Rongxin Yin

Mr. Rongxin Yin

Lawrence Berkeley National Laboratory, Berkeley, USA
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2023 in Building and Environment
Verified
Journal Article
Closed access
RYRongxin Yin
Rongxin Yin
JLJingjing Liu
Jingjing Liu
MPMary Ann Piette
Mary Ann Piette
JXJiarong Xie
Jiarong Xie
Marco PritoniMarco Pritoni
Marco Pritoni
PSPeter Schwartz
Peter Schwartz

19 June 2021 in Energies
Verified
Journal Article
Open access
PDF file
HAHyeunguk Ahn
Hyeunguk Ahn
JLJingjing Liu
Jingjing Liu
DKDonghun Kim
Donghun Kim
RYRongxin Yin
Rongxin Yin
THTianzhen Hong
Tianzhen Hong
MPMary Ann Piette
Mary Ann Piette
Although the thermal mass of floors in buildings has been demonstrated to help shift cooling load, there is still a lack of information about how floor covering can influence the floor’s load shifting capability and buildings’ demand flexibility. To fill this gap, we estimated demand flexibility based on the daily peak cooling load reduction for different floor configurations and regions, using EnergyPlus simulations. As a demand response strategy, we used precooling and global temperature adjustment. The result demonstrated an adverse impact of floor covering on the building’s demand flexibility. Specifically, under the same demand response strategy, the daily peak cooling load reductions were up to 20–34% for a concrete floor whereas they were only 17–29% for a carpet-covered concrete floor. This is because floor covering hinders convective coupling between the concrete floor surface and the zone air and reduces radiative heat transfer between the concrete floor surface and the surrounding environment. In hot climates such as Phoenix, floor covering almost negated the concrete floor’s load shifting capability and yielded low demand flexibility as a wood floor, representing low thermal mass. Sensitivity analyses showed that floor covering’s effects can be more profound with a larger carpet-covered area, a greater temperature adjustment depth, or a higher radiant heat gain. With this effect ignored for a given building, its demand flexibility would be overestimated, which could prevent grid operators from obtaining sufficient demand flexibility to maintain a grid. Our findings also imply that for more efficient grid-interactive buildings, a traditional standard for floor design could be modified with increasing renewable penetration.

1 November 2008
Verified
Report
Closed access
PDF file
RYRongxin Yin
Rongxin Yin
PXPeng Xu
Peng Xu
SKSila Kiliccote
Sila Kiliccote
Over the several past years, Lawrence Berkeley National Laboratory (LBNL) has conducted field tests for different pre-cooling strategies in different commercial buildings within California. The test results indicated that pre-cooling strategies were effective in reducing electric demand in these buildings during peak periods. This project studied how to optimize pre-cooling strategies for eleven buildings in the Tri-City Corporate Center, San Bernardino, California with the assistance of a building energy simulation tool -- the Demand Response Quick Assessment Tool (DRQAT) developed by LBNL's Demand Response Research Center funded by the California Energy Commission's Public Interest Energy Research (PIER) Program. From the simulation results of these eleven buildings, optimal pre-cooling and temperature reset strategies were developed. The study shows that after refining and calibrating initial models with measured data, the accuracy of the models can be greatly improved and the models can be used to predict load reductions for automated demand response (Auto-DR) events. This study summarizes the optimization experience of the procedure to develop and calibrate building models in DRQAT. In order to confirm the actual effect of demand response strategies, the simulation results were compared to the field test data. The results indicated that the optimal demand response strategies workedmore » well for all buildings in the Tri-City Corporate Center. This study also compares DRQAT with other building energy simulation tools (eQUEST and BEST). The comparison indicate that eQUEST and BEST underestimate the actual demand shed of the pre-cooling strategies due to a flaw in DOE2's simulation engine for treating wall thermal mass. DRQAT is a more accurate tool in predicting thermal mass effects of DR events.« less

27 March 2025 in Buildings
Verified
Journal Article
Open access
PDF file
LZLining Zhou
Lining Zhou
QWQingqin Wang
Qingqin Wang
HZHaizhu Zhou
Haizhu Zhou
YJYiqiang Jiang
Yiqiang Jiang
RYRongxin Yin
Rongxin Yin
TLTong Lu
Tong Lu
Urban carbon emissions account for 75% of the total social emissions and are a key area for achieving the country’s “dual carbon” goals. This study takes the Sino-Singapore Tianjin Eco-City as a case, constructs a multi-dimensional carbon emission accounting model, integrates six systems, including buildings, transportation, water systems, solid waste, renewable energy, and carbon sinks, and proposes a comprehensive research method that takes into account both long-term prediction and a short-term dynamic analysis. The long-term emission trends under different scenarios are simulated through the KAYA model. It is found that under the enhanced low-carbon scenario, the Eco-City will reach its peak in 2043 (2.253 million tons of CO2) and drop to 2.182 million tons of CO2 in 2050. At the same time, after comparing models, such as random forest and support vector machine, the XGBoost algorithm is adopted for short-term prediction (R2 = 0.984, MAE = 0.195). The results show that it is significantly superior to traditional methods and can effectively capture the dynamic changes in fields, such as buildings and transportation. Based on the prediction results, the study proposes six types of collaborative emission-reduction paths: improving building energy efficiency (annual emission reduction of 93800 tons), promoting green travel (58,900 tons), increasing the utilization rate of non-conventional water resources (3700 tons), reducing per capita solid waste generation (14,400 tons), expanding the application of renewable energy (288,200 tons), and increasing green space carbon sinks (135,000 tons). The total annual emission-reduction potential amounts to 594,000 tons. This study provides a valuable reference for developing carbon reduction strategies in urban areas.

26 April 2025 in SoftwareX
Verified
Journal Article
Open access
MLMichael Leong
Michael Leong
MMMedha Mahanta
Medha Mahanta
CYClara Yin
Clara Yin
TGTimothy Jairus Garcia
Timothy Jairus Garcia
ZTZach Tan
Zach Tan
RYRongxin Yin
Rongxin Yin

12 May 2022 in arXiv
Verified
Preprint
Open access
PDF file
YCYujiao Chen
Yujiao Chen
RYRongxin Yin
Rongxin Yin
The smart control informed by IoT sensors and enabled by remotely controlled devices can optimize the building operation to minimize unnecessary energy consumption and improve indoor thermal comfort. This paper quantifies the potential for electricity savings in small office buildings from smart thermostat control and occupancy-informed smart plug control. This is done by simulating the effect of adaptive setpoint temperature, occupancy-based HVAC control, and night-purge free cooling on small office buildings across all major climate zones in the United States. Adopting these smart control measures can achieve 8.9% to 20.4% of savings in total electricity consumption of small office buildings, or equivalent to annual reductions between 12.2 kWh/m2 and 30.4 kWh/m2 in electricity usage intensity. Among all climate zones, the hot and dry climates benefit the most from proposed smart controls and achieve the highest percentages of electricity savings