Standard methods for chemical food safety testing in official laboratories rely largely on liquid or gas chromatography coupled with mass spectrometry. Although these methods are considered the gold standard for quantitative confirmatory analysis, they require sampling, transferring the samples to a central laboratory to be tested by highly trained personnel, and the use of expensive equipment. Therefore, there is an increasing demand for portable and handheld devices to provide rapid, efficient, and on-site screening of food contaminants. Recent technological advancements in the field include smartphone-based, microfluidic chip-based, and paper-based devices integrated with electrochemical and optical biosensing platforms. Furthermore, the potential application of portable mass spectrometers in food testing might bring the confirmatory analysis from the laboratory to the field in the future. Although such systems open new promising possibilities for portable food testing, few of these devices are commercially available. To understand why barriers remain, portable food analyzers reported in the literature over the last ten years were reviewed. To this end, the analytical performance of these devices and the extent they match the World Health Organization benchmark for diagnostic tests, i.e., the Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment-free, and Deliverable to end-users (ASSURED) criteria, was evaluated critically. A five-star scoring system was used to assess their potential to be implemented as food safety testing systems. The main findings highlight the need for concentrated efforts towards combining the best features of different technologies, to bridge technological gaps and meet commercialization requirements.
Paramagnetic microspheres can be used in planar array fluorescence immunoassays for single or multiplex screening of food contaminants. However, no confirmation of the molecular identity is obtained. Coated blade spray (CBS) is a direct ionization mass spectrometry (MS) technique, and when combined with triple quadrupole MS/MS, it allows for rapid confirmation of food contaminants. The lack of chromatography in CBS, though, compromises the specificity of the measurement for unequivocal identification of contaminants, based on the European Union (EU) regulation. Therefore, a rapid and easy-to-use immuno-magnetic blade spray (iMBS) method was developed in which immuno-enriched paramagnetic microspheres replace the coating of CBS. The iMBS-MS/MS method was fully optimized, validated in-house following the EU 2021/808 regulation, and benchmarked against a commercial lateral flow immunoassay (LFIA) for on-site screening of DA. The applicability of iMBS-MS/MS was further demonstrated by analyzing incurred mussel samples. The combination of immunorecognition and MS/MS detection in iMBS-MS/MS enhances the measurement’s selectivity, which is demonstrated by the rapid differentiation between the marine toxin domoic acid (DA) and its structural analog kainic acid (KA), which cannot be achieved with the LFIA alone. Interestingly, this first-ever reported iMBS-MS/MS method is generic and can be adapted to include any other immuno-captured food contaminant, provided that monoclonal antibodies are available, thus offering a complementary confirmatory analysis approach to multiplex immunoassay screening methods. Moreover, thanks to its speed of analysis, iMBS-MS/MS can bridge the logistics gap between future large-scale on-site testings using LFIAs and classical time-consuming confirmatory MS analysis performed in official control laboratories.
28 August 2020 in Analytical and Bioanalytical Chemistry
Lateral flow immunoassays (LFIAs) are widely used for rapid food safety screening analysis. Thanks to simplified protocols and smartphone readouts, LFIAs are expected to be increasingly used on-site, even by non-experts. As a typical follow-up in EU regulatory settings, suspect samples are sent to laboratories for confirmatory analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS). However, re-analysis by LC-MS/MS is laborious and time-consuming. In this work, an identification LFIA (ID-LFIA) approach followed by quadrupole-orbitrap MS or triple quadrupole MS/MS analysis is presented. As a proof of concept, a dedicated ID-LFIA strip was developed for the mycotoxin deoxynivalenol (DON) following its initial screening by a commercial smartphone LFIA. The ID-LFIA strip can be simply immersed in the same sample extract used for the smartphone LFIA screening, and next, DON is retrieved from the monoclonal antibody with a dissociation solution consisting of methanol/ammonia. The solution thus obtained was analyzed directly in MS in order to rapidly confirm the presence of DON and any cross-reacting species. The protocol developed is capable of coping with severe ion suppression caused by LFIA buffers and nitrocellulose substrate residues. Initial analysis of blank, spiked, and incurred samples showed that the newly developed ID-LFIA-MS method was able to confirm the presence or absence of mycotoxins in the samples previously analyzed by LFIA and also differentiate between DON and DON 3-glucoside yielding the positive screening result. The concept and technique developed are envisaged to complement on-site screening and confirmation of any low molecular weight contaminant in future food control frameworks.
In current food safety monitoring, lateral flow immunoassays (LFIAs) are widely used for rapid food contaminant screening. Recent advances include smartphone readouts, offering semi-quantitative analysis of LFIAs with time, location, and data transfer in case of on-site testing. Following the screening, the next step in the EU regulations is confirmation by, e.g., liquid chromatography-tandem mass spectrometry (LC-MS/MS). In this work, using direct analysis in real time ambient ionization and triple quadrupole MS/MS (DART-QqQ-MS/MS), we achieved rapid confirmation of the identity of the substance(s) causing the LFIA result. In the workflow proposed, an individual performs the (on-site) smartphone LFIA screening, and when the result is suspect, an identification LFIA (ID-LFIA) strip is developed with the same sample extract. The ID-LFIA can be dissociated and rapidly analyzed in a control laboratory with DART-QqQ-MS/MS. The ID-LFIA consists of multiple lines of monoclonal antibodies against the mycotoxin deoxynivalenol, acting as a bioaffinity trap. The ID-LFIA/DART-QqQ-MS/MS approach has been developed and validated, along with the screening smartphone LFIA, and has demonstrated its applicability by analyzing incurred and spiked samples. The developed approach has been critically compared with our previous direct electrospray ionization MS method and was found to provide highly complementary information on the total deoxynivalenol contamination in the sample.
Ensuring consumers' safety and maintaining regulatory compliance requires assessing the presence of pesticide residues in agricultural products. While sulfoxaflor, a widely used sulfoximine insecticide, is effective in pest control, its environmental impact has been increasingly scrutinized. Concerns over sulfoxaflor's harm to pollinators have led to its prohibition in the EU as of 2022, making its detection a critical aspect of environmental and food safety monitoring. Here, we present an innovative, highly sensitive, semi-quantitative indirect competitive lateral flow immunoassay (icLFIA) for detecting sulfoxaflor in flower leaves. This icLFIA achieves a visual limit of detection of 4 μg/L in plant extracts by implementing a highly specific monoclonal antibody. Moreover, it has demonstrated great reproducibility, making it an eco-conscious test for routine analysis at the point of need using a simple hot water extraction and incorporating sustainable packaging. The icLFIA has been tested on commercially available ornamental flowers and critically compared against an in-house confirmatory liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. This development offers a cost-effective and reliable solution for sulfoxaflor residue assessment. The combination with a straightforward and simplified extraction protocol for flower leaves, makes it accessible to non-experts (e.g. beekeepers).
Peptide and protein aggregation is a hallmark of numerous neurodegenerative diseases. However, the structural characterization of oligomeric intermediates remains challenging due to their low abundance, heterogenic nature, and the complexity of coinciding and transient reaction networks. Confining reactions to microenvironments, such as picoliter droplets in droplet-based microfluidics (DBMF), simplifies these networks and thereby enabling high-throughput analysis and controlled reaction kinetics. This study explores the integration of DBMF with ion mobility mass spectrometry (IM-MS) to probe aggregation kinetics in droplets. We address key technical challenges, including interference from the dispersed phase, surfactant, and DBMF device material, and we present optimization strategies for droplet generation, and surfactant concentration, to reduce contamination. Furthermore, we investigate instrumentation-based influences on ionization to improve signal stability. Using model peptides, bradykinin, leucine-enkephalin, and the aggregation-prone segment Ac-PHF6-NH₂ from the tau protein, we demonstrate the successful development of a sensitive method. Additionally, using the Ac-PHF6-NH₂ peptide, oligomeric transient species were probed and characterized by their IM and m/z values. This work demonstrates the potential of DBMF-IM-MS to study peptide aggregation in confined environments, providing insights into the formation of oligomeric species and laying the groundwork for studies on larger proteins and the development of therapeutic agents targeting aggregation using multi-channel devices.