Parisa Esmaili

Dr. Parisa Esmaili

Department of Electronics, Information and Bioengineering Politecnico di Milano Milan, Italy
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Parisa EsmailiParisa Esmaili
Parisa Esmaili
FCFederico Cavedo
Federico Cavedo
Michele NorgiaMichele Norgia
Michele Norgia

3 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
FCFederico Cavedo
Federico Cavedo
Parisa EsmailiParisa Esmaili
Parisa Esmaili
Michele NorgiaMichele Norgia
Michele Norgia
Optical rangefinders based on Self-Mixing Interferometry are widely described in literature, but not yet on the market as commercial instruments. The main reason is that it is relatively easy to propose new elaboration techniques and get results in controlled conditions, while it is very difficult to develop a reliable instrument. In this paper, we propose a laser distance sensor with improved reliability, realized through a wavelength modulation at a different frequency, able to decorrelate single measurement errors and obtain improvement by averages. A dedicated software is implemented to automatically calculate the modulation pre-emphasis, needed to linearize the wavelength modulation. Finally, data selection algorithms allow to overcome signal fading problems due to the speckle effect. A prototype demonstrates the approach with about 0.1 mm accuracy up to 2 m of distance at 200 measurements per second.

31 October 2025 in Journal of Manufacturing Systems
Verified
Journal Article
Open access
MZMohsen Zeynivand
Mohsen Zeynivand
Parisa EsmailiParisa Esmaili
Parisa Esmaili
LCLoredana Cristaldi
Loredana Cristaldi
giambattista gruossogiambattista gruosso
giambattista gruosso

19 June 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
Parisa EsmailiParisa Esmaili
Parisa Esmaili
Michele NorgiaMichele Norgia
Michele Norgia
SDsilvano - donati
silvano - donati
In a Self-Mixing Interferometer built around a laser diode, the signals at the outputs of the two mirrors are in phase opposition, whereas noise fluctuations are partially correlated. Thus, on making the difference between the two outputs, the useful signal is doubled in amplitude and the Signal-to-Noise ratio is even more enhanced. Through a second-quantization model the improvement is theoretically predicted to be dependent on laser facets reflectivity. The results are then validated by experimental measurements with different laser types, that show very good agreement with theoretical results. The new technique is applicable to a number of already existent self-mixing sensors, potentially improving significantly their measurement performances.

22 April 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Parisa EsmailiParisa Esmaili
Parisa Esmaili
FCFederico Cavedo
Federico Cavedo
Michele NorgiaMichele Norgia
Michele Norgia
The presence of liquid slightly changes the local properties of submerged transmission line. A dedicated sensor is presented in this paper to estimate the level of liquid, through two different determinations: measurement of the overall capacitance of a bi-wires and time of flight estimation of electromagnetic radiation. Since two measurement methods are physically independent, the proposed sensor has an intrinsic redundancy. The level of liquid is measured through phase shift: the signals are sampled at a sufficiently high frequency and then phase differences is evaluated by calculating the coefficients of the digital Fourier transform. Both measurements are performed directly in baseband without requiring frequency conversions. In contrast with typical TDR system where the end of the cable is open or short-circuited, the bi-wires fold and return to the measurement electronics. The characterization of the proposed sensor is determined experimentally for water and diesel fuel, in good agreement with simulation results. As results show, both phase-shifting measurements are linear with the liquid level, providing a resolution in the order of 0.1 mm through a compact and low-cost realization.

24 June 2024 in IEEE Sensors Letters
Verified
Journal Article
Open access
Parisa EsmailiParisa Esmaili
Parisa Esmaili
LCLoredana Cristaldi
Loredana Cristaldi
Evaluating the quality of the machining process annotated by experts on the floor in case of developing a silent anomaly is a challenging task. Components wear, wrongly labeled processes or highly imbalanced data are some examples of real-world difficulties that may prevent the reliability of Machine Learning (ML) algorithms in the manufacturing environment. Since human experts may face several challenges while annotating such high-frequency data, this paper evaluates effective health indexes using time-frequency analysis to extract reliable patterns or vibration signatures assigned to the process quality or bearing health status. A benchmark dataset for process monitoring of brownfield milling machines over two years is utilized in this paper where the resulting process is evaluated by experts in a gauging station. Vibration signals are collected from 3 different Computer Numerical Control (CNC) using a triaxial accelerometer which is mounted on the rear side of the machines. Considering a single operation, the extracted vibration signature is validated on two test CNC machines. As results show, the overall energy level in the frequency range of 01 kHz while considering only radial axes gives effective insight into the quality of the process and degradation pattern.