ARACELI SÁNCHEZ ALVAREZ

Dr. ARACELI SÁNCHEZ ALVAREZ


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
DRDenise Rivera
Denise Rivera
GQGabriela Elizabeth Quintanilla-Villanueva
Gabriela Elizabeth Quintanilla-Villanueva
DMDonato Luna Moreno
Donato Luna Moreno
AAARACELI SÁNCHEZ ALVAREZ
ARACELI SÁNCHEZ ALVAREZ
JRJose Rodriguez-Delgado
Jose Rodriguez-Delgado
MRMelissa Rodríguez-Delgado
Melissa Rodríguez-Delgado
Plastic pollution, particularly from microplastics (MPs) and nanoplastics (NPs), has become a critical environmental and health concern due to their widespread distribution, persistence, and potential toxicity. MPs and NPs originate from primary sources, such as cosmetic microspheres or synthetic fibers, and secondary fragmentation of larger plastics through environmental degradation. These particles, typically less than 5 mm, are found globally, from deep seabeds to human tissues, and are known to adsorb and release harmful pollutants, exacerbating ecological and health risks. Effective detection and quantification of MPs and NPs are essential for understanding and mitigating their impacts. Current analytical methods include physical and chemical techniques. Physical methods, such as optical and electron microscopy, provide morphological details but often lack specificity and are time-intensive. Chemical analyses, such as Fourier transform infrared (FTIR) and Raman spectroscopy, offer molecular specificity but face challenges with smaller particle sizes and complex matrices. Thermal analytical methods, including pyrolysis gas chromatography–mass spectrometry (Py-GC-MS), provide compositional insights but are destructive and limited in morphological analysis. Emerging (bio)sensing technologies show promise in addressing these challenges. Electrochemical biosensors offer cost-effective, portable, and sensitive platforms, leveraging principles such as voltammetry and impedance to detect MPs and their adsorbed pollutants. Plasmonic techniques, including surface plasmon resonance (SPR) and surface-enhanced Raman spectroscopy (SERS), provide high sensitivity and specificity through nanostructure-enhanced detection. Fluorescent biosensors utilizing microbial or enzymatic elements enable the real-time monitoring of plastic degradation products, such as terephthalic acid from polyethylene terephthalate (PET). Advancements in these innovative approaches pave the way for more accurate, scalable, and environmentally compatible detection solutions, contributing to improved monitoring and remediation strategies. This review highlights the potential of biosensors as advanced analytical methods, including a section on prospects that address the challenges that could lead to significant advancements in environmental monitoring, highlighting the necessity of testing the new sensing developments under real conditions (composition/matrix of the samples), which are often overlooked, as well as the study of peptides as a novel recognition element in microplastic sensing.

23 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
DMDonato Luna Moreno
Donato Luna Moreno
AAARACELI SÁNCHEZ ALVAREZ
ARACELI SÁNCHEZ ALVAREZ
IIIgnacio Islas-Flores
Ignacio Islas-Flores
BCBlondy Canto-Canche
Blondy Canto-Canche
MCMildred Carrillo-Pech
Mildred Carrillo-Pech
MRMelissa Rodríguez-Delgado
Melissa Rodríguez-Delgado
Black Sigatoka is a disease that occurs in banana plantations worldwide. This disease is caused by the hemibiotrophic fungus Pseudocercospora fijiensis, whose infection results in a significant reduction in both product quality and yield. Therefore, detection and identification in the early stages of this pathogen in plants could help minimize losses, as well as prevent the spread of the disease to neighboring cultures. To achieve this, a highly sensitive SPR immunosensor was developed to detect P. fijiensis in real samples of leaf extracts in early stages of the disease. A polyclonal antibody (anti-HF1), produced against HF1 (cell wall protein of P. fijiensis) was covalently immobilized on a gold-coated chip via a mixed self-assembled monolayer (SAM) of alkanethiols using the EDC/NHS method. The analytical parameters of the biosensor were established, obtaining a limit of detection of 11.7 µg mL−1, a sensitivity of 0.0021 units of reflectance per ng mL−1 and a linear response range for the antigen from 39.1 to 122 µg mL−1. No matrix effects were observed during the measurements of real leaf banana extracts by the immunosensor. To the best of our knowledge, this is the first research into the development of an SPR biosensor for the detection of P. fijiensis, which demonstrates its potential as an alternative analytical tool for in-field monitoring of black Sigatoka disease.

11 October 2024 in Analytica
Verified
Journal Article
Open access
PDF file
GQGabriela Elizabeth Quintanilla-Villanueva
Gabriela Elizabeth Quintanilla-Villanueva
AAARACELI SÁNCHEZ ALVAREZ
ARACELI SÁNCHEZ ALVAREZ
RNRaisa Estefania Núñez-Salas
Raisa Estefania Núñez-Salas
MRMelissa Rodríguez-Delgado
Melissa Rodríguez-Delgado
DMDonato Luna Moreno
Donato Luna Moreno
Juan Francisco Villarreal-ChiuJuan Francisco Villarreal-Chiu
Juan Francisco Villarreal-Chiu
This study examines the significant impact of bacterial, algal, and fungal toxins on foodborne illnesses, and stresses the importance of advanced detection techniques, such as high-performance liquid chromatography (HPLC)-based methodologies. It emphasizes the urgent need for further advancements in these techniques to ensure food safety, as they offer significant benefits, including low detection limits and the ability to be combined with other techniques to detect a wide range of toxins. In this regard, HPLC has emerged as a versatile and sensitive analytical technique for this purpose. Various HPLC methods, often enhanced with detectors such as ultraviolet (UV), fluorescence (FD), and mass spectrometry (MS), have been developed to identify and quantify microbial toxins in a wide variety of food samples. Recent advancements include HPLC-FD methods that utilize the natural fluorescence of certain aflatoxins, improving detection sensitivity. HPLC-MS/MS and UHPLC-MS/MS techniques offer high selectivity and sensitivity, making them suitable for detecting a wide range of toxins in trace quantities. The adaptability of HPLC, combined with innovative detection technologies and sample preparation methods, holds significant potential for enhancing food safety monitoring and reducing the global burden of foodborne diseases.

25 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DMDonato Luna Moreno
Donato Luna Moreno
AAARACELI SÁNCHEZ ALVAREZ
ARACELI SÁNCHEZ ALVAREZ
MRMelissa Rodríguez-Delgado
Melissa Rodríguez-Delgado
The importance of the monitoring of thickness and rate deposition is indispensable for the fabrication of thin film sensors, such as SPR sensors. The sensitivity of SPR responses varies with the thickness of the film, as well as the linear range. Thus, in the present work, we presented an experimental study of the plasmonic response of Cr/Au thin films deposited onto glass slides by evaporation, based on both a rotation and no-rotation system. The results show that the thickness of the gold film varies from 240 to 620 Å, depending on the glass slide position. The SPR response curves obtained experimentally were compared with simulated plasmonic responses and different parameters such as resonance angle, and the depth, slope and half-width of the SPR curve were analysed.

15 January 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
AAARACELI SÁNCHEZ ALVAREZ
ARACELI SÁNCHEZ ALVAREZ
DMDonato Luna Moreno
Donato Luna Moreno
OSOscar Silva
Oscar Silva
MRMelissa Rodríguez-Delgado
Melissa Rodríguez-Delgado
Mezcal is a traditional Mexican spirit produced by distilling fermented agave, with a unique taste directly related to its volatile compound composition. Thus, the present research proposed the surface plasmon resonance (SPR) technique as a potential method to differentiate mezcals, studying several parameters at angular interrogations and at a fixed angle. The study evaluated eight mezcals from different agave species using SPR and gas chromatography-mass spectrometry (GC-MS). Despite the similarities in mezcal spirits corresponding to the same ethanol content and the same artisanal method, it was possible to obtain well-differentiated characteristics by SPR parameters, such as the width of the curve, the resonant angle, and reflectance intensities. Therefore, it was possible to demonstrate the potential use of the SPR technique as a rapid first approach to a screening test to differentiate types of spirits.

1 February 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
GQGabriela Elizabeth Quintanilla-Villanueva
Gabriela Elizabeth Quintanilla-Villanueva
OROsvaldo Rodríguez-Quiroz
Osvaldo Rodríguez-Quiroz
AAARACELI SÁNCHEZ ALVAREZ
ARACELI SÁNCHEZ ALVAREZ
JRJose Rodriguez-Delgado
Jose Rodriguez-Delgado
Juan Francisco Villarreal-ChiuJuan Francisco Villarreal-Chiu
Juan Francisco Villarreal-Chiu
MRMelissa Rodríguez-Delgado
Melissa Rodríguez-Delgado
Glycine is an essential amino acid involved in synthesizing a variety of important biomolecules, and its concentration can influence numerous biochemical processes, including the severity of symptoms in a wide range of conditions in humans, such as cancer, schizophrenia, major depression, and diabetes. While a few costly or labour-intensive methods are currently available, we have developed a new enzymatic biosensor that can accurately measure glycine levels with remarkable simplicity. By employing immobilized laccase enzymes in combination with a surface plasmon resonance (SPR) device, our system achieved a limit of detection (LOD) of 9.95 mM and a limit of quantification (LOQ) of 33.19 mM. In addition, it demonstrated a recovery rate of 97.64 ± 7.71%. Moreover, the biosensor maintained consistent signal intensity over 21 days and supported a total of 60 analyses using the same immobilized enzyme setup, demonstrating excellent reusability. Notably, this study marks the first time glycine has been determined using an enzymatic SPR-based platform.