Filippo Maria Martini

Prof. Filippo Maria Martini


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2017 in Veterinary and Comparative Orthopaedics and Traumatology
Verified
Journal Article
Closed access
PDF file
FLFilippo Lusetti
Filippo Lusetti
ABAndrea Bonardi
Andrea Bonardi
CEChadi Eid
Chadi Eid
ABAnna Brandstetter De Bellesini
Anna Brandstetter De Bellesini
FMFilippo Maria Martini
Filippo Maria Martini
Summary: Objectives: The aim of the study was to describe the differences in pelvic limb alignment between healthy purebred English Bulldogs and those with medial patellar luxation through the measurement of femoral and tibial angles on computed tomography images in multiplanar reconstruction modality (MPRCT).Methods: Twenty-one purebred English Bulldogs were included and divided into two groups: one including healthy dogs (15 limbs) and the other including those with medial patellar luxation (24 limbs). Three different observers used MPR-CT to measure the following angles: anatomical lateral proximal femoral angle (aLPFA), anatomical lateral distal femoral angle (aLDFA), mechanical lateral proximal femoral angle (mLPFA), mechanical lateral distal femoral angle (mLDFA), angle of inclination of the femoral neck (AI), angle of anteversion (AA), mechanical medial proximal tibial angle (mMPTA), mechanical medial distal tibial angle (mMDTA), mechanical caudal distal tibial angle (mCdDTA), mechanical caudal proximal tibial angle (mCdPTA), and the tibial torsion angle (TTA). A Mann-Whitney U test was used to compare each variable in both groups.Results: The values for aLDFA and mLDFA in the medial patellar luxation population were significantly increased compared to healthy subjects (p <0.05). No significant differences were observed for the other variables.Clinical significance: In our population, an increased distal femoral varus was associated with medial patellar luxation. Our results could be useful to determine whether or not angular deformity of the femur is present and help determine the degree of correction necessary to restore alignment.ORCID iD:FMM: http://orcid.org/0000-0001-9615-2540

1 December 2017 in International Journal of Veterinary Science and Medicine
Verified
Journal Article
Open access
FMFilippo Maria Martini
Filippo Maria Martini
ABAnna Brandstetter de Bellesini
Anna Brandstetter de Bellesini
AMAlda Miolo
Alda Miolo
LCLaura Del Coco
Laura Del Coco
Francesco Paolo FanizziFrancesco Paolo Fanizzi
Francesco Paolo Fanizzi
ACANTONIO CROVACE
ANTONIO CROVACE
Canine cranial cruciate ligament rupture (CrCLR) is a very common pathology. Surgical stabilization is the first choice treatment, although it does not fully eliminate the increased risk of osteoarthritis. This preliminary study was carried out to explore whether a newly formulated joint health supplement would benefit metabolic, clinical and radiographic changes in dogs with CrCLR surgically treated with tibial plateau leveling osteotomy (TPLO). Besides chondroitin sulfate and glucosamine hydrochloride, the studied supplement contained anti-inflammatory and antioxidant ingredients, the main ones being N-palmitoyl-D-glucosamine (Glupamid®) and quercetin. It was thus intended to target not only chondrodegenerative components of osteoarthritis, but also post-injury inflammatory response and oxidative stress of joint tissues. Thirteen dogs underwent TPLO and were randomly allocated to treatment (n = 6) and control groups (n = 7), the former receiving the joint supplement for 90 days. Lameness and radiographic osteoarthritis changes were scored before (i.e., baseline) and at 30 and 90 days post-surgery. Synovial fluid samples were collected from injured stifles at the same time points. Levels of representative metabolites were measured by proton nuclear magnetic resonance spectroscopy in a blinded fashion. In the metabolomic analysis, special attention was paid to lactate, due to its emerging recognition as a key marker of inflammation. In the last time period (from the 30th to the 90th day), lameness improved by a factor of 2.3 compared to control dogs. No significant difference was observed in the radiographic osteoarthritis score between groups. In the first postoperative month, lactate and creatine levels significantly dropped in treated compared to control dogs. Compared to surgery alone, combining the joint supplement with TPLO resulted in a trend to a better clinical outcome in the later time interval but did not influence osteoarthritis radiographic progression. A significantly better rebalance of joint microenvironment in the early time interval (baseline - 30 days) was shown by metabolomic analysis, thus suggesting that the study supplement could limit ongoing inflammatory responses.

12 August 2024 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
FLFabio Leonardi
Fabio Leonardi
BSBarbara Simonazzi
Barbara Simonazzi
FMFilippo Maria Martini
Filippo Maria Martini
Pasquale D'AngeloPasquale D'Angelo
Pasquale D'Angelo
Ruben ForestiRuben Foresti
Ruben Foresti
MBMaddalena Botti
Maddalena Botti
In recent years, there has been a growing interest in 3D printing technology within the field of bioengineering. This technology offers the ability to create devices with intricate macro- and micro-geometries, as well as specific models. It has particularly gained attention for its potential in personalized medicine, allowing for the production of organ or tissue models tailored to individual patient needs. Further, 3D printing has opened up possibilities to manufacture structures that can substitute, complement, or enhance damaged or dysfunctional organic parts. To apply 3D printing in the medical field, researchers have studied various materials known as biomaterials, each with distinct chemical and physical characteristics. These materials fall into two main categories: hard and soft materials. Each biomaterial needs to possess specific characteristics that are compatible with biological systems, ensuring long-term stability and biocompatibility. In this paper, we aim to review some of the materials used in the biomedical field, with a particular focus on those utilized in veterinary medicine and ophthalmology. We will discuss the significant findings from recent scientific research, focusing on the biocompatibility, structure, applicability, and in vitro and in vivo biological characteristics of two hard and four soft materials. Additionally, we will present the current state and prospects of veterinary ophthalmology.

9 June 2025 in Research in Veterinary Science
Verified
Journal Article
Open access
MAMelania Andrani
Melania Andrani
PBPaolo Borghetti
Paolo Borghetti
RSRoberta Saleri
Roberta Saleri
BSBarbara Simonazzi
Barbara Simonazzi
VCValeria Cavalli
Valeria Cavalli
FMFilippo Maria Martini
Filippo Maria Martini
Veterinary and human biomedical research is increasingly oriented towards the development of biocompatible implantable devices capable of supporting tissue regeneration and the development of controlled release systems. Kapton®, a polyimide known for its thermal and mechanical properties, shows potential in tissue regeneration, but its interaction with cartilage cells has not been explored in depth. This study aims to evaluate the biocompatibility, cytotoxicity and chondrocyte response on plastic materials, including polyester, polystyrene and Kapton®, by studying cell proliferation (MTT assay), morphology (optical microscopy), oxidative stress (NO and ROS assay), wound healing capacity (scratch assay) and differentiation (gene expression of specific markers), as well as immune activity in real-time qPCR. The results demonstrate that over time Kapton® supports chondrocyte adhesion, viability and proliferation in a similar manner to polystyrene (PS). Instead, the migration test on Kapton® shows wound closure approximately 3.5-fold slower at 24 h and 4d compared to PS attributable to the surface properties of the material. Furthermore, its non-toxicity is confirmed with a reduced and non-significant induction of oxidative stress. Instead, polyimide maintains the chondrocyte morphology without dedifferentiation towards the fibroblastic phenotype observed with significant differences in the expression of differentiation markers (Col2, ACAN, SOX6 and SOX9) compared to polystyrene. The stable expression of IL6 confirms the absence of significant inflammatory signals. These results confirmed the chondro-inductive activity of Kapton® and point out the potential of this material as substrate for cartilage tissue engineering and regenerative medicine due to the preserved involvement of chondrocyte phenotype in cartilage extracellular matrix synthesis.

22 June 2022 in Veterinary Sciences
Verified
Journal Article
Open access
PDF file
FMFilippo Maria Martini
Filippo Maria Martini
PBPaolo Boschi
Paolo Boschi
FLFilippo Lusetti
Filippo Lusetti
CEChadi Eid
Chadi Eid
ABAndrea Bonardi
Andrea Bonardi
The aim of this study is to report the results and to review the outcome of 14 cases of Y-T humeral fractures repair using paired polyaxial locking system (PAX) plates through a combined medial and lateral approach. Fourteen consecutive dogs, with traumatic humeral Y-T fractures, met the inclusion criteria. This study includes signalment, preoperative radiographs, type of implants, radiographic bone healing assessment, complications, range of motion (ROM) of the elbow and limb function evaluated at 120 days after surgery. Postoperative radiographs revealed adequate anatomic reconstruction, and in all cases, bone healing has been achieved. No implant failure was observed. Functional outcome was excellent in 7 dogs (no lameness and preserved ROM), good in 4 (slight lameness and moderate ROM reduction) and discrete in 2 (mild lameness and severe ROM reduction). Complications were encountered in 2/14 patients with implant-associated infection resolved after long-term antibiotic treatment and implant removal. The PAX system is shown to be a valid alternative for the treatment of Y-T humeral fractures, offering the benefit of polyaxial insertion of locking screws. The possibility of angle locking screws is helpful in the distal humeral bicondylar fractures, providing additional options for screw placement in juxtarticular fractures, avoiding fracture lines or other implants.

21 August 2008 in Veterinary Research Communications
Verified
Journal Article
Open access
PDF file
ABA. F. Botazzoli
A. F. Botazzoli
FFF. Ferraresi
F. Ferraresi
OTO. Travetti
O. Travetti
FMFilippo Maria Martini
Filippo Maria Martini
CMC. M. Mortellaro
C. M. Mortellaro
MGMauro Di Giancamillo
Mauro Di Giancamillo
Elbow dysplasia is an invalidating pathology with a not yet entirely clarified etiology, that implies a congenital and/or herditary-familiar nature, showing a particularly elevated incidence in some canine breeds (Retrievers, Rottweiler, Newfoundland, Bernese mountain dog etc.) (Olsson 1975; Guthrie and Pidduck 1990). It can be revealed in various forms, (FCP,UAP,OCD,INC) and if it is not precociously diagnosed it also leads, sometimes inevitably, to forms of severe arthrosis (Olsson 1975; Hornof et al. 2000; Kunzel et al. 2004; Blond et al. 2005). The diagnostic procedure consists, besides the clinical examination, of a standardized radiographic examination according to the indications furnished by the International Elbow Working Group (IEWG), that however gives only information on the presence or lack of secondary osteoarthrosic damage (Van Bree and Van Ryssen 1995; Hornof et al. 2000; Blond et al. 2005). For this reason, in the last decade the use of second level imaging