Eduardo Peón Avés

Dr. Eduardo Peón Avés

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Surface and Coatings Technology
Verified
Journal Article
Closed access
CDC. Domínguez-Trujillo
C. Domínguez-Trujillo
EAEduardo Peón Avés
Eduardo Peón Avés
ECERNESTO CHICARDI
ERNESTO CHICARDI
HPH. Pérez
H. Pérez
JRJosé Antonio Rodríguez-Ortiz
José Antonio Rodríguez-Ortiz
Yadir Torres HernándezYadir Torres Hernández
Yadir Torres Hernández

24 January 2017 in Materials
Verified
Journal Article
Open access
PDF file
AHAmir A. El Hadad
Amir A. El Hadad
EAEduardo Peón Avés
Eduardo Peón Avés
FGFederico R. García-Galvan
Federico R. García-Galvan
VBVioleta Barranco
Violeta Barranco
JPJuan Parra
Juan Parra
Juan Carlos GalvánJuan Carlos Galván
Juan Carlos Galván
The aim of this work was to prepare hydroxyapatite coatings (HAp) by a sol-gel method on Ti6Al4V alloy and to study the bioactivity, biocompatibility and corrosion protection behaviour of these coatings in presence of simulated body fluids (SBFs). Thermogravimetric/Differential Thermal Analyses (TG/DTA) and X-ray Diffraction (XRD) have been applied to obtain information about the phase transformations, mass loss, identification of the phases developed, crystallite size and degree of crystallinity of the obtained HAp powders. Fourier Transformer Infrared Spectroscopy (FTIR) has been utilized for studying the functional groups of the prepared structures. The surface morphology of the resulting HAp coatings was studied by Scanning Electron Microscopy (SEM). The bioactivity was evaluated by soaking the HAp-coatings/Ti6Al4V system in Kokubo’s Simulated Body Fluid (SBF) applying Inductively Coupled Plasma (ICP) spectrometry. 3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyl tetrazolium bromide (MTT) and Alamar blue cell viability assays were used to study the biocompatibility. Finally, the corrosion behaviour of HAp-coatings/Ti6Al4V system was researched by means of Electrochemical Impedance Spectroscopy (EIS). The obtained results showed that the prepared powders were nanocrystalline HAp with little deviations from that present in the human bone. All the prepared HAp coatings deposited on Ti6Al4V showed well-behaved biocompatibility, good bioactivity and corrosion protection properties.

1 August 2018 in Surface and Coatings Technology
Verified
Journal Article
Closed access
Yadir Torres HernándezYadir Torres Hernández
Yadir Torres Hernández
PSPerla Sarria
Perla Sarria
FGFrancisco J. Gotor
Francisco J. Gotor
EGEliel Gutiérrez
Eliel Gutiérrez
EAEduardo Peón Avés
Eduardo Peón Avés
JGJesús E. González
Jesús E. González

25 April 2014 in Journal of Materials Chemistry B
Verified
Journal Article
Open access
PDF file
AHA. A. El Hadad
A. A. El Hadad
VBV. Barranco
V. Barranco
AJAntonia Jimenez-Morales
Antonia Jimenez-Morales
EAEduardo Peón Avés
Eduardo Peón Avés
GHG. J. Hickman
G. J. Hickman
Juan Carlos GalvánJuan Carlos Galván
Juan Carlos Galván
Application of novel organic–inorganic hybrid sol–gel coatings containing dispersed hydroxyapatite particles improved the biocompatibility and corrosion protection properties of the Ti6Al4V alloy used in medical implants.

11 February 2021 in Metals
Verified
Journal Article
Open access
PDF file
JRJesús E. González Ruíz
Jesús E. González Ruíz
GOGabriela De Armas Ortiz
Gabriela De Armas Ortiz
JNJeidy Negrin
Jeidy Negrin
Ana M. BeltranAna M. Beltran
Ana M. Beltran
PTPaloma Trueba
Paloma Trueba
Yadir Torres HernándezYadir Torres Hernández
Yadir Torres Hernández
Ti6Al4V samples, obtained by selective laser melting (SLM), were subjected to successive treatments: acid etching, chemical oxidation in hydrogen peroxide solution and thermochemical processing. The effect of temperature and time of acid etching on the surface roughness, morphology, topography and chemical and phase composition after the thermochemical treatment was studied. The surfaces were characterized by scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction and contact profilometry. The temperature used in the acid etching had a greater influence on the surface features of the samples than the time. Acid etching provided the original SLM surface with a new topography prior to oxidation and thermochemical treatments. A nanostructure was observed on the surfaces after the full process, both on their protrusions and pores previously formed during the acid etching. After the thermochemical treatment, the samples etched at 40 °C showed macrostructures with additional submicro and nanoscale topographies. When a temperature of 80 °C was used, the presence of micropores and a thicker anatase layer, detectable by X-ray diffraction, were also observed. These surfaces are expected to generate greater levels of bioactivity and high biomechanics fixation of implants as well as better resistance to fatigue.

18 December 2008 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Closed access
PDF file
EAEduardo Peón Avés
Eduardo Peón Avés
Gastón FuentesGastón Fuentes
Gastón Fuentes
MSMarcia Soares Sader
Marcia Soares Sader
Juan Carlos GalvánJuan Carlos Galván
Juan Carlos Galván
JYJulio C. Llópiz Yurell
Julio C. Llópiz Yurell
GSGloria D. Almeida Soares
Gloria D. Almeida Soares