Michelangelo Pari

Mr. Michelangelo Pari

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Journal of Instrumentation
Verified
Journal Article
Open access
PDF file
GBG. Ballerini
G. Ballerini
ABA. Berra
A. Berra
RBR. Boanta
R. Boanta
CBC. Brizzolari
C. Brizzolari
GBGiulia Brunetti
Giulia Brunetti
EVE. Vallazza
E. Vallazza
An iron- plastic-scintillator shashlik calorimeter with a 4.3 X0 longitudinal segmentation was tested in November 2016 at the CERN East Area facility with charged particles up to 5 GeV . The performance of this detector in terms of electron energy resolution, linearity, response to muons and hadron showers are presented in this paper and compared with simulation. Such a fine-grained longitudinal segmentation is achieved using a very compact light readout system developed by the SCENTT and ENUBET Collaborations, which is based on fiber-SiPM coupling boards embedded in the bulk of the detector. We demonstrate that this system fulfills the requirements for neutrino physics applications and discuss performance and additional improvements.

23 February 2026 in The European Physical Journal C
Verified
Journal Article
Open access
PDF file
KAK. Abe
K. Abe
MAM. T. Afif
M. T. Afif
RLR. Ahl Laamara
R. Ahl Laamara
HAH. Aihara
H. Aihara
AAA. Ajmi
A. Ajmi
SZS. Zsoldos
S. Zsoldos
This paper presents the expected sensitivity to the neutrino oscillation parameters of the Hyper-Kamiokande long-baseline program. The Hyper-Kamiokande experiment, currently under construction in Japan, will measure the oscillations of accelerator-produced neutrinos with thousands of selected events per sample: this corresponds to an increase of statistics of a factor 25–100 with respect to recent results from the currently-running long-baseline neutrino oscillation experiment in Japan, T2K. In the most favorable scenario we will achieve the discovery of Charge-Parity (CP) violation in neutrino oscillation at $$5\sigma $$ 5 σ C.L. in less than 3 years. With 10 years of data-taking, and assuming a neutrino : antineutrino beam running ratio of 1:3, a CP violation discovery at $$5\sigma $$ 5 σ C.L. is possible for more than 60% of the actual values of the CP-violating phase, $$\delta _{CP}.$$ δ CP . Moreover, we will measure $$\delta _{CP}$$ δ CP with a precision ranging from 20 $$^{\circ },$$ ∘ , in the case of maximal CP violation, to 6 $$^{\circ },$$ ∘ , in the case of CP conservation. We aim to achieve a 0.5% resolution on the $$\Delta m^2_{32}$$ Δ m 32 2 parameter, and a resolution between 3% and 0.5% on the $$\sin ^2\theta _{23}$$ sin 2 θ 23 parameter, depending on its true value. These results are obtained by extending the analysis methods of T2K with dedicated tuning to take into account the Hyper-Kamiokande design: the larger far detector, the more powerful beam, the upgraded near detector ND280, and the planned additional Intermediate Water Cherenkov Detector.

6 August 2023 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
LAL. Ambrosi
L. Ambrosi
DADavid Attié
David Attié
OBOtger Ballester
Otger Ballester
MBM. Batkiewicz-Kwasniak
M. Batkiewicz-Kwasniak
PBP. Billoir
P. Billoir
MZM. Zito
M. Zito

11 December 2019 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
MFMatthew Alexander Fraser
Matthew Alexander Fraser
BGBrennan Goddard
Brennan Goddard
VKVerena Kain
Verena Kain
MPMichelangelo Pari
Michelangelo Pari
FVFrancesco Maria Velotti
Francesco Maria Velotti
MBMichael Benedikt
Michael Benedikt
The powering of octupoles during third-integer resonant slow extraction has been studied and recently tested with the beam at the CERN Super Proton Synchrotron (SPS) in order to increase the extraction efficiency and reduce the induced radioactivity along the extraction straight. The octupoles distort the particle trajectories in phase space in such a way that the extracted separatrix is folded, which decreases the particle density impinging the wires of the extraction septum at the expense of increasing the extracted beam emittance. During experimental SPS machine studies a reduction of over 40% in the specific (per extracted proton) beam loss measured at the extraction septum was achieved. In this paper, the prerequisite studies needed to safely deploy the new extraction scheme in a limited time-frame are described, the experimental results are presented and an outlook given toward the next steps to bring slow extraction with octupoles into routine operation.

11 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NCNikolaos Charitonidis
Nikolaos Charitonidis
ALAndrea Longhin
Andrea Longhin
MPMichelangelo Pari
Michelangelo Pari
EPElisabetta Giulia Parozzi
Elisabetta Giulia Parozzi
Francesco TerranovaFrancesco Terranova
Francesco Terranova
Neutrino oscillation physics has entered a new precision era, which poses major challenges to the level of control and diagnostics of the neutrino beams. In this paper, we review the design of high-precision beams, their current limitations, and the latest techniques envisaged to overcome such limits. We put emphasis on “monitored neutrino beams” and advanced diagnostics to determine the flux and flavor of the neutrinos produced at the source at the per-cent level. We also discuss ab-initio measurements of the neutrino energy–i.e., measurements performed without relying on the event reconstruction at the ν detector–to remove any flux induced bias in the determination of the cross sections.

22 April 2026 in Physical Review Letters
Verified
Journal Article
Open access
AHA. Hayrapetyan
A. Hayrapetyan
VMV. Makarenko
V. Makarenko
ATA. Tumasyan
A. Tumasyan
WAW. Adam
W. Adam
LBL. Benato
L. Benato
ASA. Snigirev
A. Snigirev
A hot and dense state of nuclear matter, known as the quark-gluon plasma, is created in collisions of ultrarelativistic heavy nuclei. Highly energetic quarks and gluons, collectively referred to as partons, lose energy as they travel through this matter, leading to suppressed production of particles with large transverse momenta ( p T ). Conversely, high- p T particle suppression has not been seen in proton-lead collisions, raising questions regarding the minimum system size required to observe parton energy loss. Oxygen-oxygen (OO) collisions examine a region of effective system size that lies between these two extreme cases. The CMS detector at the CERN LHC has been used to quantify charged-particle production in inclusive OO collisions for the first time via measurements of the nuclear modification factor ( R AA ). The R AA is derived by comparing particle production to expectations based on proton-proton ( p p ) data and has a value of unity in the absence of nuclear effects. The data for OO and p p collisions at a nucleon-nucleon center-of-mass energy s NN = 5.36 TeV correspond to integrated luminosities of 6.1 nb − 1 and 1.02 pb − 1 , respectively. The R AA is below unity with a minimum of 0.69 ± 0.04 around p T = 6 GeV . The data exhibit better agreement with theoretical models incorporating parton energy loss as compared to baseline models without energy loss.