Yueh-Ying Hsieh

Dr. Yueh-Ying Hsieh

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2017 in Clinical Biomechanics
Verified
Journal Article
Open access
YHYueh-Ying Hsieh
Yueh-Ying Hsieh
CCChia-Hsien Chen
Chia-Hsien Chen
FTFon-Yih Tsuang
Fon-Yih Tsuang
WLWu Lien-Chen
Wu Lien-Chen
SLShang-Chih Lin
Shang-Chih Lin
CCChang-Jung Chiang
Chang-Jung Chiang
Combined usage of posterior lumbar interbody fusion and transpedicular fixation has been extensively used to treat the various lumbar degenerative disc diseases. The transpedicular fixator aims to increase stability and enhance the fusion rate. However, how the fused disc and bridged vertebrae respectively affect adjacent-segment diseases progression is not yet clear. Using a validated lumbosacral finite-element model, three variations at the L4-L5 segment were analyzed: 1) moderate disc degeneration, 2) instrumented with a stand-alone cage and pedicle screw fixators, and 3) with the cage only after fusion. The intersegmental angles, disc stresses, and facet loads were examined. Four motion tests, flexion, extension, bending, and twisting, were also simulated. The adjacent-segment disease was more severe at the cephalic segment than the caudal segment. After solid fusion and fixation, the increase in intersegmental angles, disc stresses and facet loads of the adjacent segments were about 57.6%, 47.3%, and 59.6%, respectively. However, these changes were reduced to 30.1%, 22.7%, and 27.0% after removal of the fixators. This was attributed to the differences between the biomechanical characteristics of the fusion and fixation mechanisms. Fixation superimposes a stiffer constraint on the mobility of the bridged segment than fusion. The current study suggested that the removal of spinal fixators after complete fusion could decrease the stress at adjacent segments. Through a minimally invasive procedure, we could reduce secondary damage to the paraspinal structures while removing the fixators, which is of utmost concern to surgeons.

13 February 2020 in Polymers
Verified
Journal Article
Open access
PDF file
YHYu-Min Huang
Yu-Min Huang
YLYi-Cheng Lin
Yi-Cheng Lin
Chih-Yu ChenChih-Yu Chen
Chih-Yu Chen
YHYueh-Ying Hsieh
Yueh-Ying Hsieh
RCReui-Fong Chang
Reui-Fong Chang
Feng-Huei LinFeng-Huei Lin
Feng-Huei Lin
Healing of an anterior cruciate ligament graft in bone tunnel yields weaker fibrous scar tissue, which may prolong an already prolonged healing process within the tendon–bone interface. In this study, gelatin molecules were added to thermosensitive chitosan/β-glycerol phosphate disodium salt hydrogels to form chitosan/gelatin/β-glycerol phosphate (C/G/GP) hydrogels, which were applied to 0.1 mg/mL collagenase carrier in the tendon–bone junction. New Zealand white rabbit’s long digital extensor tendon was detached and translated into a 2.5-mm diameter tibial plateau tunnel. Thirty-six rabbits underwent bilateral surgery and hydrogel injection treatment with and without collagenase. Histological analyses revealed early healing and more bone formation at the tendon–bone interface after collagenase partial digestion. The area of metachromasia significantly increased in both 4-week and 8-week groups after collagenase treatment (p < 0.01). Micro computed tomography showed a significant increase in total bone volume and bone volume/tissue volume in the 8 weeks after collagenase treatment, compared with the control group. Load-to-failure was significantly higher in the treated group at 8 weeks (23.8 ± 8.13 N vs 14.3 ± 3.9 N; p = 0.008). Treatment with collagenase digestion resulted in a 66% increase in pull-out strength. In conclusion, injection of C/G/GP hydrogel with collagenase improves tendon-to-bone healing in a rabbit model.

15 June 2022 in Medicina
Verified
Journal Article
Open access
PDF file
WLWu Lien-Chen
Wu Lien-Chen
YHYueh-Ying Hsieh
Yueh-Ying Hsieh
FTFon-Yih Tsuang
Fon-Yih Tsuang
YCYueh-Feng Chiang
Yueh-Feng Chiang
CCChang-Jung Chiang
Chang-Jung Chiang
Background and Objectives: Using an appropriate torque to tighten set screws ensures the long-term stability of spinal posterior fixation devices. However, the recommended torque often varies between different devices and some devices do not state a recommended torque level. The purpose of this study is to evaluate the effect of set screw torque on the overall construct stability and fatigue life. Materials and Methods: Two commercial pedicle screw systems with different designs for the contact interface between the set screw and rod (Group A: plane contact, Group B: line contact) were assembled using torque wrenches provided with the devices to insert the set screws and tighten to the device specifications. The axial gipping capacity and dynamic mechanical stability of each bilateral construct were assessed in accordance with ASTM F1798 and ASTM F1717. Results: Increasing or decreasing the torque on the set screw by 1 Nm from the recommended level did not have a significant effect on the axial gripping capacity or fatigue strength of Group A (p > 0.05). For Group B, over-tightening the set screw by 1 Nm did cause a significant reduction in the fatigue strength. Conclusions: Excessive torque can damage the rod surface and cause premature failure. When insertion using a manual driver is preferred, a plane contact interface between the set screw and rod can reduce damage to the rod surface when the set screw is over-torqued.

21 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YHYueh-Ying Hsieh
Yueh-Ying Hsieh
YKYi-Jie Kuo
Yi-Jie Kuo
CCChia-Hsien Chen
Chia-Hsien Chen
WLWu Lien-Chen
Wu Lien-Chen
CCChang-Jung Chiang
Chang-Jung Chiang
Chunli LinChunli Lin
Chunli Lin
A hybrid fixation method, using a combination of vertebroplasty and cement-augmented screws, has been demonstrated as a useful technique for securing osteoporotic burst fractures. The purpose of this study was to assess changes in the range of motion (ROM) and stress in the spine after treating a lumbar burst fracture with this hybrid method. Five finite element models were developed: (a) intact lumbar spine (INT), (b) INT with vertebroplasty at L3 (AwC), (c) two-segment fixation of AwC (AwC-TSF), (d) AwC-TSF model with cement-augmented screws (AwC-TSF-S), and (e) INT with an L3 burst fracture treated with two-segment fixation (TSF). After loading, the models were evaluated in terms of the ROM of each motion segment, stiffness of fusion segments, and stresses on the endplates and screws. The results showed that the TSF model has a larger ROM at the instrumented segments than both the AwC-TSF and AwC-TSF-S models. The stiffness at L2–L4 under extension and lateral bending in AwC-TSF, AwC-TSF-S and TSF was approximately nine times greater than the INT model. In conclusion, the hybrid fixation method (AwC-TSF-S) results in a stiffer construct and lower ROM at instrumented segments, which may also reduce the risk of fracture of adjacent vertebrae.

20 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YHYueh-Ying Hsieh
Yueh-Ying Hsieh
WLWu Lien-Chen
Wu Lien-Chen
FTFon-Yih Tsuang
Fon-Yih Tsuang
CCChia-Hsien Chen
Chia-Hsien Chen
CCChang-Jung Chiang
Chang-Jung Chiang
Suture anchor fixation is a common method for securing bone and soft tissue in the body, with proven applications in the hip, elbow, hand, knee and foot. A critical limiting factor of suture anchors is the pull-out strength, particularly in suboptimal bone. This study introduces a novel 3D printed threadless suture anchor with a rectangular cross-section. The titanium anchor was designed with surface fenestration and a porous central core to improve bone ingrowth. The aim of this study was to compare the pull-out properties of the novel threadless anchor with a traditional circular threaded suture anchor. The anchors were inserted into a 0.24 g/cm3 synthetic cancellous bone block at angles of 90° and 135° to the surface. The sutures were pulled at 180° (parallel) to the surface under a static pull test (anchor pullout) and cyclic load test using a tensile testing machine. Under the static load, the greatest pullout strength was seen with the novel threadless anchor inserted at 90° (mean, 105.6 N; standard deviation [SD], 3.5 N). The weakest pullout strength was seen with the threaded anchor inserted at 90° (mean, 87.9 N; SD, 4.1 N). In the cyclic load test, all six of the threaded anchors with a 90° insertion angle pulled out after 18 cycles (70 N). All of the threadless anchors inserted at 90° survived the cyclic test (90 N). In conclusion, the novel threadless suture anchor with rectangular cross-section and traditional threaded suture anchor had similar pullout survivorship when inserted at either 90° or 135°. In addition, the 3D printed threadless anchor has the potential for good bone integration to improve long-term stabilization.

13 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WLWu Lien-Chen
Wu Lien-Chen
YHYueh-Ying Hsieh
Yueh-Ying Hsieh
FTFon-Yih Tsuang
Fon-Yih Tsuang
YKYi-Jie Kuo
Yi-Jie Kuo
CCChang-Jung Chiang
Chang-Jung Chiang
Self-tapping screws are commonly used in trauma and maxillofacial surgery and are increasingly used for pedicle screw insertions. In order to evaluate how the quantity and length of cutting flutes on self-tapping pedicle screws affect the insertion torque and pullout strength, eight different self-tapping pedicle screw designs were evaluated. All screws had a threaded length of 35 mm and featured variations in the number of leads, as well as the length and quantity of cutting flutes. Five samples of each design were inserted into pre-drilled, untapped holes (ø2.7 mm, length 35 mm) in sawbone blocks of density 20 PCF. The insertion torque and pullout strength were measured according to ASTM F543. The results showed that screws with a longer cutting flute of 9.5 mm had a lower mean maximum insertion torque than screws with shorter 2.9 mm cutting flutes. Pedicle screws with a double-lead thread design had a greater insertion torque than their single-lead counterparts, and the use of three cutting flutes produced a lower torque than two cutting flutes. The results demonstrated a greater pullout strength in screws with a single-lead thread rather than a double-lead, three cutting flutes instead of two, and a longer length for the cutting flute. In conclusion, to provide immediate stability and reduce the surgical insertion time, a single-lead, self-tapping pedicle screw incorporating three long cutting flutes is recommended because of the significantly greater pullout strength. This design could also reduce the risk of implant loosening in comparison to double-lead, self-tapping pedicle screw designs.