Thanh Tai Duong

Dr. Thanh Tai Duong

Western University, London, Ontario, Canada
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2022 in Saudi Journal of Biological Sciences
Verified
Journal Article
Open access
Thanh Tai DuongThanh Tai Duong
Thanh Tai Duong
LOLuong Thi Oanh
Luong Thi Oanh
PPPham Hoai Phuong
Pham Hoai Phuong
ASAbdelmoneim Sulieman
Abdelmoneim Sulieman
FAFouad Abolaban
Fouad Abolaban
James C. L. ChowJames C. L. Chow
James C. L. Chow
Dosimetric and radiobiological evaluations for the Jaws-only Intensity-modulated radiotherapy (JO-IMRT) technique for head and neck jaws-only intensity-modulated radiation therapy (JO-IMRT) and 3D conformal radiation therapy (3D-CRT). To compare the head-and-neck therapeutic approaches utilizing JO-IMRT and 3D-CRT techniques, different radiation dose indices were calculated, including: conformity index (CI), homogeneity index (HI), and radiobiological variables like Niemierko's equivalent uniform dose based tumor control probability (TCP) of planning target volume (PTV), normal tissue complication probability (NTCP) of organs at risk (OAR) (brainstem, spinal cord, and parotid grand). Twenty-five nasopharynx patients were studied using the Prowess Panther Treatment Planning System (Prowess Inc). The results were compared with the dose distribution obtained using 3D-CRT. Regarding tumor coverage and CI, JO-IMRT showed better results than 3D-CRT. The average doses received by the PTVs were quite similar: 72.1 ± 0.8 Gy by 3D-CRT and 72.5 ± 0.6 Gy by JO-IMRT plans (p > 0.05). The mean doses received by the parotid gland were 56.7 ± 0.7 Gy by 3D-CRT and 26.8 ± 0.3 Gy by JO-IMRT (p > 0.05). The HI and CI were 0.13 ± 0.01 and 0.14 ± 0.05 and (p > 0.05) by 3D-CRT and 0.83 ± 0.05 and 0.73 ± 0.10 by JO-IMRT (p < 0.05). The average TCP of PTV was 0.82 ± 0.08 by 3D-CRT and 0.92 ± 0.02 by JO-IMRT. Moreover, the NTCP of the parotid glands, brain stem, and spinal cord were lower using the JO-IMRT than 3D-CRT plans. In comparison to the 3D-CRT approach, the JO-IMRT technique was able to boost dose coverage to the PTV, improve the target's CI and HI, and spare the parotid glands. This suggests the power of the JO-IMRT over 3D-CRT in head-and-neck radiotherapy.

26 September 2023 in Frontiers in Oncology
Verified
Journal Article
Open access
Thanh Tai DuongThanh Tai Duong
Thanh Tai Duong
LPLuong Tien Phat
Luong Tien Phat
NNNgoc Anh Nguyen
Ngoc Anh Nguyen
HSHuynh Van Tran Sang
Huynh Van Tran Sang
TLTran Minh Loc
Tran Minh Loc
JCJames C. L. Chow
James C. L. Chow
Purpose: The objective of this research is to compare the efficacy of conventional and hypofractionated radiotherapy treatment plans for breast cancer patients, with a specific focus on the unique features of the Halcyon system.Methods and materials: The study collected and analyzed dose volume histogram (DVH) data for two groups of treatment plans implemented using the Halcyon system. The first group consisted of 19 patients who received conventional fractionated (CF) treatment with a total dose of 50 Gy in 25 fractions, while the second group comprised 9 patients who received hypofractionated (HF) treatment with a total dose of 42.56 Gy in 16 fractions. The DVH data was used to calculate various parameters, including tumor control probability (TCP), normal tissue complication probability (NTCP), and equivalent uniform dose (EUD), using radiobiological models.Results: The results indicated that the CF plan resulted in higher TCP but lower NTCP for the lungs compared to the HF plan. The EUD for the HF plan was approximately 49 Gy (114% of its total dose) while that for the CF plan was around 53 Gy (107% of its total dose).Conclusions: The analysis suggests that while the CF plan is better at controlling tumors, it is not as effective as the HF plan in minimizing side effects. Additionally, it is suggested that there may be an optimal configuration for the HF plan that can provide the same or higher EUD than the CF plan.

1 January 2019 in Reports of Practical Oncology and Radiotherapy
Verified
Journal Article
Closed access
Thanh Tai DuongThanh Tai Duong
Thanh Tai Duong
LOLuong Thi Oanh
Luong Thi Oanh
NSNguyen Dong Son
Nguyen Dong Son
TLTruong Thi Hong Loan
Truong Thi Hong Loan
JCJames C.L. Chow
James C.L. Chow
The aim of this study is to verify the Prowess Panther jaws-only intensity modulated radiation therapy (JO-IMRT) treatment planning (TP) by comparing the TP dose distributions for head-and-neck (H&N) cancer with the ones simulated by Monte Carlo (MC). To date, dose distributions planned using JO-IMRT for H&N patients were found superior to the corresponding three-dimensional conformal radiotherapy (3D-CRT) plans. Dosimetry of the JO-IMRT plans were also experimentally verified using an ionization chamber, MapCHECK 2, and Octavius 4D and good agreements were shown. Dose distributions of 15 JO-IMRT plans of nasopharyngeal patients were recalculated using the EGSnrc Monte Carlo code. The clinical photon beams were simulated using the BEAMnrc. The absorbed dose to patients treated by fixed-field IMRT was computed using the DOSXYZnrc. The simulated dose distributions were then compared with the ones calculated by the Collapsed Cone Convolution (CCC) algorithm on the TPS, using the relative dose error comparison and the gamma index using global methods implemented in PTW-VeriSoft with 3%/3 mm, 2%/2 mm, 1%/1 mm criteria. There is a good agreement between the MC and TPS dose. The average gamma passing rates were 93.3 ± 3.1%, 92.8 ± 3.2%, 92.4 ± 3.4% based on the 3%/3 mm, 2%/2 mm, 1%/1 mm criteria, respectively. According to the results, it is concluded that the CCC algorithm was adequate for most of the IMRT H&N cases where the target was not immediately adjacent to the critical structures.

15 March 2023 in Journal of Radiation Research and Applied Sciences
Verified
Journal Article
Open access
HHHoang Thanh-Phi Hung
Hoang Thanh-Phi Hung
PTPham Nhu Tuyen
Pham Nhu Tuyen
Thanh Tai DuongThanh Tai Duong
Thanh Tai Duong
HLHa Quoc Long
Ha Quoc Long
ASAbdelmoneim Sulieman
Abdelmoneim Sulieman
TLTing-Yim Lee
Ting-Yim Lee

1 June 2017 in Physica Medica
Verified
Journal Article
Closed access
Thanh Tai DuongThanh Tai Duong
Thanh Tai Duong
NSNguyen Dong Son
Nguyen Dong Son
TLTruong Thi Hong Loan
Truong Thi Hong Loan
HAH.P.W Anson
H.P.W Anson

25 May 2023 in Electronics
Verified
Journal Article
Open access
PDF file
Nghia Thanh NguyenNghia Thanh Nguyen
Nghia Thanh Nguyen
Thanh Tai DuongThanh Tai Duong
Thanh Tai Duong
HOHiba Omer
Hiba Omer
ASAbdelmoneim Sulieman
Abdelmoneim Sulieman
DBDAVID BRADLEY
DAVID BRADLEY
An accurate and compact electrocardiogram (ECG) device will greatly assist doctors in diagnosing heart diseases. It will also help to address the increasing number of deaths caused by heart disease. Accordingly, the goal of the project is to design and construct an easy-to-use compact 12-lead electrocardiogram device that communicates with a computer to create a system that can continuously monitor heart rate and which can be connected to allied medical systems. The design is based on an ECG receiver circuit utilizing an IC ADS1293 and an Arduino Nano. The ADS1293 has built-in input Electromagnetic Interference (EMI) filters, quantizers, and digital filters, which help in reducing the size of the device. The software has been created using the C# programming language, with Windows Presentation Foundation (WPF), aiding the collection of the ECG signals from the receiving circuit via the computer port. An ECG Multiparameter Simulator has been used to calibrate the ECG device. Finally, a plan has been developed to connect the arrangement to health systems according to HL7 FHIR (Health Level Seven Fast Healthcare Interoperability Resources) through Representational State Transfer Application Programming Interface (Rest API). The ECG device, completed at the cost of U$169 excluding labor, allows for the signal of 12 leads of ECG signal to be obtained from 10 electrodes mounted on the body. The processed ECG data was written to a JSON file with a maximum recording time of up to three days, managed by a Structured Query Language Server (SQL) Server database. The software retrieves patient data from electrical medical records in accordance with HL7 FHIR standards. A compact and easy-to-use ECG device was successfully designed to record ECG signals. An in-house developed software was also completed to display and store the ECG signals.