Mario De Lucia

Mr. Mario De Lucia

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GUGerhard Ulbricht
Gerhard Ulbricht
MLMario De Lucia
Mario De Lucia
EBEoin Baldwin
Eoin Baldwin
In recent years Microwave Kinetic Inductance Detectors (MKIDs) have emerged as one of the most promising novel low temperature detector technologies. Their unrivaled scalability makes them very attractive for many modern applications and scientific instruments. In this paper we intend to give an overview of how and where MKIDs are currently being used or are suggested to be used in the future. MKID based projects are ongoing or proposed for observational astronomy, particle physics, material science and THz imaging, and the goal of this review is to provide an easily usable and thorough list of possible starting points for more in-depth literature research on the many areas profiting from kinetic inductance detectors.

1 July 2024 in Journal of Cosmology and Astroparticle Physics
Verified
Journal Article
Open access
SAS. Abe
S. Abe
JAJ. Abhir
J. Abhir
AAA. Abhishek
A. Abhishek
FAF. Acero
F. Acero
Atreya AcharyyaAtreya Acharyya
Atreya Acharyya
TCThe CTAO Consortium
The CTAO Consortium
Monochromatic gamma-ray signals constitute a potential smoking gun signature for annihilating or decaying dark matter particles that could relatively easily be distinguished from astrophysical or instrumental backgrounds. We provide an updated assessment of the sensitivity of the Cherenkov Telescope Array (CTA) to such signals, based on observations of the Galactic centre region as well as of selected dwarf spheroidal galaxies. We find that current limits and detection prospects for dark matter masses above 300 GeV will be significantly improved, by up to an order of magnitude in the multi-TeV range. This demonstrates that CTA will set a new standard for gamma-ray astronomy also in this respect, as the world's largest and most sensitive high-energy gamma-ray observatory, in particular due to its exquisite energy resolution at TeV energies and the adopted observational strategy focussing on regions with large dark matter densities. Throughout our analysis, we use up-to-date instrument response functions, and we thoroughly model the effect of instrumental systematic uncertainties in our statistical treatment. We further present results for other potential signatures with sharp spectral features, e.g. box-shaped spectra, that would likewise very clearly point to a particle dark matter origin.

31 October 2024 in Instruments
Verified
Journal Article
Open access
PDF file
MLMario De Lucia
Mario De Lucia
PBPaolo Dal Bo
Paolo Dal Bo
EGEugenia Di Giorgi
Eugenia Di Giorgi
TLTommaso Lari
Tommaso Lari
Claudio PugliaClaudio Puglia
Claudio Puglia
Federico PaolucciFederico Paolucci
Federico Paolucci
Transition Edge Sensors (TESs) are amongst the most sensitive cryogenic detectors and can be easily optimized for the detection of massive particles or photons ranging from X-rays all the way down to millimetre radiation. Furthermore, TESs exhibit unmatched energy resolution while being easily frequency domain multiplexed in arrays of several hundred pixels. Such great performance, along with rather simple and sturdy readout and amplification chains make TESs extremely compelling for applications in many fields of scientific endeavour. While the first part of this article is an in-depth discussion on the working principles of Transition Edge Sensors, the remainder of this review article focuses on the applications of Transition Edge Sensors in advanced scientific instrumentation serving as an accessible and thorough list of possible starting points for more comprehensive literature research.

1 December 2023 in AIP Advances
Verified
Journal Article
Open access
PDF file
MLMario De Lucia
Mario De Lucia
GUGerhard Ulbricht
Gerhard Ulbricht
EBE. Baldwin
E. Baldwin
JPJ. D. Piercy
J. D. Piercy
OCOisin Creaner
Oisin Creaner
TRT. P. Ray
T. P. Ray
This paper describes the energy resolution of microwave kinetic inductance detectors and models some limiting factors to it. Energy resolution is a measure of the smallest possible difference in energy of the impinging photons, ΔE, that the detector can identify and, as such, is of critical importance for many applications. Limits to the energy resolution caused by the Fano effect, amplifier noise, current inhomogeneities, and readout sampling frequency are taken into consideration for this model. This paper describes an approach to combine all of these limitations and predict a wavelength dependency of the upper limit to the resolving power.

23 March 2026 in The European Physical Journal C
Verified
Journal Article
Open access
MFM. Folcarelli
M. Folcarelli
DDD. Delicato
D. Delicato
AAA. Acevedo-Rentería
A. Acevedo-Rentería
LAL. E. Ardila-Perez
L. E. Ardila-Perez
LBLaura Bandiera
Laura Bandiera
KZKangkang Zhao
Kangkang Zhao
BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates, with mass $$\lesssim 1$$ ≲ 1 GeV/c $$^2$$ 2 , and coherent neutrino-nucleus scattering. It is based on an array of dice carved in 5 mm thick silicon crystal, sensed by phonon-mediated Kinetic Inductance Detectors. In previous works, the array was calibrated with bursts of optical photons, which are absorbed in the first hundreds nanometers of the dice and give rise to surface events. In this work, we present the reconstruction of bulk events through the 59.5 keV $$\gamma $$ γ -ray generated by an $$^{241}$$ 241 Am source, which emulates more closely the interaction of Dark Matter and neutrinos. The peak resolution is $$5\%~(\sigma )$$ 5 % ( σ ) and its position is shifted by less than $$10\%$$ 10 % with respect to the optical calibration. We observe that the resolution is further improved by a factor 2 combining the signal from neighboring dice. These results confirm the performance of the detector in view of the physics goals of the BULLKID-DM experiment for dark matter search.

13 December 2020
Verified
Conference Paper
Open access
MLMario De Lucia
Mario De Lucia
EBEoin Baldwin
Eoin Baldwin
GUGerhard Ulbricht
Gerhard Ulbricht
CBColm Bracken
Colm Bracken
PSPlamen Stamenov
Plamen Stamenov
TRTom P. Ray
Tom P. Ray
SPIE Digital Library Proceedings