Hyeunguk Ahn

Hyeunguk Ahn

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Energy Policy
Verified
Journal Article
Open access
HAHyeunguk Ahn
Hyeunguk Ahn
WMWilliam Miller
William Miller
PSPaul Sheaffer
Paul Sheaffer
VTVestal Tutterow
Vestal Tutterow
VRVi Rapp
Vi Rapp

21 August 2023 in Journal of Building Engineering
Verified
Journal Article
Closed access
GLGyueun Lee
Gyueun Lee
NANadia Avelina
Nadia Avelina
DRDonghyun Rim
Donghyun Rim
SCSeokho Chi
Seokho Chi
HAHyeunguk Ahn
Hyeunguk Ahn

25 August 2024 in Energy and Buildings
Verified
Journal Article
Closed access
HKHye Gi Kim
Hye Gi Kim
SKSun Sook Kim
Sun Sook Kim
HAHyeunguk Ahn
Hyeunguk Ahn


18 February 2025 in Energy
Verified
Journal Article
Closed access
HLHyeonjun Lee
Hyeonjun Lee
DRDonghyun Rim
Donghyun Rim
HAHyeunguk Ahn
Hyeunguk Ahn

19 June 2021 in Energies
Verified
Journal Article
Open access
PDF file
HAHyeunguk Ahn
Hyeunguk Ahn
JLJingjing Liu
Jingjing Liu
DKDonghun Kim
Donghun Kim
RYRongxin Yin
Rongxin Yin
THTianzhen Hong
Tianzhen Hong
MPMary Ann Piette
Mary Ann Piette
Although the thermal mass of floors in buildings has been demonstrated to help shift cooling load, there is still a lack of information about how floor covering can influence the floor’s load shifting capability and buildings’ demand flexibility. To fill this gap, we estimated demand flexibility based on the daily peak cooling load reduction for different floor configurations and regions, using EnergyPlus simulations. As a demand response strategy, we used precooling and global temperature adjustment. The result demonstrated an adverse impact of floor covering on the building’s demand flexibility. Specifically, under the same demand response strategy, the daily peak cooling load reductions were up to 20–34% for a concrete floor whereas they were only 17–29% for a carpet-covered concrete floor. This is because floor covering hinders convective coupling between the concrete floor surface and the zone air and reduces radiative heat transfer between the concrete floor surface and the surrounding environment. In hot climates such as Phoenix, floor covering almost negated the concrete floor’s load shifting capability and yielded low demand flexibility as a wood floor, representing low thermal mass. Sensitivity analyses showed that floor covering’s effects can be more profound with a larger carpet-covered area, a greater temperature adjustment depth, or a higher radiant heat gain. With this effect ignored for a given building, its demand flexibility would be overestimated, which could prevent grid operators from obtaining sufficient demand flexibility to maintain a grid. Our findings also imply that for more efficient grid-interactive buildings, a traditional standard for floor design could be modified with increasing renewable penetration.