Michel W.F. Nielen

Prof. Michel W.F. Nielen

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2007 in Analytica Chimica Acta
Verified
Journal Article
Closed access
MNMichel W.F. Nielen
Michel W.F. Nielen
MEM.C. van Engelen
M.C. van Engelen
RZR. Zuiderent
R. Zuiderent
RRR. Ramaker
R. Ramaker

13 November 2020 in Analytical Chemistry
Verified
Journal Article
Open access
GRGeorgina Ross
Georgina Ross
DFDaniel Filippini
Daniel Filippini
MNMichel W.F. Nielen
Michel W.F. Nielen
GSGert Ij. Salentijn
Gert Ij. Salentijn
Sandwich lateral flow immunoassays (LFIAs) are limited at high antigen concentrations by the hook effect, leading to a contradictory decrease in the test line (T) intensity and false-negative results. The hook effect is mainly associated with the loss of T, and research focuses on minimizing this effect. Nevertheless, the control line (C) intensity is also affected at higher analyte concentrations, undesirably influencing the T/C ratio in LFIA readers. The main aim of this work is to identify and understand these high antigen concentration effects in order to develop ubiquitous strategies to interpret and mitigate such effects. Four complementary experiments were performed: performance assessment of three different allergen LFIAs (two for hazelnut, one for peanut) over 0.075–3500 ppm, LFIAs with C only, surface plasmon resonance (SPR) binding experiments on the immobilized control antibody, and smartphone video recording of LFIAs during their development. As antigen concentrations increase, the C signal decreases before the T signal does, suggesting that distinct mechanisms underlie these intensity reductions. Reduced binding at the C occurred even in the absence of T, so the upfront T does not explain the loss of C. SPR confirmed that the C antibody favors binding with free labeled antibody compared with a labeled antibody–analyte complex, indicating that in antigen excess, binding is reduced at C before T. Finally, a smartphone-based video method was developed for dynamically monitoring the LFIA development in real time to distinguish between different concentration-dependent effects. Digitally analyzing the data allows clear differentiation of highly positive samples and false-negative samples and can indicate whether the LFIA is in the dynamic working range or at critically high concentrations. The aim of this work is to identify and understand such high antigen concentration effects in order to develop ubiquitous strategies to interpret and mitigate such effects.

8 December 2005 in Analytical Chemistry
Verified
Journal Article
Closed access
MNMichel W.F. Nielen
Michel W.F. Nielen
TBToine F. H. Bovee
Toine F. H. Bovee
MEMarcel C. van Engelen
Marcel C. van Engelen
PRPaula Rutgers
Paula Rutgers
AHAstrid R. M. Hamers
Astrid R. M. Hamers
RHRon Hoogenboom
Ron Hoogenboom

6 January 2008 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
MNMichel W.F. Nielen
Michel W.F. Nielen
JLJ. J. P. Lasaroms
J. J. P. Lasaroms
MEM. L. Essers
M. L. Essers
JOJ. E. Oosterink
J. E. Oosterink
TMT. Meijer
T. Meijer
ASA. A. M. Stolker
A. A. M. Stolker

17 June 2021 in Foods
Verified
Journal Article
Open access
PDF file
SJSafiye Jafari
Safiye Jafari
JGJulian Guercetti
Julian Guercetti
AGAriadni Geballa-Koukoula
Ariadni Geballa-Koukoula
Aristeidis TsagkarisAristeidis Tsagkaris
Aristeidis Tsagkaris
JNJoost Laurus Dinant Nelis
Joost Laurus Dinant Nelis
SSShana Sturla
Shana Sturla
Standard methods for chemical food safety testing in official laboratories rely largely on liquid or gas chromatography coupled with mass spectrometry. Although these methods are considered the gold standard for quantitative confirmatory analysis, they require sampling, transferring the samples to a central laboratory to be tested by highly trained personnel, and the use of expensive equipment. Therefore, there is an increasing demand for portable and handheld devices to provide rapid, efficient, and on-site screening of food contaminants. Recent technological advancements in the field include smartphone-based, microfluidic chip-based, and paper-based devices integrated with electrochemical and optical biosensing platforms. Furthermore, the potential application of portable mass spectrometers in food testing might bring the confirmatory analysis from the laboratory to the field in the future. Although such systems open new promising possibilities for portable food testing, few of these devices are commercially available. To understand why barriers remain, portable food analyzers reported in the literature over the last ten years were reviewed. To this end, the analytical performance of these devices and the extent they match the World Health Organization benchmark for diagnostic tests, i.e., the Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment-free, and Deliverable to end-users (ASSURED) criteria, was evaluated critically. A five-star scoring system was used to assess their potential to be implemented as food safety testing systems. The main findings highlight the need for concentrated efforts towards combining the best features of different technologies, to bridge technological gaps and meet commercialization requirements.

28 June 2014 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
SLSusann K. J. Ludwig
Susann K. J. Ludwig
HZHongying Zhu
Hongying Zhu
SPStephen Phillips
Stephen Phillips
ASAshutosh Shiledar
Ashutosh Shiledar
SFSteve Feng
Steve Feng
Aydogan OzcanAydogan Ozcan
Aydogan Ozcan