Kelly L. Stewart

Dr. Kelly L. Stewart

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2019 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
ABAaron Bach
Aaron Bach
MMMatthew J. Maley
Matthew J. Maley
GMGeoffrey M. Minett
Geoffrey M. Minett
SZStephanie A. Zietek
Stephanie A. Zietek
KSKelly L. Stewart
Kelly L. Stewart
ISIan Stewart
Ian Stewart
Objective: The use of personal cooling systems to mitigate heat strain on first-responders achieves two potential performance benefits relative to the absence of such cooling: (1) the completion of a workload with less effort; and/or (2) the completion of a greater workload for the same effort. Currently, claims made by manufacturers regarding the capability of their products for use in conjunction with chemical/biological protective clothing remain largely unsubstantiated. The purpose of this investigation was to evaluate the means by which heat strain can be alleviated during uncompensable heat stress in chemical/biological clothing, using the ASTM F2300-10 methodology. Methods: Eight healthy males completed five trials of continuous walking (4.5 km h−1; 35°C; 49% RH) for up to 120 min while wearing one of four cooling systems and/or a National Fire and Protection Association 1994 Class-3 chemical/biological ensemble. The four cooling methods (ice vest [IV], phase-change vest [PCM], water-perfused suit [WS], and combination ice slurry/ice vest [SLIV]) and no cooling (CON). Results: We observed significant improvements in trial times for IV (18 ± 10 min), PCM (20 ± 10 min) and SLIV (22 ± 10 min), but no differences for WS (4 ± 7 min). Heart rate, rectal, mean skin, and body temperatures were significantly lower in all cooling conditions relative to control at various matched time points in the first 60 min of exercise. Thermal sensation, comfort and perceived exertion all had significant main effects for condition, and time, there were no differences in their respective interactions. Conclusion: The IV, PCM, and SLIV produced lower heart rate, mean skin, rectal and mean body temperatures in addition to improved work times compared to control. The WS did not improve work times possibly as a result of the cooling capacity of the suit abating, and magnifying thermal insulation. Considering the added time and resources required to implement combination cooling in the form of ice slurry and ice vest (SLIV), there was no significant additive effect for perception, cardiovascular strain, rectal temperature and total trial time relative to the phase change vest or ice vest alone. This may be a product of a “ceiling” effect for work limit set to 120 min as part of ASTM F2300-10.

21 February 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ISIan Stewart
Ian Stewart
KSKelly L. Stewart
Kelly L. Stewart
CWCharles J Worringham
Charles J Worringham
JCJoseph T Costello
Joseph T Costello
Explosive ordnance disposal (EOD) technicians are required to wear protective clothing to protect themselves from the threat of overpressure, fragmentation, impact and heat. The engineering requirements to minimise these threats results in an extremely heavy and cumbersome clothing ensemble that increases the internal heat generation of the wearer, while the clothing’s thermal properties reduce heat dissipation. This study aimed to evaluate the heat strain encountered wearing EOD protective clothing in simulated environmental extremes across a range of differing work intensities. Eight healthy males [age 25±6 years (mean ± sd), height 180±7 cm, body mass 79±9 kg, V˙O2max 57±6 ml.kg−1.min−1] undertook nine trials while wearing an EOD9 suit (weighing 33.4 kg). The trials involved walking on a treadmill at 2.5, 4 and 5.5 km⋅h−1 at each of the following environmental conditions, 21, 30 and 37°C wet bulb globe temperature (WBGT) in a randomised controlled crossover design. The trials were ceased if the participants’ core temperature reached 39°C, if heart rate exceeded 90% of maximum, if walking time reached 60 minutes or due to fatigue/nausea. Tolerance times ranged from 10–60 minutes and were significantly reduced in the higher walking speeds and environmental conditions. In a total of 15 trials (21%) participants completed 60 minutes of walking; however, this was predominantly at the slower walking speeds in the 21°C WBGT environment. Of the remaining 57 trials, 50 were ceased, due to attainment of 90% maximal heart rate. These near maximal heart rates resulted in moderate-high levels of physiological strain in all trials, despite core temperature only reaching 39°C in one of the 72 trials.

22 January 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MMMatthew J Maley
Matthew J Maley
GMGeoffrey M Minett
Geoffrey M Minett
ABAaron Bach
Aaron Bach
SZStephanie A Zietek
Stephanie A Zietek
KSKelly L. Stewart
Kelly L. Stewart
ISIan Stewart
Ian Stewart
The present study aimed to compare a range of cooling methods possibly utilised by occupational workers, focusing on their effect on body temperature, perception and manual dexterity. Ten male participants completed eight trials involving 30 min of seated rest followed by 30 min of cooling or control of no cooling (CON) (34°C, 58% relative humidity). The cooling methods utilised were: ice cooling vest (CV0), phase change cooling vest melting at 14°C (CV14), evaporative cooling vest (CVEV), arm immersion in 10°C water (AI), portable water-perfused suit (WPS), heliox inhalation (HE) and ice slushy ingestion (SL). Immediately before and after cooling, participants were assessed for fine (Purdue pegboard task) and gross (grip and pinch strength) manual dexterity. Rectal and skin temperature, as well as thermal sensation and comfort, were monitored throughout. Compared with CON, SL was the only method to reduce rectal temperature (P = 0.012). All externally applied cooling methods reduced skin temperature (P<0.05), though CV0 resulted in the lowest skin temperature versus other cooling methods. Participants felt cooler with CV0, CV14, WPS, AI and SL (P0.05). The present study observed that ice ingestion or ice applied to the skin produced the greatest effect on rectal and skin temperature, respectively. AI should not be utilised if workers require subsequent fine manual dexterity. These results will help inform future studies investigating appropriate pre-cooling methods for the occupational worker.

1 January 2015 in BioMed Research International
Verified
Journal Article
Open access
JCJoseph T. Costello
Joseph T. Costello
KSKelly L. Stewart
Kelly L. Stewart
ISIan Stewart
Ian Stewart
This study evaluated the physiological tolerance times when wearing explosive and chemical (>35 kg) personal protective equipment (PPE) in simulated environmental extremes across a range of differing work intensities. Twelve healthy males undertook nine trials which involved walking on a treadmill at 2.5, 4, and 5.5 km·h−1in the following environmental conditions, 21, 30, and 37°C wet bulb globe temperature (WBGT). Participants exercised for 60 min or until volitional fatigue, core temperature reached 39°C, or heart rate exceeded 90% of maximum. Tolerance time, core temperature, skin temperature, mean body temperature, heart rate, and body mass loss were measured. Exercise time was reduced in the higher WBGT environments (WBGT37 < WBGT30 < WBGT21;P< 0.05) and work intensities (5.5 < 4 < 2.5 km·h−1;P< 0.001). The majority of trials (85/108; 78.7%) were terminated due to participant’s heart rate exceeding 90% of their maximum. A total of eight trials (7.4%) lasted the full duration. Only nine (8.3%) trials were terminated due to volitional fatigue and six (5.6%) due to core temperatures in excess of 39°C. These results demonstrate that physiological tolerance times are influenced by the external environment and workload and that cardiovascular strain is the limiting factor to work tolerance when wearing this heavy multilayered PPE.

ISIan Stewart
Ian Stewart
KSKelly L. Stewart
Kelly L. Stewart
This study examined the capabilities of an ultraendurance athlete to self-regulate their diet during an attempt on the record for the longest period of stationary cycling. The attempt required the athlete to complete at least 20 km/hr, with a 15 minute break allowed every eight hours. Laboratory tests determined a heart rate-oxygen consumption regression equation enabling calculation of energy expenditure from heart rate during the attempt. Energy intake was determined by a non-weighed dietary record collected at the time of consumption. The athlete completed 46.7 hours, covering 1126 km, at a speed of 24 ± 1.6 km/hr. He expended 14486 kcal and consumed 11098 kcal resulting in an energy deficit (-3290 kcal) and a weight loss (-0.55 kg). The carbohydrate (42 ± 32 g/hr), water (422 ± 441 ml/hr), and sodium (306 ± 465 mg/hr) intake were all below current recommendations. The athlete was unable to self-regulate his diet or exercise intensity to prevent a negative energy balance.

1 January 2022 in Applied Ergonomics
Verified
Journal Article
Closed access
CAChristopher A.J. Anderson
Christopher A.J. Anderson
ISIan Stewart
Ian Stewart
KSKelly L. Stewart
Kelly L. Stewart
DLDenise M. Linnane
Denise M. Linnane
MPMark J. Patterson
Mark J. Patterson
AHAndrew Hunt
Andrew Hunt