Jose Rodriguez-Delgado

Dr. Jose Rodriguez-Delgado

Tec de Monterrey, Campus Monterrey
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Open access
MRMelissa M. Rodríguez-Delgado
Melissa M. Rodríguez-Delgado
GAGibrán S. Alemán-Nava
Gibrán S. Alemán-Nava
JRJose Rodriguez-Delgado
Jose Rodriguez-Delgado
GDGraciano Dieck-Assad
Graciano Dieck-Assad
SMSergio O. Martínez-Chapa
Sergio O. Martínez-Chapa
VSVictor Roberto Parra Sanchez
Victor Roberto Parra Sanchez
Monitoring of phenolic compounds in the food industry and for environmental and medical applications has become more relevant in recent years. Conventional methods for detection and quantification of these compounds, such as spectrophotometry and chromatography, are time consuming and expensive. However, laccase biosensors represent a fast method for on-line and in situ monitoring of these compounds. We discuss the main transduction principles. We divide the electrochemical principle into amperometric, voltammetric, potentiometric and conductometric sensors. We divide optical transducers into fluorescence and absorption. The amperometric transducer method is the most widely studied and used for laccase biosensors. Optical biosensors present higher sensitivity than the other biosensors. Laccase production is dominated by a few fungus genera: Trametes, Aspergillus, and Ganoderma. We present an overview of laccase biosensors used for the determination of phenolic compounds in industrial applications

13 January 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
DRDenise Rivera
Denise Rivera
GQGabriela Elizabeth Quintanilla-Villanueva
Gabriela Elizabeth Quintanilla-Villanueva
DMDonato Luna Moreno
Donato Luna Moreno
AAARACELI SÁNCHEZ ALVAREZ
ARACELI SÁNCHEZ ALVAREZ
JRJose Rodriguez-Delgado
Jose Rodriguez-Delgado
MRMelissa Rodríguez-Delgado
Melissa Rodríguez-Delgado
Plastic pollution, particularly from microplastics (MPs) and nanoplastics (NPs), has become a critical environmental and health concern due to their widespread distribution, persistence, and potential toxicity. MPs and NPs originate from primary sources, such as cosmetic microspheres or synthetic fibers, and secondary fragmentation of larger plastics through environmental degradation. These particles, typically less than 5 mm, are found globally, from deep seabeds to human tissues, and are known to adsorb and release harmful pollutants, exacerbating ecological and health risks. Effective detection and quantification of MPs and NPs are essential for understanding and mitigating their impacts. Current analytical methods include physical and chemical techniques. Physical methods, such as optical and electron microscopy, provide morphological details but often lack specificity and are time-intensive. Chemical analyses, such as Fourier transform infrared (FTIR) and Raman spectroscopy, offer molecular specificity but face challenges with smaller particle sizes and complex matrices. Thermal analytical methods, including pyrolysis gas chromatography–mass spectrometry (Py-GC-MS), provide compositional insights but are destructive and limited in morphological analysis. Emerging (bio)sensing technologies show promise in addressing these challenges. Electrochemical biosensors offer cost-effective, portable, and sensitive platforms, leveraging principles such as voltammetry and impedance to detect MPs and their adsorbed pollutants. Plasmonic techniques, including surface plasmon resonance (SPR) and surface-enhanced Raman spectroscopy (SERS), provide high sensitivity and specificity through nanostructure-enhanced detection. Fluorescent biosensors utilizing microbial or enzymatic elements enable the real-time monitoring of plastic degradation products, such as terephthalic acid from polyethylene terephthalate (PET). Advancements in these innovative approaches pave the way for more accurate, scalable, and environmentally compatible detection solutions, contributing to improved monitoring and remediation strategies. This review highlights the potential of biosensors as advanced analytical methods, including a section on prospects that address the challenges that could lead to significant advancements in environmental monitoring, highlighting the necessity of testing the new sensing developments under real conditions (composition/matrix of the samples), which are often overlooked, as well as the study of peptides as a novel recognition element in microplastic sensing.

1 June 2020 in Dyes and Pigments
Verified
Journal Article
Open access
PHPatricia Hernández-Velasco
Patricia Hernández-Velasco
IMIrene Morales-Atilano
Irene Morales-Atilano
MRMelissa Rodríguez-Delgado
Melissa Rodríguez-Delgado
JRJose Rodriguez-Delgado
Jose Rodriguez-Delgado
DLDonato Luna-Moreno
Donato Luna-Moreno
Juan Francisco Villarreal-ChiuJuan Francisco Villarreal-Chiu
Juan Francisco Villarreal-Chiu

5 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
GQGabriela Elizabeth Quintanilla-Villanueva
Gabriela Elizabeth Quintanilla-Villanueva
JVJesus Maldonado Vazquez
Jesus Maldonado Vazquez
DMDonato Luna Moreno
Donato Luna Moreno
JRJose Rodriguez-Delgado
Jose Rodriguez-Delgado
Juan Francisco Villarreal-ChiuJuan Francisco Villarreal-Chiu
Juan Francisco Villarreal-Chiu
MRMelissa Rodríguez-Delgado
Melissa Rodríguez-Delgado
Aquaculture is an expanding economic sector that nourishes the world’s growing population due to its nutritional significance over the years as a source of high-quality proteins. However, it has faced severe challenges due to significant cases of environmental pollution, pathogen outbreaks, and the lack of traceability that guarantees the quality assurance of its products. Such context has prompted many researchers to work on the development of novel, affordable, and reliable technologies, many based on nanophotonic sensing methodologies. These emerging technologies, such as surface plasmon resonance (SPR), localised SPR (LSPR), and fibre-optic SPR (FO-SPR) systems, overcome many of the drawbacks of conventional analytical tools in terms of portability, reagent and solvent use, and the simplicity of sample pre-treatments, which would benefit a more sustainable and profitable aquaculture. To highlight the current progress made in these technologies that would allow them to be transferred for implementation in the field, along with the lag with respect to the most cutting-edge plasmonic sensing, this review provides a variety of information on recent advances in these emerging methodologies that can be used to comprehensively monitor the various operations involving the different commercial stages of farmed aquaculture. For example, to detect environmental hazards, track fish health through biochemical indicators, and monitor disease and biosecurity of fish meat products. Furthermore, it highlights the critical issues associated with these technologies, how to integrate them into farming facilities, and the challenges and prospects of developing plasmonic-based sensors for aquaculture.

9 February 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
GQGabriela Elizabeth Quintanilla-Villanueva
Gabriela Elizabeth Quintanilla-Villanueva
DMDonato Luna Moreno
Donato Luna Moreno
EBEdgar Allan Blanco
Edgar Allan Blanco
JRJose Rodriguez-Delgado
Jose Rodriguez-Delgado
Juan Francisco Villarreal-ChiuJuan Francisco Villarreal-Chiu
Juan Francisco Villarreal-Chiu
MRMelissa Rodríguez-Delgado
Melissa Rodríguez-Delgado
Chlorophene is an important antimicrobial agent present in disinfectant products which has been related to health and environmental effects, and its detection has been limited to chromatographic techniques. Thus, there is a lack of research that attempts to develop new analytical tools, such as biosensors, that address the detection of this emerging pollutant. Therefore, a new biosensor for the direct detection of chlorophene in real water is presented, based on surface plasmon resonance (SPR) and using a laccase enzyme as a recognition element. The biosensor chip was obtained by covalent immobilization of the laccase on a gold-coated surface through carbodiimide esters. The analytical parameters accomplished resulted in a limit of detection and quantification of 0.33 mg/L and 1.10 mg/L, respectively, fulfilling the concentrations that have already been detected in environmental samples. During the natural river’s measurements, no significant matrix effects were observed, obtaining a recovery percentage of 109.21% ± 7.08, which suggested that the method was suitable for the fast and straightforward analysis of this contaminant. Finally, the SPR measurements were validated with an HPLC method, which demonstrated no significant difference in terms of precision and accuracy, leading to the conclusion that the biosensor reflects its potential as an alternative analytical tool for the monitoring of chlorophene in aquatic environments.

1 October 2016 in IET Nanobiotechnology
Verified
Journal Article
Open access
VPVíctor H. Pérez-González
Víctor H. Pérez-González
RGRoberto Carlos Gallo‐Villanueva
Roberto Carlos Gallo‐Villanueva
Sergio Camacho-LeonSergio Camacho-Leon
Sergio Camacho-Leon
JGJose Isabel Gomez‐Quiñones
Jose Isabel Gomez‐Quiñones
JRJose Rodriguez-Delgado
Jose Rodriguez-Delgado
SMSergio O. Martínez-Chapa
Sergio O. Martínez-Chapa
Circulating tumour cells (CTCs) are active participants in the metastasis process and account for ∼90% of all cancer deaths. As CTCs are admixed with a very large amount of erythrocytes, leukocytes, and platelets in blood, CTCs are very rare, making their isolation, capture, and detection a major technological challenge. Microfluidic technologies have opened‐up new opportunities for the screening of blood samples and the detection of CTCs or other important cancer biomarker‐proteins. In this study, the authors have reviewed the most recent developments in microfluidic devices for cells/biomarkers manipulation and detection, focusing their attention on immunomagnetic‐affinity‐based devices, dielectrophoresis‐based devices, surface‐plasmon‐resonance microfluidic sensors, and quantum‐dots‐based sensors.