This study is a meta-analysis of randomized controlled trials comparing the efficacy of transcutaneous electrical nerve stimulation (TENS) to a control and to other nerve stimulation therapies (NSTs) for the treatment of chronic back pain. Citations were identified in MEDLINE, the Cochrane Library, Google Scholar, and ClinicalTrials.gov through June 2014 using the following keywords: nerve stimulation therapy, transcutaneous electrical nerve stimulation, back pain, chronic pain. Control treatments included sham, placebo, or medication only. Other NSTs included electroacupuncture, percutaneous electrical nerve stimulation, and percutaneous neuromodulation therapy. Twelve randomized controlled trials including 700 patients were included in the analysis. The efficacy of TENS was similar to that of control treatment for providing pain relief (standardized difference in means [SDM] = −0.20; 95% confidence interval [CI], −0.58 to 0.18; P = 0.293). Other types of NSTs were more effective than TENS in providing pain relief (SDM = 0.86; 95% CI, 0.15–1.57; P = 0.017). Transcutaneous electrical nerve stimulation was more effective than control treatment in improving functional disability only in patients with follow-up of less than 6 weeks (SDM = −1.24; 95% CI, −1.83 to −0.65; P < 0.001). There was no difference in functional disability outcomes between TENS and other NSTs. These results suggest that TENS does not improve symptoms of lower back pain, but may offer short-term improvement of functional disability.
Inadequate sitting posture can cause imbalanced loading on the spine and result in abnormal spinal pressure, which serves as the main risk factor contributing to irreversible and chronic spinal deformity. Therefore, sitting posture recognition is important for understanding people’s sitting behaviors and for correcting inadequate postures. Recently, wearable devices embedded with microelectromechanical systems (MEMs) sensors, such as inertial measurement units (IMUs), have received increased attention in human activity recognition. In this study, a wearable device embedded with IMUs and a machine learning algorithm were developed to classify seven static sitting postures: upright, slump, lean, right and left bending, and right and left twisting. Four 9-axis IMUs were uniformly distributed between thoracic and lumbar regions (T1-L5) and aligned on a sagittal plane to acquire kinematic information about subjects’ backs during static-dynamic alternating motions. Time-domain features served as inputs to a signal-based classification model that was developed using long short-term memory-based recurrent neural network (LSTM-RNN) architecture, and the model’s classification performance was used to evaluate the relevance between sensor signals and sitting postures. Overall results from performance evaluation tests indicate that this IMU-based measurement and LSTM-RNN structural scheme was appropriate for sitting posture recognition.
Combined usage of posterior lumbar interbody fusion and transpedicular fixation has been extensively used to treat the various lumbar degenerative disc diseases. The transpedicular fixator aims to increase stability and enhance the fusion rate. However, how the fused disc and bridged vertebrae respectively affect adjacent-segment diseases progression is not yet clear. Using a validated lumbosacral finite-element model, three variations at the L4-L5 segment were analyzed: 1) moderate disc degeneration, 2) instrumented with a stand-alone cage and pedicle screw fixators, and 3) with the cage only after fusion. The intersegmental angles, disc stresses, and facet loads were examined. Four motion tests, flexion, extension, bending, and twisting, were also simulated. The adjacent-segment disease was more severe at the cephalic segment than the caudal segment. After solid fusion and fixation, the increase in intersegmental angles, disc stresses and facet loads of the adjacent segments were about 57.6%, 47.3%, and 59.6%, respectively. However, these changes were reduced to 30.1%, 22.7%, and 27.0% after removal of the fixators. This was attributed to the differences between the biomechanical characteristics of the fusion and fixation mechanisms. Fixation superimposes a stiffer constraint on the mobility of the bridged segment than fusion. The current study suggested that the removal of spinal fixators after complete fusion could decrease the stress at adjacent segments. Through a minimally invasive procedure, we could reduce secondary damage to the paraspinal structures while removing the fixators, which is of utmost concern to surgeons.
The majority of compressive vertebral fractures in osteoporotic bone occur at the level of the thoracolumbar junction. Immediate decompression is often required in order to reduce the extent of neurological damage. This study evaluated four fixation methods for decompression in patients with thoracolumbar burst fractures, and presented the most suitable method for osteoporotic patients. A finite element model of a T7–L5 spinal segment was created and subjected to an L1 corpectomy to simulate a serious burst fracture. Five models were tested: a) intact spine; 2) two segment fixation (TSF), 3) up-three segment fixation (UTSF), below-three segment fixation (BTSF), and four segment fixation (FSF). The ROM, stiffness and compression ratio of the fractured vertebra were recorded under various loading conditions. The results of this study showed that the ROM of the FSF model was the lowest, and the ROMs of UTSF and BTSF models were similar but still greater than the TSF model. Decreasing the BMD to simulate osteoporotic bone resulted in a ROM for the four instrumented models that was higher than the normal bone model. Of all models, the FSF model had the highest stiffness at T12-L2 in extension and lateral bending. Similarly, the compression ratio of the FSF model at L1 was also higher than the other instrumented models. In conclusion, FSF fixation is suggested for patients with osteoporotic thoracolumbar burst fractures. For patients with normal bone quality, both UTSF and BTSF fixation provide an acceptable stiffness in extension and lateral bending, as well as a favorable compression ratio at L1.
Background: Effective treatment of low back pain (LBP) originating in the lumbar and sacroiliac joints is difficult to achieve. The objective of the current study was to compare the clinical effectiveness of radiofrequency (RF) neurotomy versus conservative nonsurgical approaches for the management of chronic lumbar and sacroiliac joint pain. Methods: The PICOS framework was adhered to (P [population]: patients with a history of chronic function-limiting lumbar and sacroiliac joint pain lasting at least 6 months; I [intervention]: RF neurotomy; C [comparator]: other nonsurgical treatments; O [outcomes]: the Oswestry Disability Index (ODI), measurement for pain, and a quality of life (QoL) questionnaire; S [study design]: meta-analysis). Two trained investigators systematically searched Medline, Cochrane, EMBASE, and ISI Web of Knowledge databases for relevant studies published in English through March 2019. Results: Patients treated with RF neurotomy (n = 528) had significantly greater improvement in ODI scores, pain scores and QoL measured by EQ-5D compared with controls (n = 457); however, significant heterogeneity was observed when data were pooled from eligible studies. In subgroup analyses, patients who received RF neurotomy had a significantly greater improvement in ODI scores compared with those with sham treatment. Patients treated with RF achieved significantly greater improvement in pain scores compared with controls who received sham treatment or medical treatment. In a subgroup analysis of pain in the sacroiliac joint and in lumbar facet joints, the RF neurotomy group achieved a significantly greater improvement in ODI score and pain scores compared with the control group. The ODI score and pain score were improved after 2 months of follow up in the analyses stratified by follow-up duration. Conclusions: Use of RF neurotomy as an intervention for chronic lumbar and sacroiliac joint pain led to improved function; however, larger, more directly comparable studies are needed to confirm this study's findings.
The purpose was to quantify the structural integrity of annulus fibrosis (AF) after injuries with repair. Punctures in the AF of 6-month-old porcine spine specimens were made with 18-, 20-, 22-, 24-, and 26-gauge needles. Leakage testing was performed immediately after needle puncture (Group 1), after the puncture was repaired with a modified purse-string suture (MPSS) (Group 2), and after needle puncture with immediate repair (Group 3). Punch injuries repaired with the MPSS alone, or with an AF graft and MPSS were also examined. There was no leakage from 26-gauge needle punctures. Pressures at which the nucleus pulposus leaked from the 24-, 22-, 20- and 18-gauge needle punctures (Group 1) were 4.28, 2.03, 1.27, and 1.06 MPa, respectively. Failure pressure after repair (Group 2, 3) was significantly greater than without (Group 1). Failure pressure in Group 3 was much greater than in Group 2 with 18- and 20-gauge punctures. Punch injury repaired with a graft and MPSS had significantly greater failure pressure than repair with MPSS alone (1.88 vs. 1.02 MPa, p = 0.0001). The MPSS can restore the mechanical integrity of the AF after needle puncture. An annular graft along with a MPSS may increase the structural integrity of the AF after a punch injury. As this was an acute animal study, the measurements and results may not directly translate to the human intervertebral disc.