Alexandru Tudor

Alexandru Tudor

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2018 in Materials Today
Verified
Journal Article
Open access
ATAlexandru Tudor
Alexandru Tudor
CDColm Delaney
Colm Delaney
HZHongrui Zhang
Hongrui Zhang
ATAlex Thompson
Alex Thompson
VCVincenzo F. Curto
Vincenzo F. Curto
LFLarisa Florea
Larisa Florea

1 May 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Open access
TATuğçe Akyazi
Tuğçe Akyazi
ATAlexandru Tudor
Alexandru Tudor
DDDermot Diamond
Dermot Diamond
LBLourdes Basabe-Desmonts
Lourdes Basabe-Desmonts
LFLarisa Florea
Larisa Florea
Fernando Benito-LopezFernando Benito-Lopez
Fernando Benito-Lopez

1 August 2017 in Sensors and Actuators B: Chemical
Verified
Journal Article
Open access
ATAlexandru Tudor
Alexandru Tudor
JSJanire Saez
Janire Saez
LFLarisa Florea
Larisa Florea
Fernando Benito-LopezFernando Benito-Lopez
Fernando Benito-Lopez
Dermot DiamondDermot Diamond
Dermot Diamond

6 February 2016 in Sensors
Verified
Journal Article
Open access
PDF file
ATAlexandru Tudor
Alexandru Tudor
LFLarisa Florea
Larisa Florea
SGSimon Gallagher
Simon Gallagher
JBJohn Burns
John Burns
Dermot DiamondDermot Diamond
Dermot Diamond
Herein we describe poly(ionic liquid) hydrogel actuators that are capable of responding to multiple stimuli, namely temperature, ionic strength and white light irradiation. Using two starting materials, a crosslinked poly ionic liquid (PIL) and a linear poly(N-isopropylacrylamide-co-spiropyran-co-acrylic acid), several semi-interpenetrating (sIPN) hydrogels were synthesised. The dimensions of hydrogels discs were measured before and after applying the stimuli, to quantify their response. Samples composed of 100% crosslinked PIL alone showed an average area reduction value of ~53% when the temperature was raised from 20 °C to 70 °C, ~24% when immersed in 1% w/w NaF salt solution and no observable photo-response. In comparison, sIPNs containing 300% w/w linear polymer showed an average area reduction of ~45% when the temperature was raised from 20 °C to 70 °C, ~36% when immersed in 1% NaF w/w salt solution and ~10% after 30 min exposure to white light irradiation, respectively. Moreover, by varying the content of the linear component, fine-control over the photo-, thermo- and salt response, swelling-deswelling rate and mechanical properties of the resulting sIPN was achieved.

1 March 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Open access
JSJanire Saez
Janire Saez
TGTom Glennon
Tom Glennon
MCMonika Czugala
Monika Czugala
ATAlexandru Tudor
Alexandru Tudor
JDJens Ducreé
Jens Ducreé
Fernando Benito-LopezFernando Benito-Lopez
Fernando Benito-Lopez

1 August 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Open access
EMEva Marešová
Eva Marešová
DTDavid Tomeček
David Tomeček
PFPřEmysl Fitl
PřEmysl Fitl
JVJan Vlček
Jan Vlček
MNMichal Novotný
Michal Novotný
MVMartin Vrňata
Martin Vrňata