Aaron Bach

Dr. Aaron Bach

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in Journal of Thermal Biology
Verified
Journal Article
Open access
DCDanilo Reis Coimbra
Danilo Reis Coimbra
JCJoseph T. Costello
Joseph T. Costello
CBCiro Jose Brito
Ciro Jose Brito
JAJakub Grzegorz Adamczyk
Jakub Grzegorz Adamczyk
KAKurt Ammer
Kurt Ammer
MSManuel Sillero-Quintana
Manuel Sillero-Quintana
The importance of using infrared thermography (IRT) to assess skin temperature (tsk) is increasing in clinical settings. Recently, its use has been increasing in sports and exercise medicine; however, no consensus guideline exists to address the methods for collecting data in such situations. The aim of this study was to develop a checklist for the collection of tsk using IRT in sports and exercise medicine. We carried out a Delphi study to set a checklist based on consensus agreement from leading experts in the field. Panelists (n = 24) representing the areas of sport science (n = 8; 33%), physiology (n = 7; 29%), physiotherapy (n = 3; 13%) and medicine (n = 6; 25%), from 13 different countries completed the Delphi process. An initial list of 16 points was proposed which was rated and commented on by panelists in three rounds of anonymous surveys following a standard Delphi procedure. The panel reached consensus on 15 items which encompassed the participants' demographic information, camera/room or environment setup and recording/analysis of tsk using IRT. The results of the Delphi produced the checklist entitled "Thermographic Imaging in Sports and Exercise Medicine (TISEM)" which is a proposal to standardize the collection and analysis of tsk data using IRT. It is intended that the TISEM can also be applied to evaluate bias in thermographic studies and to guide practitioners in the use of this technique.

19 July 2022 in PM&R
Verified
Journal Article
Closed access
DBDavid N. Borg
David N. Borg
ABAaron Bach
Aaron Bach
JOJulia L. O'BRien
Julia L. O'BRien
Kristin SainaniKristin Sainani
Kristin Sainani

19 March 2024 in Scandinavian Journal of Medicine & Science in Sports
Verified
Journal Article
Open access
DBDavid N. Borg
David N. Borg
FIFranco M. Impellizzeri
Franco M. Impellizzeri
SBSamantha J. Borg
Samantha J. Borg
KHKate P Hutchins
Kate P Hutchins
ISIan Stewart
Ian Stewart
ABAdrian G. Barnett
Adrian G. Barnett
Aim: Prediction intervals are a useful measure of uncertainty for meta‐analyses that capture the likely effect size of a new (similar) study based on the included studies. In comparison, confidence intervals reflect the uncertainty around the point estimate but provide an incomplete summary of the underlying heterogeneity in the meta‐analysis. This study aimed to estimate (i) the proportion of meta‐analysis studies that report a prediction interval in sports medicine; and (ii) the proportion of studies with a discrepancy between the reported confidence interval and a calculated prediction interval.Methods: We screened, at random, 1500 meta‐analysis studies published between 2012 and 2022 in highly ranked sports medicine and medical journals. Articles that used a random effect meta‐analysis model were included in the study. We randomly selected one meta‐analysis from each article to extract data from, which included the number of estimates, the pooled effect, and the confidence and prediction interval.Results: Of the 1500 articles screened, 866 (514 from sports medicine) used a random effect model. The probability of a prediction interval being reported in sports medicine was 1.7% (95% CI = 0.9%, 3.3%). In medicine the probability was 3.9% (95% CI = 2.4%, 6.6%). A prediction interval was able to be calculated for 220 sports medicine studies. For 60% of these studies, there was a discrepancy in study findings between the reported confidence interval and the calculated prediction interval. Prediction intervals were 3.4 times wider than confidence intervals.Conclusion: Very few meta‐analyses report prediction intervals and hence are prone to missing the impact of between‐study heterogeneity on the overall conclusions. The widespread misinterpretation of random effect meta‐analyses could mean that potentially harmful treatments, or those lacking a sufficient evidence base, are being used in practice. Authors, reviewers, and editors should be aware of the importance of prediction intervals.

22 June 2021 in Sports Medicine - Open
Verified
Journal Article
Open access
PDF file
KHKate P Hutchins
Kate P Hutchins
DBDavid N. Borg
David N. Borg
ABAaron Bach
Aaron Bach
JBJoshua J. Bon
Joshua J. Bon
GMGeoffrey M. Minett
Geoffrey M. Minett
ISIan Stewart
Ian Stewart
Background: Despite an increasing rate of women participating in professional sports, emergency services, and military settings where they are exposed to exertional heat stress, our understanding of female thermoregulation and the detrimental effects of heat on women’s performance, especially regarding the menstrual cycle, is limited. This review aimed to quantify the representation of women in exercise thermoregulation research between 2010 and 2019 and the frequency that these articles reported details pertaining to female participants’ menstrual cycle to determine the volume of novel research that is directly relevant to this growing population. Methods: Original exercise thermoregulatory studies published in three major sports medicine databases (PubMed, MEDLINE, and SPORTDiscus) between 2010 and 2019 were surveyed. Articles were screened to determine the number of female and male participants in the study and whether studies involving women reported menstrual orientation or phase. Research involving healthy adult participants and an exercise protocol with a thermoregulatory outcome measure were included in the review. Results: A total of 1407 articles were included in the review, involving 28,030 participants. The annual representation of women ranged from a mean of 11.6% [95% credible interval (CI); 9.2, 14.3] to 17.8% [95% CI; 15.2, 20.6] across the 10 years, indicating studies predominantly included men. Nonetheless, there was a small statistical increase in the overall proportion of women, with a mean overall proportion change of 0.7% [95% CI; 0.2, 1.2] per year. The increase appeared to be driven by a reduction in the number of studies including only men, rather than studies including more women alongside men, or increased women-only studies. Less than one third of articles involving women reported the menstrual orientation of participants and less than one quarter reported both menstrual orientation and phase. Summary/Conclusion: This study shows that women were proportionally underrepresented in exercise thermoregulation research during the past decade and the majority of studies did not report menstrual cycle details of female participants. Researchers should consider including women in future work where their inclusion could contribute meaningful data that enhance the evidence-based and ultimately improves our comprehension of women’s thermal physiology.

6 February 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ABAaron Bach
Aaron Bach
ISIan Stewart
Ian Stewart
ADAlice E. Disher
Alice E. Disher
JCJoseph T. Costello
Joseph T. Costello
Skin temperature assessment has historically been undertaken with conductive devices affixed to the skin. With the development of technology, infrared devices are increasingly utilised in the measurement of skin temperature. Therefore, our purpose was to evaluate the agreement between four skin temperature devices at rest, during exercise in the heat, and recovery. Mean skin temperature ( ) was assessed in thirty healthy males during 30 min rest (24.0 ± 1.2°C, 56 ± 8%), 30 min cycle in the heat (38.0 ± 0.5°C, 41 ± 2%), and 45 min recovery (24.0 ± 1.3°C, 56 ± 9%). was assessed at four sites using two conductive devices (thermistors, iButtons) and two infrared devices (infrared thermometer, infrared camera). Bland–Altman plots demonstrated mean bias ± limits of agreement between the thermistors and iButtons as follows (rest, exercise, recovery): -0.01 ± 0.04, 0.26 ± 0.85, -0.37 ± 0.98°C; thermistors and infrared thermometer: 0.34 ± 0.44, -0.44 ± 1.23, -1.04 ± 1.75°C; thermistors and infrared camera (rest, recovery): 0.83 ± 0.77, 1.88 ± 1.87°C. Pairwise comparisons of found significant differences (p < 0.05) between thermistors and both infrared devices during resting conditions, and significant differences between the thermistors and all other devices tested during exercise in the heat and recovery. These results indicate poor agreement between conductive and infrared devices at rest, during exercise in the heat, and subsequent recovery. Infrared devices may not be suitable for monitoring in the presence of, or following, metabolic and environmental induced heat stress.

12 April 2019 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
ABAaron Bach
Aaron Bach
MMMatthew J. Maley
Matthew J. Maley
GMGeoffrey M. Minett
Geoffrey M. Minett
SZStephanie A. Zietek
Stephanie A. Zietek
KSKelly L. Stewart
Kelly L. Stewart
ISIan Stewart
Ian Stewart
Objective: The use of personal cooling systems to mitigate heat strain on first-responders achieves two potential performance benefits relative to the absence of such cooling: (1) the completion of a workload with less effort; and/or (2) the completion of a greater workload for the same effort. Currently, claims made by manufacturers regarding the capability of their products for use in conjunction with chemical/biological protective clothing remain largely unsubstantiated. The purpose of this investigation was to evaluate the means by which heat strain can be alleviated during uncompensable heat stress in chemical/biological clothing, using the ASTM F2300-10 methodology. Methods: Eight healthy males completed five trials of continuous walking (4.5 km h−1; 35°C; 49% RH) for up to 120 min while wearing one of four cooling systems and/or a National Fire and Protection Association 1994 Class-3 chemical/biological ensemble. The four cooling methods (ice vest [IV], phase-change vest [PCM], water-perfused suit [WS], and combination ice slurry/ice vest [SLIV]) and no cooling (CON). Results: We observed significant improvements in trial times for IV (18 ± 10 min), PCM (20 ± 10 min) and SLIV (22 ± 10 min), but no differences for WS (4 ± 7 min). Heart rate, rectal, mean skin, and body temperatures were significantly lower in all cooling conditions relative to control at various matched time points in the first 60 min of exercise. Thermal sensation, comfort and perceived exertion all had significant main effects for condition, and time, there were no differences in their respective interactions. Conclusion: The IV, PCM, and SLIV produced lower heart rate, mean skin, rectal and mean body temperatures in addition to improved work times compared to control. The WS did not improve work times possibly as a result of the cooling capacity of the suit abating, and magnifying thermal insulation. Considering the added time and resources required to implement combination cooling in the form of ice slurry and ice vest (SLIV), there was no significant additive effect for perception, cardiovascular strain, rectal temperature and total trial time relative to the phase change vest or ice vest alone. This may be a product of a “ceiling” effect for work limit set to 120 min as part of ASTM F2300-10.