Jesús González Ruíz

Prof. Jesús González Ruíz

Biomaterial Center, University of Havana

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2025 in Materials
Verified
Journal Article
Open access
PDF file
PMPedro Ernesto González Mederos
Pedro Ernesto González Mederos
JGJennifer Rodríguez Guerra
Jennifer Rodríguez Guerra
JRJesús González Ruíz
Jesús González Ruíz
APAlberto Picardo
Alberto Picardo
Yadir Torres HernándezYadir Torres Hernández
Yadir Torres Hernández
It is widely recognized that excessive stress and/or strain can lead to peri-implant bone atrophy; therefore, the clinical success of dental implants is intrinsically related to their biomechanical behavior. This study evaluates the influence of the diameter, length, and material [Ti6Al4V (α+β Ti) and Ti35Nb7Zr5Ta (β-Ti)] of a novel cylindrical dental implant on stress and strain levels within maxillary bone of type II quality. The implant design aims to ensure an appropriate distribution of stresses and strains within the peri-implant bone structures (cortical and trabecular bones) while also facilitating surgical machining by requiring a simple, linear, and less expensive bone incision. This approach minimizes the risk of thermal necrosis, a common complication in osteotomies for conical implants that can lead to peri-implant bone loss. Using finite element analysis, stress and strain patterns were evaluated in the maxillary second premolar region under static delayed loading. The results reveal that the cortical bone strains remained below the critical threshold (0.003) to prevent resorption. In the trabecular bone, only larger diameter/length configurations satisfied the previous strain criterion. In all simulations, trabecular bone stress remained below 3 MPa, whereas cortical bone stress peaked at 78 MPa. Notably, the implant model with the largest diameter/length minimized stress and strain concentrations in type II bone when compared to smaller designs, thereby demonstrating its biomechanical advantage.

1 January 2026 in Mechanics of Advanced Materials and Structures
Verified
Journal Article
Closed access
ARAmanda Robau-Porrua
Amanda Robau-Porrua
JRJesús González Ruíz
Jesús González Ruíz
APAlberto Picardo
Alberto Picardo
CPCarlos Navarro Pintado
Carlos Navarro Pintado
Ernesto J. Delgado-PujolErnesto J. Delgado-Pujol
Ernesto J. Delgado-Pujol
Yadir Torres HernándezYadir Torres Hernández
Yadir Torres Hernández

1 January 2020 in Matéria (Rio de Janeiro)
Verified
Journal Article
Open access
PDF file
ACAlejandro López Cruz
Alejandro López Cruz
ARAdrian Paz Ramos
Adrian Paz Ramos
LPLeonardo M. Pazos
Leonardo M. Pazos
MPMaría Belén Parodi
María Belén Parodi
Gabriel YbarraGabriel Ybarra
Gabriel Ybarra
JRJesús González Ruíz
Jesús González Ruíz
Chemical and physical methods have been generally used for modifying the surface of titanium implants with the aim of achieving better osseointegration. In this work, an evaluation of the effect of different chemicals and thermochemical treatments on the surface modification of titanium was carried out. Plates of commercially pure titanium were polished and treated with four different methods. Scanning electron microscopy, atomic force microscopy, energy-dispersive X-ray spectroscopy, infrared spectroscopy, X-ray diffraction and drop shape analysis were used to characterize the modified titanium surface. Our results showed that the AEPTTT surface exhibited the highest Ra values followed by AEAT, AEPT, polished Ti and AE samples. In addition, the AEAT and AEPTTT treatments developed the largest surface area, while the AE treatment produced the lowest surface area. Furthermore, the AEAT treatment created the most hydrophilic surface, which is known to positively affect the osseointegration rate of dental implants.

5 January 2017 in Materials Research
Verified
Journal Article
Open access
PDF file
JRJesús González Ruíz
Jesús González Ruíz
ACAlejandro Rodríguez Cristo
Alejandro Rodríguez Cristo
ARAdrian Paz Ramos
Adrian Paz Ramos
RPRafael Quintana Puchol
Rafael Quintana Puchol
The chromium carbide coatings are widely used in the mechanical industry due to its corrosion resistance and mechanical properties. In this work, we evaluated a new source of chromium and silicon with micro-additions of boron on the deposition of multi-component coatings of chromium carbides in W108 steel. The coatings were obtained by the pack cementation method, using a simultaneous deposition at 1000 oC for 4h. The coatings were analyzed by X-ray diffraction, X-ray energy dispersive spectroscopy, optical microscopy, microhardness test method and pin-on-disc wear test. It was found that the coatings formed on W108 steel were mainly constituted by (Cr,Fe)23C6, (Cr,Fe)7C3, Cr5-xSi3-xCx+z, Cr3B0,44C1,4 and (or) Cr7BC4. The carbide layers showed thicknesses between 14 and 15 µm and maximum values of microhardness between 15.8 and 18.8 GPa. Also, the micro-additions of boron to the mixtures showed statistically significant influence on the thickness, microhardness and abrasive wear resistance of the carbide coatings.

11 August 2025
Verified
Book Chapter
Closed access
PDF file
ARAmanda Robau-Porrua
Amanda Robau-Porrua
RARoberto Arancibia-Castillo
Roberto Arancibia-Castillo
JRJesús González Ruíz
Jesús González Ruíz
Yadir Torres HernándezYadir Torres Hernández
Yadir Torres Hernández

1 January 2024 in Revista Facultad de Ingeniería Universidad de Antioquia
Verified
Journal Article
Open access
PDF file
JCJuan Carlos Cruz-Pérez
Juan Carlos Cruz-Pérez
JRJesús González Ruíz
Jesús González Ruíz
LPLorenzo Perdomo-González
Lorenzo Perdomo-González
ACAmado Cruz-Crespo
Amado Cruz-Crespo
EAEduardo Peón Avés
Eduardo Peón Avés
RQRafael Quintana-Puchol
Rafael Quintana-Puchol
The use of feeding aids in the foundry process has become widespread globally recent decades, leading to increased efficiency. This article examines the characterization of rice husks, their ashes, and their positive impact as hot topping on the efficiency of open risers in casting cylindrical parts made of AISI 1045 steel. The rice husks were analyzed through X-Ray Diffraction test, Thermal-Gravimetric Analysis, and Differential Thermal-Gravimetric Analysis, while the ashes were characterized using X-Ray Diffraction. The analyzed rice husks were found to contain cellulose and low crystallinity silicon, whereas the ashes primarily consisted of cristobalite and tridymite. It was observed that the thermal decomposition of rice husks occurs in three stages, with approximately 81% of the mass lost during their combustion as hot topping on liquid steel. The location of cavities contraction in the risers of casting parts was made through longitudinal cut of the part-riser system. The increase in the rice husks topping layer thickness positively influences the concentration of these cavities on the upper surface and enhances the feeder's efficiency.