Marco Penso

Dr. Marco Penso

Centro Cardiologico Monzino, IRCC, Milan, Italy
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
MPMarco Penso
Marco Penso
Sara MocciaSara Moccia
Sara Moccia
SSStefano Scafuri
Stefano Scafuri
GMGiuseppe Muscogiuri
Giuseppe Muscogiuri
Gianluca PontoneGianluca Pontone
Gianluca Pontone
Enrico Gianluca CaianiEnrico Gianluca Caiani
Enrico Gianluca Caiani

Verified
Journal Article
Open access
PDF file
MPMarco Penso
Marco Penso
Mauro PepiMauro Pepi
Mauro Pepi
Laura FusiniLaura Fusini
Laura Fusini
MMManuela Muratori
Manuela Muratori
CCClaudia Cefalù
Claudia Cefalù
GTGloria Tamborini
Gloria Tamborini
Background: Whereas transcatheter aortic valve implantation (TAVI) has become the gold standard for aortic valve stenosis treatment in high-risk patients, it has recently been extended to include intermediate risk patients. However, the mortality rate at 5 years is still elevated. The aim of the present study was to develop a novel machine learning (ML) approach able to identify the best predictors of 5-year mortality after TAVI among several clinical and echocardiographic variables, which may improve the long-term prognosis. Methods: We retrospectively enrolled 471 patients undergoing TAVI. More than 80 pre-TAVI variables were collected and analyzed through different feature selection processes, which allowed for the identification of several variables with the highest predictive value of mortality. Different ML models were compared. Results: Multilayer perceptron resulted in the best performance in predicting mortality at 5 years after TAVI, with an area under the curve, positive predictive value, and sensitivity of 0.79, 0.73, and 0.71, respectively. Conclusions: We presented an ML approach for the assessment of risk factors for long-term mortality after TAVI to improve clinical prognosis. Fourteen potential predictors were identified with the organic mitral regurgitation (myxomatous or calcific degeneration of the leaflets and/or annulus) which showed the highest impact on 5 years mortality.

3 May 2023 in Journal of Cardiovascular Computed Tomography
Verified
Journal Article
Closed access
Andrea BaggianoAndrea Baggiano
Andrea Baggiano
Edoardo ConteEdoardo Conte
Edoardo Conte
LSLuigi Spiritigliozzi
Luigi Spiritigliozzi
SMSaima Mushtaq
Saima Mushtaq
AAAndrea Daniele Annoni
Andrea Daniele Annoni
Gianluca PontoneGianluca Pontone
Gianluca Pontone

27 December 2022 in Computers in Biology and Medicine
Verified
Journal Article
Open access
MPMarco Penso
Marco Penso
Sara MocciaSara Moccia
Sara Moccia
Enrico Gianluca CaianiEnrico Gianluca Caiani
Enrico Gianluca Caiani
GCGloria Caredda
Gloria Caredda
MLMaria Luisa Lampus
Maria Luisa Lampus
Gianluca PontoneGianluca Pontone
Gianluca Pontone
In patients with suspected Coronary Artery Disease (CAD), the severity of stenosis needs to be assessed for precise clinical management. An automatic deep learning-based algorithm to classify coronary stenosis lesions according to the Coronary Artery Disease Reporting and Data System (CAD-RADS) in multiplanar reconstruction images acquired with Coronary Computed Tomography Angiography (CCTA) is proposed. In this retrospective study, 288 patients with suspected CAD who underwent CCTA scans were included. To model long-range semantic information, which is needed to identify and classify stenosis with challenging appearance, we adopted a token-mixer architecture (ConvMixer), which can learn structural relationship over the whole coronary artery. ConvMixer consists of a patch embedding layer followed by repeated convolutional blocks to enable the algorithm to learn long-range dependences between pixels. To visually assess ConvMixer performance, Gradient-Weighted Class Activation Mapping (Grad-CAM) analysis was used. Experimental results using 5-fold cross-validation showed that our ConvMixer can classify significant coronary artery stenosis (i.e., stenosis with luminal narrowing ≥50%) with accuracy and sensitivity of 87% and 90%, respectively. For CAD-RADS 0 vs. 1-2 vs. 3-4 vs. 5 classification, ConvMixer achieved accuracy and sensitivity of 72% and 75%, respectively. Additional experiments showed that ConvMixer achieved a better trade-off between performance and complexity compared to pyramid-shaped convolutional neural networks. Our algorithm might provide clinicians with decision support, potentially reducing the interobserver variability for coronary artery stenosis evaluation.

21 January 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GIGianpiero Italiano
Gianpiero Italiano
Laura FusiniLaura Fusini
Laura Fusini
VMValentina Mantegazza
Valentina Mantegazza
GTGloria Tamborini
Gloria Tamborini
MMManuela Muratori
Manuela Muratori
Mauro PepiMauro Pepi
Mauro Pepi
Cardiovascular imaging is developing at a rapid pace and the newer modalities, in particular three-dimensional echocardiography, allow better analysis of heart structures. Identifying valve lesions and grading their severity represents crucial information and nowadays is strengthened by the introduction of new software, such as transillumination, which provide detailed morphology descriptions. Chambers quantification has never been so rapid and accurate: machine learning algorithms generate automated volume measurements, including left ventricular systolic and diastolic function, which is extremely important for clinical decisions. This review provides an overview of the latest innovations in the echocardiography field, and is helpful by providing a better insight into heart diseases.

25 August 2021 in Bioengineering
Verified
Journal Article
Open access
PDF file
MPMarco Penso
Marco Penso
Mauro PepiMauro Pepi
Mauro Pepi
VMValentina Mantegazza
Valentina Mantegazza
CCClaudia Cefalù
Claudia Cefalù
MMManuela Muratori
Manuela Muratori
GTGloria Tamborini
Gloria Tamborini
Background: Mitral valve regurgitation (MR) is the most common valvular heart disease and current variables associated with MR recurrence are still controversial. We aim to develop a machine learning-based prognostic model to predict causes of mitral valve (MV) repair failure and MR recurrence. Methods: 1000 patients who underwent MV repair at our institution between 2008 and 2018 were enrolled. Patients were followed longitudinally for up to three years. Clinical and echocardiographic data were included in the analysis. Endpoints were MV repair surgical failure with consequent MV replacement or moderate/severe MR (>2+) recurrence at one-month and moderate/severe MR recurrence after three years. Results: 817 patients (DS1) had an echocardiographic examination at one-month while 295 (DS2) also had one at three years. Data were randomly divided into training (DS1: n = 654; DS2: n = 206) and validation (DS1: n = 164; DS2 n = 89) cohorts. For intra-operative or early MV repair failure assessment, the best area under the curve (AUC) was 0.75 and the complexity of mitral valve prolapse was the main predictor. In predicting moderate/severe recurrent MR at three years, the best AUC was 0.92 and residual MR at six months was the most important predictor. Conclusions: Machine learning algorithms may improve prognosis after MV repair procedure, thus improving indications for correct candidate selection for MV surgical repair.