Hiba Omer

Dr. Hiba Omer

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Saudi Journal of Biological Sciences
Verified
Journal Article
Open access
HOHiba Omer
Hiba Omer
Radiation is used in medicine to diagnose and treat diseases but it can also cause harm to the body by burning or mutation. This depends on whether the radiation is ionizing or nonionizing. Despite its vast applications in surgery, dermatology and cosmetics, little is taught and thus known about non-ionizing radiation.

1 January 2021 in Saudi Journal of Biological Sciences
Verified
Journal Article
Open access
HOHiba Omer
Hiba Omer
SASuhaib Alameen
Suhaib Alameen
WMWaleed E. Mahmoud
Waleed E. Mahmoud
ASAbdelmoneim Sulieman
Abdelmoneim Sulieman
ONOmaima Nasir
Omaima Nasir
FAFouad Abolaban
Fouad Abolaban
This study aims to estimate the effective radiation dose and organ dose from head CT procedures. It was conducted in three main private hospitals in Khartoum State-Sudan, using Toshiba machines with 64 slices. The total number of patients included in this study was 142 patients (82 males and 60 females). The effective dose and organ dose were calculated by CT Expo software. The effective dose slightly varied among patients according to gender and age. The effective dose for female patients (5.99 mSv) was higher than that for male patients (5.84 mSv), and the pediatric dose (5.46 mSv) was lower than the adults’ dose (5.94 mSv).

2 June 2022 in Saudi Journal of Biological Sciences
Verified
Journal Article
Open access
Thanh Tai DuongThanh Tai Duong
Thanh Tai Duong
LOLuong Thi Oanh
Luong Thi Oanh
PPPham Hoai Phuong
Pham Hoai Phuong
ASAbdelmoneim Sulieman
Abdelmoneim Sulieman
FAFouad Abolaban
Fouad Abolaban
James C. L. ChowJames C. L. Chow
James C. L. Chow
Dosimetric and radiobiological evaluations for the Jaws-only Intensity-modulated radiotherapy (JO-IMRT) technique for head and neck jaws-only intensity-modulated radiation therapy (JO-IMRT) and 3D conformal radiation therapy (3D-CRT). To compare the head-and-neck therapeutic approaches utilizing JO-IMRT and 3D-CRT techniques, different radiation dose indices were calculated, including: conformity index (CI), homogeneity index (HI), and radiobiological variables like Niemierko's equivalent uniform dose based tumor control probability (TCP) of planning target volume (PTV), normal tissue complication probability (NTCP) of organs at risk (OAR) (brainstem, spinal cord, and parotid grand). Twenty-five nasopharynx patients were studied using the Prowess Panther Treatment Planning System (Prowess Inc). The results were compared with the dose distribution obtained using 3D-CRT. Regarding tumor coverage and CI, JO-IMRT showed better results than 3D-CRT. The average doses received by the PTVs were quite similar: 72.1 ± 0.8 Gy by 3D-CRT and 72.5 ± 0.6 Gy by JO-IMRT plans (p > 0.05). The mean doses received by the parotid gland were 56.7 ± 0.7 Gy by 3D-CRT and 26.8 ± 0.3 Gy by JO-IMRT (p > 0.05). The HI and CI were 0.13 ± 0.01 and 0.14 ± 0.05 and (p > 0.05) by 3D-CRT and 0.83 ± 0.05 and 0.73 ± 0.10 by JO-IMRT (p < 0.05). The average TCP of PTV was 0.82 ± 0.08 by 3D-CRT and 0.92 ± 0.02 by JO-IMRT. Moreover, the NTCP of the parotid glands, brain stem, and spinal cord were lower using the JO-IMRT than 3D-CRT plans. In comparison to the 3D-CRT approach, the JO-IMRT technique was able to boost dose coverage to the PTV, improve the target's CI and HI, and spare the parotid glands. This suggests the power of the JO-IMRT over 3D-CRT in head-and-neck radiotherapy.

7 June 2022 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
AAAbdullah Almujally
Abdullah Almujally
NTNissren Tamam
Nissren Tamam
ASAbdelmoneim Sulieman
Abdelmoneim Sulieman
DTDuong Thanh Tai
Duong Thanh Tai
HOHiba Omer
Hiba Omer
DBDAVID BRADLEY
DAVID BRADLEY

1 April 2021 in Saudi Journal of Biological Sciences
Verified
Journal Article
Open access
BEButhayna G. Elshaikh
Buthayna G. Elshaikh
MGMem Garelnabi
Mem Garelnabi
HOHiba Omer
Hiba Omer
ASAbdelmoneim Sulieman
Abdelmoneim Sulieman
BHB. Habeeballa
B. Habeeballa
RTRania A. Tabeidi
Rania A. Tabeidi
Brain neoplasms or intracranial tumors, which are more common in older adults, can affect individuals of any age including pediatric and children. Exposure to carcinogenic agents including ionizing radiation and family history is one of the main causes of the disease. Early diagnosis is crucial to avoid prolonged. patients' suffering. The aim of the study was to efficiently recognize the brain tumors from the other brain tissues which include grey and white matter as well as cerebrospinal fluid (CSF). This study was performed using axial, sagittal and coronal views for fifty brain tumor patients randomly selected from a set of 200 patients, with a “control” set consisting of images showing no sign of disease; and the “test” brain MRI images for patients diagnosed with brain tumor. The study includes both genders with age ranging from 18 years to 83 years old, (56.5 ± 17.2). The brain images were acquired using a standard head coil Philips Intera 1.5 Tesla machine (USA). The thickness of each section in the entire sequence was 8 mm. Acquisition of T2-weighted and T1-weighted were performed. Interactive Data Language software was used to analyze the data. The results of this study showed that: the overall accuracy of classification process was 94.8%, and for the tumor; the sensitivity was 97.3%. White matter and grey matter showed a classification accuracy of 95.7% and 89.7% and for CSF the accuracy was 94.3%. The results showed that brain tumor can be classified successfully and delineated using texture analysis with minimum efforts and with high accuracy for brain tumors.

25 May 2023 in Electronics
Verified
Journal Article
Open access
PDF file
Nghia Thanh NguyenNghia Thanh Nguyen
Nghia Thanh Nguyen
Thanh Tai DuongThanh Tai Duong
Thanh Tai Duong
HOHiba Omer
Hiba Omer
ASAbdelmoneim Sulieman
Abdelmoneim Sulieman
DBDAVID BRADLEY
DAVID BRADLEY
An accurate and compact electrocardiogram (ECG) device will greatly assist doctors in diagnosing heart diseases. It will also help to address the increasing number of deaths caused by heart disease. Accordingly, the goal of the project is to design and construct an easy-to-use compact 12-lead electrocardiogram device that communicates with a computer to create a system that can continuously monitor heart rate and which can be connected to allied medical systems. The design is based on an ECG receiver circuit utilizing an IC ADS1293 and an Arduino Nano. The ADS1293 has built-in input Electromagnetic Interference (EMI) filters, quantizers, and digital filters, which help in reducing the size of the device. The software has been created using the C# programming language, with Windows Presentation Foundation (WPF), aiding the collection of the ECG signals from the receiving circuit via the computer port. An ECG Multiparameter Simulator has been used to calibrate the ECG device. Finally, a plan has been developed to connect the arrangement to health systems according to HL7 FHIR (Health Level Seven Fast Healthcare Interoperability Resources) through Representational State Transfer Application Programming Interface (Rest API). The ECG device, completed at the cost of U$169 excluding labor, allows for the signal of 12 leads of ECG signal to be obtained from 10 electrodes mounted on the body. The processed ECG data was written to a JSON file with a maximum recording time of up to three days, managed by a Structured Query Language Server (SQL) Server database. The software retrieves patient data from electrical medical records in accordance with HL7 FHIR standards. A compact and easy-to-use ECG device was successfully designed to record ECG signals. An in-house developed software was also completed to display and store the ECG signals.