Summary Objective: Evaluation of the bending properties in one direction of three titanium polyaxial locking plate systems. Materials and methods: The Polyaxial Advanced Locking System (PAX®) straight plate (PAX SP), the PAX® reconstruction plate (PAX RP), and the VetLOX reconstruction plates (VetLOX) were evaluated individually and as constructs applied to a bone model simulating a fracture gap and compared using a two-way analysis of variance and Tukey posthoc analysis. Results: The PAX SP had the highest values of bending stiffness, bending structural stiffness and bending strength. When tested as plates alone, the PAX RP and VetLOX showed no differences with regard to bending stiffness and bending structural stiffness, whilst the PAX RP had significantly higher strength. The PAX RP construct had significantly higher bending stiffness, bending structural stiffness and bending strength than the VetLOX construct. Clinical relevance: The PAX RP and VetLOX reconstruction plates are much more likely to fail when used as bridging implants, thus adjunct support is needed. The lower bending strength of the VetLOX reconstruction plates suggests it should not be used in fractures under high loads.
The aim of this study was to report the surgical treatment of stifle joint luxation through temporary immobilization of the joint with locking plates in a cat. Stifle joint was immobilized using a temporary trans-articular locking plate applied medially. Return to function was assessed by physical and radiographic follow-up examinations. The cat had good return to function despite a reduction in range of motion. Moderate chronic gonarthritis developed, as seen radiographically. Under the limitation of this single case, temporary trans-articular plating may be considered as useful method for the treatment of long-standing, severely displaced stifle joint luxations in cats.
The aim of this study is to report the results and to review the outcome of 14 cases of Y-T humeral fractures repair using paired polyaxial locking system (PAX) plates through a combined medial and lateral approach. Fourteen consecutive dogs, with traumatic humeral Y-T fractures, met the inclusion criteria. This study includes signalment, preoperative radiographs, type of implants, radiographic bone healing assessment, complications, range of motion (ROM) of the elbow and limb function evaluated at 120 days after surgery. Postoperative radiographs revealed adequate anatomic reconstruction, and in all cases, bone healing has been achieved. No implant failure was observed. Functional outcome was excellent in 7 dogs (no lameness and preserved ROM), good in 4 (slight lameness and moderate ROM reduction) and discrete in 2 (mild lameness and severe ROM reduction). Complications were encountered in 2/14 patients with implant-associated infection resolved after long-term antibiotic treatment and implant removal. The PAX system is shown to be a valid alternative for the treatment of Y-T humeral fractures, offering the benefit of polyaxial insertion of locking screws. The possibility of angle locking screws is helpful in the distal humeral bicondylar fractures, providing additional options for screw placement in juxtarticular fractures, avoiding fracture lines or other implants.