enhances its maneuverability. The simulation results, obtained by employing a CIGRE B4 dc grid test system, demonstrate the efficiency of the proposed approach and its flexibility in active power sharing and power control as well as voltage control. In these analysis, it will be also shown how the transitions between the operating modes of the GVD control does not give rise to active power oscillations in the MTDC grids.

13 January 2015 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Alvaro LunaAlvaro Luna
Alvaro Luna
JRJoan Rocabert
Joan Rocabert
JCJ. Ignacio Candela
J. Ignacio Candela
JHJuan Ramon Hermoso
Juan Ramon Hermoso
Remus TeodorescuRemus Teodorescu
Remus Teodorescu
Pedro RodriguezPedro Rodriguez
Pedro Rodriguez
The actual grid code requirements for the grid connection of distributed generation systems, mainly wind and photovoltaic (PV) systems, are becoming very demanding. The transmission system operators (TSOs) are especially concerned about the low-voltage-ride-through requirements. Solutions based on the installation of STATCOMs and dynamic voltage regulators (DVRs), as well as on advanced control functionalities for the existing power converters of distributed generation plants, have contributed to enhance their response under faulty and distorted scenarios and, hence, to fulfill these requirements. In order to achieve satisfactory results with such systems, it is necessary to count on accurate and fast grid voltage synchronization algorithms, which are able to work under unbalanced and distorted conditions. This paper analyzes the synchronization capability of three advanced synchronization systems: the decoupled double synchronous reference frame phase-locked loop (PLL), the dual second order generalized integrator PLL, and the three-phase enhanced PLL, designed to work under such conditions. Although other systems based on frequency-locked loops have also been developed, PLLs have been chosen due to their link with dq0 controllers. In the following, the different algorithms will be presented and discretized, and their performance will be tested in an experimental setup controlled in order to evaluate their accuracy and implementation features.

1 November 2008
Verified
Conference Paper
Closed access
Pedro RodriguezPedro Rodriguez
Pedro Rodriguez
ALA. Luna
A. Luna
ICI. Candela
I. Candela
Remus TeodorescuRemus Teodorescu
Remus Teodorescu
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
This paper presents a new frequency-adaptive synchronization method for grid-connected power converters which allows estimating not only the positive- and negative-sequence components of the power signal at the fundamental frequency, but also other sequence components at higher frequencies. The proposed system is called the MSOGI-FLL since it is based on a decoupled network consisting of multiple second order generalized integrators (MSOGI) which are frequency-adaptive by using a frequency-locked loop (FLL). In this paper, the MSOGI-FLL is analyzed and its performance is evaluated by both simulations and experiments.