XIPING CUI

XIPING CUI


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2022 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
HYHuiyi Yang
Huiyi Yang
QHQiyi He
Qiyi He
MLMingxia Lin
Mingxia Lin
LJLi Ji
Li Ji
LZLeheng Zhang
Leheng Zhang
SZsuqing Zhao
suqing Zhao

1 April 2019 in Talanta
Verified
Journal Article
Closed access
QHQiyi He
Qiyi He
YCYingshan Chen
Yingshan Chen
DSDING SHEN
DING SHEN
XCXIPING CUI
XIPING CUI
CZchunguo zhang
chunguo zhang
SZsuqing Zhao
suqing Zhao

1 August 2020 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
QHQiyi He
Qiyi He
HYHuiyi Yang
Huiyi Yang
YCYingshan Chen
Yingshan Chen
DSDING SHEN
DING SHEN
XCXIPING CUI
XIPING CUI
SZsuqing Zhao
suqing Zhao

6 October 2020 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
HYHuiyi Yang
Huiyi Yang
QHQiyi He
Qiyi He
YCYingshan Chen
Yingshan Chen
DSDING SHEN
DING SHEN
HXHuanxin Xiao
Huanxin Xiao
SZsuqing Zhao
suqing Zhao

12 November 2021 in The Analyst
Verified
Journal Article
Closed access
PDF file
JPJunkang Pan
Junkang Pan
QHQiyi He
Qiyi He
ZLZhiting Lao
Zhiting Lao
YZYikui Zou
Yikui Zou
JSJingyi Su
Jingyi Su
SZsuqing Zhao
suqing Zhao
As a neglected member of the platinum group elements, osmium, the metal with the highest density in the earth, is very suitable for the preparation of a peroxidase with high catalytic activity and stability, and can also be associated with the development of a sensor. In this study, we accessed Os nano-hydrangeas (OsNHs) with one-pot synthesis and utilized them in a bifunctional immunosensor that can present both catalytic chromogenic and tinctorial signal for nanozyme-linked immunosorbent assay (NLISA) and lateral flow immunoassay (LFIA) for use in folic acid (FA) detection. In the OsNHs-NLISA, the linear range is from 9.42 to 167.53 ng mL−1. The limit of detection (LOD) is 4.03 ng mL−1 and the IC50 value is 39.73 ng mL−1. In OsNHs-LFIA, the visual cut-off value and limit of detection (v-LOD) are 100 ng mL−1 and 0.01 ng mL−1, respectively. Additionally, the outcome from the specificity and spiked sample analysis offered recovery from the spiked milk powder sample ranging from 93.9 to 103.6% with a coefficient of variation under 4.9%, compared with UPLC-MS/MS for a correlation of R2 = 0.999 and admirable validation. The promising application of the OsNHs can also be used in other bioprobes, and this bifunctional immunosensor analysis mode is suitable for diversified analytes.

25 February 2021 in The Analyst
Verified
Journal Article
Closed access
PDF file
HYHuiyi Yang
Huiyi Yang
QHQiyi He
Qiyi He
JPJunkang Pan
Junkang Pan
DSDing Shen
Ding Shen
HXHuanxin Xiao
Huanxin Xiao
SZsuqing Zhao
suqing Zhao
The traditional gold-nanoparticle-based lateral flow immunoassay (LFIA) cannot satisfy the requirements for the sensitive detection of dehydroepiandrosterone (DHEA) in human urine. To enhance the sensitivity of the LFIA, platinum–iridium nanocubes (Pt–Ir NCs) with high catalytic efficiency and stability were synthesized and labelled with polyclonal antibody (pAb) to form a pAb–Pt–Ir probe. For the detection of DHEA, a novel LFIA with Pt–Ir NCs as an optical label and an enhanced LFIA in which the peroxidase-like activity of the Pt–Ir NCs was triggered by the introduction of the chromogenic substrate 3-amino-9-ethyl-carbazole (AEC) were developed and compared with a LFIA with platinum nanocubes (PtNCs) as an optical label. The visual limit of detection was 0.5 ng mL−1 for Pt–Ir-LFIA and 0.05 ng mL−1 for AEC-enhanced Pt–Ir-LFIA, in comparison to 100 ng mL−1 for PtNCs-LFIA and 50 ng mL−1 for AEC-enhanced PtNCs-LFIA. The average recoveries from spiked urine samples ranged from 90.8% to 110.4%, with a coefficient of variation below 12.6%, suggesting the accuracy and reliability of our developed immunoassay. Achieving excellent sensitivity, specificity, and reproducibility, Pt–Ir-LFIA provided a promising platform for monitoring DHEA.