Andrzej Małysa

Dr. Andrzej Małysa

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
WFWojciech Florjański
Wojciech Florjański
AMAndrzej Małysa
Andrzej Małysa
SOSylwia Orzeszek
Sylwia Orzeszek
JSJoanna Smardz
Joanna Smardz
AOAnna Olchowy
Anna Olchowy
Mieszko WieckiewiczMieszko Wieckiewicz
Mieszko Wieckiewicz
Temporomandibular disorders (TMD) have multifactorial and complex etiology. Regardless of their etiology, all those conditions may result in centrally mediated chronic muscle pain, myalgia, myofascial pain, myofibrotic contracture, myosistis, myospasm, headache and a variety of neck, shoulder, upper back and lower back pain. Biofeedback (BF) is one of methods that has been used for more than 50 years in rehabilitation to facilitate normal movement patterns after injuries. Some studies suggest that biofeedback may be an effective treatment option for patients with different muscle disorders. The aim of this study was to evaluate the efficiency of biofeedback in masticatory muscle activity management in the light of current medical literature. The authors followed the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines for this systematic review. The authors searched the MEDLINE, Scopus, Web of Science, CINAHL databases to identify relevant publications. Finally 10 papers were included. Most of the selected studies showed a significant correlation between biofeedback usage and reduction of masticatory muscle activity. By analyzing qualified studies, it can be concluded that biofeedback can be an effective tool in masticatory muscle activity management.

2 May 2019 in Polymers
Verified
Journal Article
Open access
PDF file
WFWojciech Florjański
Wojciech Florjański
SOSylwia Orzeszek
Sylwia Orzeszek
AOAnna Olchowy
Anna Olchowy
NGNatalia Grychowska
Natalia Grychowska
WWWlodzimierz Wieckiewicz
Wlodzimierz Wieckiewicz
Mieszko WieckiewiczMieszko Wieckiewicz
Mieszko Wieckiewicz
Guided tissue/bone regeneration (GTR/GBR) is a widely used procedure in contemporary dentistry. To achieve the required results of tissue regeneration, soft tissues that reproduce quickly are separated from the slow-growing bone tissue by membranes. Many types of membranes are currently in use, but none of them fulfil all of the desired features. To address this issue, further research on developing new membranes with better separation characteristics, such as membrane modification, is needed. Many of the current innovative modified materials are still in the phase of in vitro and experimental studies. A collective review on new trends in membrane modification to GTR/GBR is needed due to the widespread use of polymeric membranes and the constant development in the field of dentistry. Therefore, the aim of this review was to present an overview of polymeric membrane modifications to the GTR/GBR reported in the literature. The authors searched databases, including PubMed, SCOPUS, Web of Science, and OVID, for relevant studies that were published during 1999–2019. The following keywords were used: guided tissue regeneration, membranes, coating, and modification. A total of 17 papers were included in this review. Furthermore, the articles were divided into three groups that were based on the type of membrane modification: antibiotic coating, ion-use modifications, and others modifications, thus providing an overview of current existing knowledge in the field and encouraging further research. The results of included studies on modified barrier membranes seem to be promising, both in terms of safety and benefits for patients. However, modifications result in a large spectrum of effects. Further clinical studies are needed on a large group of patients to clearly confirm the effects that were observed in animal and in vitro studies.

25 May 2023 in Dental and Medical Problems
Verified
Journal Article
Open access
Anna Paradowska-StolarzAnna Paradowska-Stolarz
Anna Paradowska-Stolarz
Mieszko WieckiewiczMieszko Wieckiewicz
Mieszko Wieckiewicz
MMMarcin Mikulewicz
Marcin Mikulewicz
AMAndrzej Małysa
Andrzej Małysa
Irena Duś-IlnickaIrena Duś-Ilnicka
Irena Duś-Ilnicka
JWJoanna Wezgowiec
Joanna Wezgowiec
Three-dimensional (3D) printing technology has brought much innovation to medicine and has been successfully adopted in many areas of dentistry. Although 3D printing techniques are being increasingly used, their advantages and disadvantages still need to be investigated, particularly with regard to the materials used in dentistry. Dental materials should be biocompatible and non-cytotoxic, and have sufficient mechanical integrity in the oral environment in which they are intended for use. The present work aimed to identify and compare the mechanical properties of three 3D-printable resins. The materials included IBT Resin, BioMed Amber Resin and Dental LT Clear Resin. The Formlabs Form 2 printer was used. A tensile strength test was performed on 10 specimens of each resin. Tensile modulus was measured on 2-millimeter-thick dumbbell-shaped specimens, 75 mm in length and 10 mm in width. The 10 specimens of each resin were mounted between the grips of a universal testing machine (Z10-X700). The results showed that BioMed Amber specimens cracked easily, yet no deformation was observed. The amount of force used to test the tensility of the specimens was the lowest for IBT Resin, while it was the highest for Dental LT Clear Resin. IBT Resin was the weakest material, whereas Dental Clear LT Resin was the strongest.

1 January 2020 in Acta of Bioengineering and Biomechanics
Verified
Journal Article
Open access
AMAndrzej Małysa
Andrzej Małysa
JWJoanna Wezgowiec
Joanna Wezgowiec
DDDariusz Danel
Dariusz Danel
KBKlauss Boening
Klauss Boening
KWKatarzyna Walczak
Katarzyna Walczak
Mieszko WieckiewiczMieszko Wieckiewicz
Mieszko Wieckiewicz
Purpose: The aim of the study was to evaluate the shear bond strength of CAD/CAM ceramics to dentin after cementation with conventional or self-adhesive resin cements. Methods: Three self-adhesive, self-etching cements (Panavia SA, RelyX U200, Maxcem Elite), and one conventional cement (Panavia V5), were selected to lute three CAD/CAM ceramics (IPS Empress CAD, IPS e.max CAD, IPS e.max ZirCAD) onto the dentin. The bond strength was evaluated using a shear strength test according to the PN-EN ISO 29022:2013-10. Evaluation of the differences was performed using the Statistica software. Failure modes were analyzed using a light microscope. Results: All the studied cements differed (regardless of the ceramic type) in the bond strength. The highest bond strength was observed in Panavia V5, lower – in RelyX U200 and Panavia SA, and the lowest – in Maxcem. For IPS e.max ZirCAD, it was observed that compared to Panavia V5, the other cements were characterized by a significantly higher bond strength. For the IPS Empress CAD and the IPS e.max CAD, Panavia V5 displayed the highest bond strength. For all the studied self-adhesive cements, the failure of adhesion between the cement and dentin was predominant mode. Conclusions: Significant differences were found in the shear bond strengths of the CAD/CAM ceramics luted to dentin using tested self-adhesive and conventional cements. The bond strength depended on the combination of ceramic and cement. The IPS e.max ZirCAD had the highest bond strength to dentin after cementation with RelyX U200, while the IPS Empress CAD and IPS e.max CAD – with Panavia V5.

AOAnna Olchowy
Anna Olchowy
Mieszko WieckiewiczMieszko Wieckiewicz
Mieszko Wieckiewicz
AMAndrzej Małysa
Andrzej Małysa
COCyprian Olchowy
Cyprian Olchowy
Shear wave elastography (SWE) is an objective and reliable method for the assessment of muscles and internal organs. Every organ exhibits its own stiffness characteristics and hence requires individual reference values. We aimed to determine the reference values of stiffness of the masseter muscle in healthy adult individuals using SWE. We analyzed the data of 140 participants (74 men, 66 women) with a median age of 50 years. The overall mean elasticity was 10.67 ± 1.77 kPa. The average values were lower by 2.25 kPa (9.15%) in women compared to men (9.48 ± 1.47 kPa vs. 11.73 ± 1.27 kPa; p < 0.0001). The values of stiffness increased with age, with a correlation coefficient of about 0.35 and a p < 0.0001. Age was a significant influencing factor of masseter muscle stiffness. The left and right masseters had similar stiffness. We conclude that stiffness values are significantly lower in women than in men with a difference of 9%. Age significantly influences the stiffness of masseter muscle, and the values of stiffness increase significantly with age, particularly in men. However, further studies are required to determine the precise ranges of stiffness accounting for age and sex in healthy subjects and people with disorders and conditions of the masticatory system.

30 April 2024 in Dental and Medical Problems
Verified
Journal Article
Open access
JWJoanna Wezgowiec
Joanna Wezgowiec
AMAndrzej Małysa
Andrzej Małysa
Mieszko WieckiewiczMieszko Wieckiewicz
Mieszko Wieckiewicz
The mechanical reliability of occlusal splints and their long-term behavior are significant factors determining the clinical outcome of temporomandibular disorder (TMD) therapy. However, improvements are still needed in this area. This in vitro study aimed to (1) compare the hardness and flexural properties of materials manufactured using 3 techniques for occlusal splint fabrication (conventional heat curing, thermoforming followed by light curing, and three-dimensional (3D) printing) and (2) analyze the effect of artificial aging on the properties of the materials. A total of 120 disc-shaped specimens were manufactured for the Shore D hardness evaluation, and 120 bar-shaped specimens were fabricated for the flexural properties evaluation (n = 15 for each group). Each material was tested in 2 groups of specimens, non-aged and artificially aged (stored for 90 days in water at 37°C). Statistical differences were assessed using one-way or two-way parametric analysis of variance (ANOVA) with Tukey's or Šídák's post-hoc test, or the non-parametric KruskalWallis test with Dunn's post-hoc test. A p-value of less than 0.05 was considered statistically significant. The mechanical properties of the materials varied significantly. Among the non-aged materials, the 3D-printed resin exhibited the highest Shore D hardness (85.3D), but it decreased significantly after 90 days of water storage (80.4D, p < 0.0001). The unpolished heat curing acrylic showed the highest resistance to artificial aging (p = 0.0436). However, its hardness decreased significantly after polishing (81.0D vs. 83.4D, p = 0.0015). The conventional heat curing material also exhibited superior flexural properties (σ = 89.63 MPa, E = 2616 MPa). All tested materials were susceptible to deterioration due to aging. The conventional method of occlusal splint fabrication remains the optimal choice, particularly for long-term use. However, it is still necessary to develop materials that are resistant to aging in order to ensure successful clinical performance.