Federico Cavedo

Mr. Federico Cavedo

Politecnico di MIlano
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Parisa EsmailiParisa Esmaili
Parisa Esmaili
FCFederico Cavedo
Federico Cavedo
Michele NorgiaMichele Norgia
Michele Norgia

3 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
FCFederico Cavedo
Federico Cavedo
Parisa EsmailiParisa Esmaili
Parisa Esmaili
Michele NorgiaMichele Norgia
Michele Norgia
Optical rangefinders based on Self-Mixing Interferometry are widely described in literature, but not yet on the market as commercial instruments. The main reason is that it is relatively easy to propose new elaboration techniques and get results in controlled conditions, while it is very difficult to develop a reliable instrument. In this paper, we propose a laser distance sensor with improved reliability, realized through a wavelength modulation at a different frequency, able to decorrelate single measurement errors and obtain improvement by averages. A dedicated software is implemented to automatically calculate the modulation pre-emphasis, needed to linearize the wavelength modulation. Finally, data selection algorithms allow to overcome signal fading problems due to the speckle effect. A prototype demonstrates the approach with about 0.1 mm accuracy up to 2 m of distance at 200 measurements per second.

22 April 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Parisa EsmailiParisa Esmaili
Parisa Esmaili
FCFederico Cavedo
Federico Cavedo
Michele NorgiaMichele Norgia
Michele Norgia
The presence of liquid slightly changes the local properties of submerged transmission line. A dedicated sensor is presented in this paper to estimate the level of liquid, through two different determinations: measurement of the overall capacitance of a bi-wires and time of flight estimation of electromagnetic radiation. Since two measurement methods are physically independent, the proposed sensor has an intrinsic redundancy. The level of liquid is measured through phase shift: the signals are sampled at a sufficiently high frequency and then phase differences is evaluated by calculating the coefficients of the digital Fourier transform. Both measurements are performed directly in baseband without requiring frequency conversions. In contrast with typical TDR system where the end of the cable is open or short-circuited, the bi-wires fold and return to the measurement electronics. The characterization of the proposed sensor is determined experimentally for water and diesel fuel, in good agreement with simulation results. As results show, both phase-shifting measurements are linear with the liquid level, providing a resolution in the order of 0.1 mm through a compact and low-cost realization.

1 July 2025 in Metrology
Verified
Journal Article
Open access
PDF file
Parisa EsmailiParisa Esmaili
Parisa Esmaili
FCFederico Cavedo
Federico Cavedo
Michele NorgiaMichele Norgia
Michele Norgia
Slight changes in the local properties of a transmission line, dipped in a liquid, can be used to estimate its level through two different determination techniques, involving the capacitance and electromagnetic wave speed, measured by the time of flight. Indeed, the overall capacitance of a transmission line varies linearly with the liquid level, as well as the time of flight of the electromagnetic wave. Both quantities can be estimated via the measurement of a phase shift at radio frequencies, and the simultaneous measurements can be realized using a compact and low-cost design working at a few megahertz. This paper presents a further improvement in sensitivity to challenge the performance of this kind of level sensor, dealing with liquids with low dielectric constants. To better describe this effect, a study on the overall capacitance of different transmission path segments was conducted in COMSOL Multiphysics. The level measurement was performed experimentally on the realized prototype while considering the measured phase shift as a function of the liquid level, for both an unshielded twisted-pair and magnet wires. As the results showed, with the magnet wires the sensitivity was improved by a factor of about 4, consistently aligning with the simulation results and providing a predictable phase shift response with increasing liquid levels. Consequently, magnet wire is a good choice for precise level measurements through RF phase shifts, especially in the case of low relative permittivity liquids.

11 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
FCFederico Cavedo
Federico Cavedo
Parisa EsmailiParisa Esmaili
Parisa Esmaili
Michele NorgiaMichele Norgia
Michele Norgia
A low-cost optical reflectivity sensor is proposed in this paper, able to detect the presence of objects or surface optical properties variations, at a distance of up to 20 m. A collimated laser beam is pulsed at 10 kHz, and a synchronous digital detector coherently measures the back-diffused light collected through a 1-inch biconvex lens. The sensor is a cost-effective solution for punctual measurement of the surface reflection at different distances. To enhance the interference immunity, an algorithm based on a double-side digital baseline restorer is proposed and implemented to accurately detect the amplitude of the reflected light. As results show, the sensor is robust against ambient light and shows a strong sensitivity on a wide reflection range. The capability of the proposed sensor was evaluated experimentally for object detection and recognition, in addition to dedicated measurement systems, like remote encoders or keyphasors, realized far from the object to be measured.

8 March 2024 in Metrology
Verified
Journal Article
Open access
PDF file
FCFederico Cavedo
Federico Cavedo
Parisa EsmailiParisa Esmaili
Parisa Esmaili
Michele NorgiaMichele Norgia
Michele Norgia
Frequency estimation is often the basis of various measurement techniques, among which optical distance measurement stands out. One of the most used techniques is interpolated fast Fourier transform due to its simplicity, combined with good performance. In this work, we study the limits of this technique in the case of real signals, with reference to a particular interferometric technique known as self-mixing interferometry. The aim of this research is the better understanding of frequency estimation performances in real applications, together with guidance on how to improve them in specific optical measurement techniques. An optical rangefinder, based on self-mixing interferometry, has been realized and characterized. The simulation results allow us to explain the limits of the interpolated fast Fourier transform applied to the realized instrument. Finally, a method for overcoming them is proposed by decorrelating the errors between the measurements, which can provide a guideline for the design of frequency-modulated interferometric distance meters.