Enrico Gianluca Caiani

Prof. Enrico Gianluca Caiani

Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria
+1
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2004 in Circulation
Verified
Journal Article
Closed access
PDF file
VMVictor Mor-Avi
Victor Mor-Avi
LSLissa Sugeng
Lissa Sugeng
LWLynn Weinert
Lynn Weinert
PMPeter MacEneaney
Peter MacEneaney
Enrico Gianluca CaianiEnrico Gianluca Caiani
Enrico Gianluca Caiani
RLRoberto M. Lang
Roberto M. Lang
Background— Left ventricular (LV) mass is an important predictor of morbidity and mortality, especially in patients with systemic hypertension. However, the accuracy of 2D echocardiographic LV mass measurements is limited because acquiring anatomically correct apical views is often difficult. We tested the hypothesis that LV mass could be measured more accurately from real-time 3D (RT3D) data sets, which allow offline selection of nonforeshortened apical views, by comparing 2D and RT3D measurements against cardiac MR (CMR) measurements. Methods and Results— Echocardiographic imaging was performed (Philips 7500) in 21 patients referred for CMR imaging (1.5 T, GE). Apical 2- and 4-chamber views and RT3D data sets were acquired and analyzed by 2 independent observers. The RT3D data sets were used to select nonforeshortened apical 2- and 4-chamber views (3DQ-QLAB, Philips). In both 2D and RT3D images, LV long axis was measured; endocardial and epicardial boundaries were traced, and mass was calculated by use of the biplane method of disks. CMR LV mass values were obtained through standard techniques (MASS Analysis, GE). The RT3D data resulted in significantly larger LV long-axis dimensions and measurements of LV mass that correlated with CMR better ( r =0.90) than 2D ( r =0.79). The 2D technique underestimated LV mass (bias, 39%), whereas RT3D measurements showed only minimal bias (3%). The 95% limits of agreement were significantly wider for 2D (52%) than RT3D (28%). Additionally, the RT3D technique reduced the interobserver variability (37% to 7%) and intraobserver variability (19% to 8%). Conclusions— RT3D imaging provides the basis for accurate and reliable measurement of LV mass.

27 February 2009 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
GTGloria Tamborini
Gloria Tamborini
MMManuela Muratori
Manuela Muratori
DBDenise Brusoni
Denise Brusoni
FCFabrizio Celeste
Fabrizio Celeste
FMFrancesco Maffessanti
Francesco Maffessanti
MPMauro Pepi
Mauro Pepi
A reduction in tricuspid annular plane systolic excursion (TAPSE) and peak systolic velocity (PSV) of tricuspid annulus after cardiac surgery is a well-known phenomenon, even though its origin is not well established. Recently, a new three-dimensional (3D) echocardiographic software adapted for right ventricular (RV) analysis has been validated. Aims of this study were to evaluate RV function in patients with mitral valve prolapse undergoing surgical valvular repair and to compare and correlate 3D RV ejection fraction (RVEF) with TAPSE and PSV before and after surgery. Forty patients were studied by transthoracic 2D and 3D echocardiography pre- and 3, 6, and 12 months post-surgery. TAPSE (15.5 ± 3, 16.5 ± 3, and 18.5 ± 4 mm at 3, 6, and 12 months, respectively) and PSV (11.9 ± 2, 12 ± 2, and 12.8 ± 3 cm/s at 3, 6, and 12 months, respectively) were significantly ( P < 0.001) lower after surgery in comparison with pre-surgical values (TAPSE: 25.3 ± 4 mm; PSV: 17.8 ± 4 cm/s). On the contrary, pre-operative RVEF (58.4 ± 4%) did not change after surgery (56.9 ± 5, 59.5 ± 5, and 58.5 ± 5% at each step). Despite the post-operative reduction of RV performance along the long axis suggested by TAPSE and PSV, the absence of a decrease in 3D RVEF leads to caution in the interpretation of these 2D and Doppler parameters after cardiac surgery, supporting the hypothesis of geometrical rather than functional changes in the right ventricle.

23 August 2005 in Circulation
Verified
Journal Article
Closed access
PDF file
CCCristiana Corsi
Cristiana Corsi
RLRoberto M. Lang
Roberto M. Lang
FVFederico Veronesi
Federico Veronesi
LWLynn Weinert
Lynn Weinert
Enrico Gianluca CaianiEnrico Gianluca Caiani
Enrico Gianluca Caiani
VMVictor Mor-Avi
Victor Mor-Avi
Background—Real-time 3D echocardiographic (RT3DE) data sets contain dynamic volumetric information on cardiac function. However, quantification of left ventricular (LV) function from 3D echocardiographic data is performed on cut-planes extracted from the 3D data sets and thus does not fully exploit the volumetric information. Accordingly, we developed a volumetric analysis technique aimed at quantification of global and regional LV function.Methods and Results—RT3DE images obtained in 30 patients (Philips 7500) were analyzed by use of custom software based on the level-set approach for semiautomated detection of LV endocardial surface throughout the cardiac cycle, from which global and regional LV volume (LVV)–time and wall motion (WM)–time curves were obtained. The study design included 3 protocols. In protocol 1, time curves obtained in 16 patients were compared point-by-point with MRI data (linear regression and Bland-Altman analyses). Global LVV correlated highly with MRI (r=0.98;y=0.99x+2.3) with minimal bias (1.4 mL) and narrow limits of agreement (±20 mL). WM correlated highly only in basal and midventricular segments (r=0.88;y=0.85x+0.7). In protocol 2, we tested the ability of this technique to differentiate populations with known differences in LV function by studying 9 patients with dilated cardiomyopathy and 9 normal subjects. All calculated indices of global and regional systolic and diastolic LV function were significantly different between the groups. In protocol 3, we tested the feasibility of automated detection of regional WM abnormalities in 11 patients. In each segment, abnormality was detected when regional shortening fraction was below a threshold obtained in normal subjects. The automated detection agreed with expert interpretation of 2D WM in 86% of segments.Conclusions—Volumetric analysis of RT3DE data is clinically feasible and allows fast, semiautomated, dynamic measurement of LVV and automated detection of regional WM abnormalities.

1 February 2010 in Journal of the American Society of Echocardiography
Verified
Journal Article
Closed access
GTGloria Tamborini
Gloria Tamborini
NMNina Ajmone Marsan
Nina Ajmone Marsan
PGPaola Gripari
Paola Gripari
FMFrancesco Maffessanti
Francesco Maffessanti
DBDenise Brusoni
Denise Brusoni
MPMauro Pepi
Mauro Pepi

1 January 2013 in Journal of Biomechanics
Verified
Journal Article
Closed access
EVEmiliano Votta
Emiliano Votta
TLTrung Le
Trung Le
MSMarco Stevanella
Marco Stevanella
Laura FusiniLaura Fusini
Laura Fusini
Enrico Gianluca CaianiEnrico Gianluca Caiani
Enrico Gianluca Caiani
FSFotis Sotiropoulos
Fotis Sotiropoulos

17 July 2001 in Circulation
Verified
Journal Article
Closed access
PDF file
VMVictor Mor-Avi
Victor Mor-Avi
Enrico Gianluca CaianiEnrico Gianluca Caiani
Enrico Gianluca Caiani
KCKeith A. Collins
Keith A. Collins
CKClaudia E Korcarz
Claudia E Korcarz
JBJames E. Bednarz
James E. Bednarz
RLRoberto M. Lang
Roberto M. Lang
Background Echocardiographic contrast media have been used to assess myocardial perfusion and to enhance endocardial definition for improved assessment of left ventricular (LV) function. These methodologies, however, have been qualitative or have required extensive offline image analysis. Power modulation is a recently developed imaging technique that provides selective enhancement of microbubble-generated reflections. Our goal was to test the feasibility of using power modulation for combined quantitative assessment of myocardial perfusion and regional LV function in an animal model of acute ischemia. Methods and Results Coronary balloon occlusions were performed in 18 anesthetized pigs. Transthoracic power modulation images (Agilent 5500) were obtained during continuous intravenous infusion of the contrast agent Definity (DuPont) at baseline and during brief coronary occlusion and reperfusion and were analyzed with custom software. At each phase, myocardial perfusion was assessed by calculation, in 6 myocardial regions of interest, of mean pixel intensity and the rate of contrast replenishment after high-power ultrasound impulses. LV function was assessed by calculation of regional fractional area change from semiautomatically detected endocardial borders. All ischemic episodes caused detectable and reversible changes in perfusion and function. Perfusion defects, validated with fluorescent microspheres, were visualized in real time and confirmed by a significant decrease in pixel intensity in the left anterior descending coronary artery territory after balloon inflation and reduced rate of contrast replenishment. Fractional area change decreased significantly in ischemic segments and was restored with reperfusion. Conclusions Power modulation allows simultaneous online assessment of myocardial perfusion and regional LV wall motion, which may improve the echocardiographic diagnosis of myocardial ischemia.