Maria-Letizia Raffa

Dr. Maria-Letizia Raffa

Laboratoire QUARTZ, ISAE-SUPMECA, 93400 Saint-Ouen, France
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2020 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
Maria-Letizia RaffaMaria-Letizia Raffa
Maria-Letizia Raffa
Vu-Hieu NguyenVu-Hieu Nguyen
Vu-Hieu Nguyen
PHPhilippe Hernigou
Philippe Hernigou
CFCharles‐Henri Flouzat‐Lachaniette
Charles‐Henri Flouzat‐Lachaniette
GHGuillaume Haiat
Guillaume Haiat

1 June 2016 in International Journal of Solids and Structures
Verified
Journal Article
Closed access
Maria-Letizia RaffaMaria-Letizia Raffa
Maria-Letizia Raffa
FLFrédéric Lebon
Frédéric Lebon
GVGiuseppe Vairo
Giuseppe Vairo

29 October 2014 in The Open Civil Engineering Journal
Verified
Journal Article
Open access
FFFazia Fouchal
Fazia Fouchal
FLFrédéric Lebonb
Frédéric Lebonb
Maria-Letizia RaffaMaria-Letizia Raffa
Maria-Letizia Raffa
GVGiuseppe Vairo
Giuseppe Vairo
In this paper an interface model accounting for roughness and micro-cracks is presented and applied to masonry-like structures. The model is consistently derived by coupling a homogenization approach and arguments of asymptotic analyses. A numerical procedure is introduced and numerical results, based on a finite element formulation, are successfully compared with experimental data , obtained on masonry samples undergoing to shear tests. Finally, a parametric numerical analysis is proposed, highlighting the influence of the roughness features on the interface response.

3 December 2019 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
Maria-Letizia RaffaMaria-Letizia Raffa
Maria-Letizia Raffa
Vu-Hieu NguyenVu-Hieu Nguyen
Vu-Hieu Nguyen
GHGuillaume Haiat
Guillaume Haiat
Background: The surgical success of cementless implants is determined by the evolution of the biomechanical properties of the bone–implant interface (BII). One difficulty to model the biomechanical behavior of the BII comes from the implant surface roughness and from the partial contact between bone tissue and the implant. The determination of the constitutive law of the BII would be of interest in the context of implant finite element (FE) modeling to take into account the imperfect characteristics of the BII. The aim of the present study is to determine an effective contact stiffness $$\left( {K_{c}^{\text{FEM}} } \right)$$KcFEM of an osseointegrated BII accounting for its micromechanical features such as surface roughness, bone–implant contact ratio (BIC) and periprosthetic bone properties. To do so, a 2D FE model of the BII under normal contact conditions was developed and was used to determine the behavior of $$K_{c}^{\text{FEM}}$$KcFEM .Results: The model is validated by comparison with three analytical schemes based on micromechanical homogenization including two Lekesiz’s models (considering interacting and non-interacting micro-cracks) and a Kachanov’s model. $$K_{c}^{\text{FEM}}$$KcFEM is found to be comprised between 1013and 1015 N/m3according to the properties of the BII. $$K_{c}^{\text{FEM}}$$KcFEM is shown to increase nonlinearly as a function of the BIC and to decrease as a function of the roughness amplitude for high BIC values (above around 20%). Moreover, $$K_{c}^{\text{FEM}}$$KcFEM decreases as a function of the roughness wavelength and increases linearly as a function of the Young’s modulus of periprosthetic bone tissue.Conclusions: These results open new paths in implant biomechanical modeling since this model may be used in future macroscopic finite element models modeling the bone–implant system to replace perfectly rigid BII conditions.

3 August 2017 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
Vu-Hieu NguyenVu-Hieu Nguyen
Vu-Hieu Nguyen
GRGiuseppe Rosi
Giuseppe Rosi
SNSalah Naili
Salah Naili
AMAdrien Michel
Adrien Michel
Maria-Letizia RaffaMaria-Letizia Raffa
Maria-Letizia Raffa
GHGuillaume Haiat
Guillaume Haiat
Although the biomechanical behavior of the acetabular cup (AC) implant is determinant for the surgical success, it remains difficult to be assessed due to the multiscale and anisotropic nature of bone tissue. The aim of the present study was to investigate the influence of the anisotropic properties of peri-implant trabecular bone tissue on the biomechanical behavior of the AC implant at the macroscopic scale. Thirteen bovine trabecular bone samples were imaged using micro-computed tomography (μCT) with a resolution of 18 μm. The anisotropic biomechanical properties of each sample were determined at the scale of the centimeter based on a dedicated method using asymptotic homogenization. The material properties obtained with this multiscale approach were used as input data in a 3D finite element model to simulate the macroscopic mechanical behavior of the AC implant under different loading conditions. The largest stress and strain magnitudes were found around the equatorial rim and in the polar area of the AC implant. All macroscopic stiffness quantities were significantly correlated (R2 > 0.85, p < 6.5 e-6) with BV/TV (bone volume/total volume). Moreover, the maximum value of the von Mises stress field was significantly correlated with BV/TV (R2 > 0.61, p < 1.6 e-3) and was always found at the bone-implant interface. However, the mean value of the microscopic stress (at the scale of the trabeculae) decrease as a function of BV/TV for vertical and torsional loading and do not depend on BV/TV for horizontal loading. These results highlight the importance of the anisotropic properties of bone tissue.