kaiqi Sun

Dr. kaiqi Sun


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2018 in Energies
Verified
Journal Article
Open access
PDF file
ZLZhijie Liu
Zhijie Liu
KLKe-Jun Li
Ke-Jun Li
YSYuanyuan Sun
Yuanyuan Sun
JWJinyu Wang
Jinyu Wang
ZWZhuo-di Wang
Zhuo-di Wang
MWMeiyan Wang
Meiyan Wang
Modular multilevel converters (MMCs) have shown great potential in the area of multi-megawatt wind energy conversion system (WECS) based on permanent magnet synchronous generators (PMSGs). However, the studies in this area are few, and most of them refer to the MMC used in high-voltage direct current (HVDC) systems, and hence the characteristics of the PMSG are not considered. This paper proposes a steady-state analysis method for MMCs connected to a PMSG-based WECS. In the proposed method, only the wind speed (operating condition) is required as input, and all the electrical quantities in the MMC, including the amplitudes, phase angles and their harmonics, can be calculated step by step. The analysis method is built on the proposed d-q frame mathematical model. Interactions of electrical quantities between the MMC and PMSG are comprehensively considered. Moreover, a new way to calculate the average switching functions are adopted in order to improve the accuracy of the analysis method. Applications of the proposed method are also presented, which includes the characteristic analysis of capacitor voltage ripples and the capacitor sizing. Finally, the accuracy of the method and the correctness of the analysis are verified by simulations and experiments.

14 February 2020 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
Huangqing XiaoHuangqing Xiao
Huangqing Xiao
KSkaiqi Sun
kaiqi Sun
JPJiuping Pan
Jiuping Pan
YLYilu Liu
Yilu Liu
In this study, a new kind of hybrid high‐voltage direct current (HVDC) system is proposed. Each terminal of the proposed system consists of one line commutated converter (LCC) and one full‐bridge modular multilevel converter (FB‐MMC). The LCC and FB‐MMC are connected in parallel so that they can share the same transmission line. The active–reactive power capability of the hybrid HVDC system is extended compared with the conventional LCC‐HVDC system, and power reversal control without power interruption can be achieved by the coordination control of LCC and FB‐MMC. Besides, the proposed hybrid HVDC system is capable of handling DC fault, because both LCC and FB‐MMC have DC fault blocking capability. Moreover, the power rating of FB‐MMC can be designed to low value while keeping the bulk‐power transmission capability of LCC. A two‐terminal bipolar hybrid HVDC system is built in PSCAD/EMTDC. The simulation results verify the effectiveness and feasibility of the proposed hybrid topology and corresponding control strategies.

8 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZWZhuo-di Wang
Zhuo-di Wang
KLKe-Jun Li
Ke-Jun Li
JLJun Liang
Jun Liang
KSkaiqi Sun
kaiqi Sun
JWJinyu Wang
Jinyu Wang
ZLZhijie Liu
Zhijie Liu
The coastal urban multi-terminal DC (CU-MTDC) is a prospective solution for enhancing the power supply security of the coastal urban power (CUP) grid and integrating the large-scale offshore wind farm. However, the large DC disturbances may significantly impact the CUP power supply security. The existing DC unbalanced power distribution methods are difficult to be applied in the CU-MTDC because of the complicated optimization process and the expansion of the influence range of a DC fault. To solve the above problems, this paper proposes a coordinated control strategy of CU-MTDC under abnormal conditions. First, calculation principles for the active power reference of center coastal urban power (CCUP) grid converters are proposed. Second, a DC unbalanced power coordinated distribution strategy under abnormal conditions is used based on the dynamic priority control to ensure power supply security of the critical AC lines. Third, the controller parameters of CCUP grid converters are calculated. Through a simple control process, the number of the regulation converters is dynamically scheduled according to the DC unbalanced power. The DC fault influence range on the urban power grid can be limited in a sufficiently small area. Simulation verified the effectiveness of the proposed control strategy.