Gerhard Ulbricht

Dr. Gerhard Ulbricht

Dublin Institute for Advanced Studies
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2007 in Nature Physics
Verified
Journal Article
Closed access
JMJ. Martin
J. Martin
NAN. Akerman
N. Akerman
GUGerhard Ulbricht
Gerhard Ulbricht
TLT. Lohmann
T. Lohmann
JSJ. H. Smet
J. H. Smet
AYA. Yacoby
A. Yacoby

1 November 2013 in Publications of the Astronomical Society of the Pacific
Verified
Journal Article
Closed access
PDF file
BMB. A. Mazin
B. A. Mazin
SMS. R. Meeker
S. R. Meeker
MSM. J. Strader
M. J. Strader
PSPaul Szypryt
Paul Szypryt
DMD. Marsden
D. Marsden
CSC. Stoughton
C. Stoughton
We present the design, construction, and commissioning results of ARCONS, the Array Camera for Optical to Near-IR Spectrophotometry. ARCONS is the first ground-based instrument in the optical through near-IR wavelength range based on Microwave Kinetic Inductance Detectors (MKIDs). MKIDs are revolutionary cryogenic detectors, capable of detecting single photons and measuring their energy without filters or gratings, similar to an X-ray microcalorimeter. MKIDs are nearly ideal, noiseless photon detectors, as they do not suffer from read noise or dark current and have nearly perfect cosmic ray rejection. ARCONS is an Integral Field Spectrograph (IFS) containing a lens-coupled 2024 pixel MKID array yielding a 20"x20" field of view, and has been deployed on the Palomar 200" and Lick 120" telescopes for 24 nights of observing. We present initial results showing that ARCONS and its MKID arrays are now a fully operational and powerful tool for astronomical observations.Comment: 12 pages, 16 figures, submitted to PAS

16 April 2018 in Publications of the Astronomical Society of the Pacific
Verified
Journal Article
Closed access
SMSeth R. Meeker
Seth R. Meeker
BMBenjamin A. Mazin
Benjamin A. Mazin
AWAlex B. Walter
Alex B. Walter
PSPaschal Strader
Paschal Strader
NFNeelay Fruitwala
Neelay Fruitwala
ESEugene Serabyn
Eugene Serabyn

10 October 2017 in Optics Express
Verified
Journal Article
Closed access
PDF file
PSPaul Szypryt
Paul Szypryt
SMS. R. Meeker
S. R. Meeker
GCG. Coiffard
G. Coiffard
NFN. Fruitwala
N. Fruitwala
BBB. Bumble
B. Bumble
BMB. A. Mazin
B. A. Mazin
We have fabricated and characterized 10,000 and 20,440 pixel Microwave Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive optics systems with the goal of directly imaging exoplanets in a 800–1400 nm band. Previous large optical and near-IR MKID arrays were fabricated using substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays, however, suffered from severe non-uniformities in the TiN critical temperature, causing resonances to shift away from their designed values and lowering usable detector yield. We have begun fabricating DARKNESS and MEC arrays using platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays have much higher uniformity than the TiN arrays, resulting in higher pixel yields, they have demonstrated better spectral resolution than TiN MKIDs of similar design. PtSi MKIDs also do not display the hot pixel effects seen when illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1 µm.

26 July 2009 in Nature Physics
Verified
Journal Article
Open access
JMJ. Martin
J. Martin
NAN. Akerman
N. Akerman
GUGerhard Ulbricht
Gerhard Ulbricht
TLT. Lohmann
T. Lohmann
KKK. von Klitzing
K. von Klitzing
AYA. Yacoby
A. Yacoby
Particle localization is an essential ingredient in quantum Hall physics [1,2]. In conventional high mobility two-dimensional electron systems Coulomb interactions were shown to compete with disorder and to play a central role in particle localization [3]. Here we address the nature of localization in graphene where the carrier mobility, quantifying the disorder, is two to four orders of magnitude smaller [4,5,6,7,8,9,10]. We image the electronic density of states and the localized state spectrum of a graphene flake in the quantum Hall regime with a scanning single electron transistor [11]. Our microscopic approach provides direct insight into the nature of localization. Surprisingly, despite strong disorder, our findings indicate that localization in graphene is not dominated by single particle physics, but rather by a competition between the underlying disorder potential and the repulsive Coulomb interaction responsible for screening.Comment: 18 pages, including 5 figure

17 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GUGerhard Ulbricht
Gerhard Ulbricht
MLMario De Lucia
Mario De Lucia
EBEoin Baldwin
Eoin Baldwin
In recent years Microwave Kinetic Inductance Detectors (MKIDs) have emerged as one of the most promising novel low temperature detector technologies. Their unrivaled scalability makes them very attractive for many modern applications and scientific instruments. In this paper we intend to give an overview of how and where MKIDs are currently being used or are suggested to be used in the future. MKID based projects are ongoing or proposed for observational astronomy, particle physics, material science and THz imaging, and the goal of this review is to provide an easily usable and thorough list of possible starting points for more in-depth literature research on the many areas profiting from kinetic inductance detectors.