Armands Ancans

Mr. Armands Ancans

Institute of Electronics and Computer Science
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Armands AncansArmands Ancans
Armands Ancans
Modris GreitānsModris Greitāns
Modris Greitāns
RCRicards Cacurs
Ricards Cacurs
BBBeāte Banga
Beāte Banga
ARArtis Rozentals
Artis Rozentals
This paper presents a wearable wireless system for measuring human body activities, consisting of small inertial sensor nodes and the main hub for data transmission via Bluetooth for further analysis. Unlike optical and ultrasonic technologies, the proposed solution has no movement restrictions, such as the requirement to stay in the line of sight, and it provides information on the dynamics of the human body’s poses regardless of its location. The problem of the correct placement of sensors on the body is considered, a simplified architecture of the wearable clothing is described, an experimental set-up is developed and tests are performed. The system has been tested by performing several physical exercises and comparing the performance with the commercially available BTS Bioengineering SMART DX motion capture system. The results show that our solution is more suitable for complex exercises as the system based on digital cameras tends to lose some markers. The proposed wearable sensor clothing can be used as a multi-purpose data acquisition device for application-specific data analysis, thus providing an automated tool for scientists and doctors to measure patient’s body movements.

5 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ESElise Saoutieff
Elise Saoutieff
TPTiziana Polichetti
Tiziana Polichetti
LJLaurent Jouanet
Laurent Jouanet
AFAdrien Faucon
Adrien Faucon
AVAudrey Vidal
Audrey Vidal
AIAdrian Ionescu
Adrian Ionescu
The low-power sensing platform proposed by the Convergence project is foreseen as a wireless, low-power and multifunctional wearable system empowered by energy-efficient technologies. This will allow meeting the strict demands of life-style and healthcare applications in terms of autonomy for quasi-continuous collection of data for early-detection strategies. The system is compatible with different kinds of sensors, able to monitor not only health indicators of individual person (physical activity, core body temperature and biomarkers) but also the environment with chemical composition of the ambient air (NOx, COx, NHx particles) returning meaningful information on his/her exposure to dangerous (safety) or pollutant agents. In this article, we introduce the specifications and the design of the low-power sensing platform and the different sensors developed in the project, with a particular focus on pollutant sensing capabilities and specifically on NO2 sensor based on graphene and CO sensor based on polyaniline ink.

1 June 2019
Verified
Conference Paper
Closed access
Armands AncansArmands Ancans
Armands Ancans
JOJuris Ormanis
Juris Ormanis
RCRicards Cacurs
Ricards Cacurs
Modris GreitānsModris Greitāns
Modris Greitāns
ESElise Saoutieff
Elise Saoutieff
SBSebastien Boisseau
Sebastien Boisseau
Bluetooth Low Energy (BLE) is a promising 2.4 GHz technology for Body Area Networks (BAN) in health care and lifestyle applications. However, the global increase of wireless devices using the crowded spectrum in the 2.4 GHz frequency band can create coexistence issues. This work studies the performance of BLE in environments with multiple BLE devices. An experimental setup consisting of 10 BLE nodes is used to measure BLE application throughput with different connection parameters and under different interference sources, such as other BLE devices and WiFi. The results quantify the decrease of the application throughput and the influence of BLE connection parameters in the experimental settings, as well as suggest parameter values suitable for densely deployed environments.

Verified
Journal Article
Open access
PDF file
Armands AncansArmands Ancans
Armands Ancans
Modris GreitānsModris Greitāns
Modris Greitāns
SKSandis Kaģis
Sandis Kaģis
We introduce a novel wired communication approach for interactive wearable systems, employing a single signal wire and innovative group addressing protocol to reduce overhead. While wireless solutions dominate body sensor networks, wired approaches offer advantages for interactive applications that require low latency, high reliability, and communication with high-density nodes; yet they have been less explored in the context of wearable systems. Many commercial products use wired connections without disclosing technical details, limiting broader adoption. To address this gap, we present and test a new group addressing protocol implemented using Universal Asynchronous Receiver–Transmitter (UART) hardware, disclosing frame diagrams and node architectures. We developed a prototype interactive jacket with nine sensor/actuator nodes connected via three wires for power supply and data transmission to a wireless gateway. Mathematical analysis showed an overhead reduction of approximately 50% compared to traditional individual addressing. Our solution is the most wire-efficient among wired interactive wearable systems reviewed in the literature, using only one signal wire; other methods require at least two wires and often have overlapping topologies. Performance experimental evaluation revealed a total feedback delay of 2.27 ms and a maximum data frame rate of 435.4 Hz, comparable to the best-performing products and leaving room for twice the performance calculated theoretically. These results indicate that the proposed approach is suitable for interactive wearable systems, both for real-time applications and high-resolution data acquisition.

13 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
AKAleksandrs Kalinovskis
Aleksandrs Kalinovskis
VSVsevolods Stepanovs
Vsevolods Stepanovs
Armands AncansArmands Ancans
Armands Ancans
Atis ElstsAtis Elsts
Atis Elsts
Riga Event Timers have the ability to measure the interval between events with high resolution, on the order of picoseconds. However, they have several drawbacks, such as sensitivity to environmental temperature changes and an inability to capture the amplitude of the events. In this work, we present the ETAM: a next generation Event Timer. Its innovative features include adaptive correction of measurement errors based on an internal temperature sensor, and integrated peak-detector circuit to determine the amplitude of nanosecond-duration pulses. Evaluation shows that the ETAM has high thermal stability with a root mean square error (RMSE) of <3 ps in a temperature range between 0 and +40 °C, and accurate event amplitude measurement capability, with <2.3 mV RMSE in the 100–1000 mV range. These improvements allow the ETAM to be used in satellite laser ranging, optical time-domain reflectometry, and other field applications that require temperature- and amplitude-based time correction in addition to high robustness, performance, and stability.

1 December 2022 in Automatic Control and Computer Sciences
Verified
Journal Article
Closed access
PDF file
VAVladimir Aristov
Vladimir Aristov
Armands AncansArmands Ancans
Armands Ancans
For the classical peak detector built on modern electronic components and designed to measure the amplitude of nanosecond pulses, an equivalent circuit, wh