As a neglected member of the platinum group elements, osmium, the metal with the highest density in the earth, is very suitable for the preparation of a peroxidase with high catalytic activity and stability, and can also be associated with the development of a sensor. In this study, we accessed Os nano-hydrangeas (OsNHs) with one-pot synthesis and utilized them in a bifunctional immunosensor that can present both catalytic chromogenic and tinctorial signal for nanozyme-linked immunosorbent assay (NLISA) and lateral flow immunoassay (LFIA) for use in folic acid (FA) detection. In the OsNHs-NLISA, the linear range is from 9.42 to 167.53 ng mL−1. The limit of detection (LOD) is 4.03 ng mL−1 and the IC50 value is 39.73 ng mL−1. In OsNHs-LFIA, the visual cut-off value and limit of detection (v-LOD) are 100 ng mL−1 and 0.01 ng mL−1, respectively. Additionally, the outcome from the specificity and spiked sample analysis offered recovery from the spiked milk powder sample ranging from 93.9 to 103.6% with a coefficient of variation under 4.9%, compared with UPLC-MS/MS for a correlation of R2 = 0.999 and admirable validation. The promising application of the OsNHs can also be used in other bioprobes, and this bifunctional immunosensor analysis mode is suitable for diversified analytes.
The traditional gold-nanoparticle-based lateral flow immunoassay (LFIA) cannot satisfy the requirements for the sensitive detection of dehydroepiandrosterone (DHEA) in human urine. To enhance the sensitivity of the LFIA, platinum–iridium nanocubes (Pt–Ir NCs) with high catalytic efficiency and stability were synthesized and labelled with polyclonal antibody (pAb) to form a pAb–Pt–Ir probe. For the detection of DHEA, a novel LFIA with Pt–Ir NCs as an optical label and an enhanced LFIA in which the peroxidase-like activity of the Pt–Ir NCs was triggered by the introduction of the chromogenic substrate 3-amino-9-ethyl-carbazole (AEC) were developed and compared with a LFIA with platinum nanocubes (PtNCs) as an optical label. The visual limit of detection was 0.5 ng mL−1 for Pt–Ir-LFIA and 0.05 ng mL−1 for AEC-enhanced Pt–Ir-LFIA, in comparison to 100 ng mL−1 for PtNCs-LFIA and 50 ng mL−1 for AEC-enhanced PtNCs-LFIA. The average recoveries from spiked urine samples ranged from 90.8% to 110.4%, with a coefficient of variation below 12.6%, suggesting the accuracy and reliability of our developed immunoassay. Achieving excellent sensitivity, specificity, and reproducibility, Pt–Ir-LFIA provided a promising platform for monitoring DHEA.