Nima Alimoradi

Mr. Nima Alimoradi

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Gabriel ClarkeGabriel Clarke
Gabriel Clarke
Brenna HartseBrenna Hartse
Brenna Hartse
AAAmir Ehsan Niaraki Asli
Amir Ehsan Niaraki Asli
MTMehrnoosh Taghavimehr
Mehrnoosh Taghavimehr
NHNiloofar Hashemi
Niloofar Hashemi
Nicole HashemiNicole Hashemi
Nicole Hashemi
Organ-on-chip devices have provided the pharmaceutical and tissue engineering worlds much hope since they arrived and began to grow in sophistication. However, limitations for their applicability were soon realized as they lacked real-time monitoring and sensing capabilities. The users of these devices relied solely on endpoint analysis for the results of their tests, which created a chasm in the understanding of life between the lab the natural world. However, this gap is being bridged with sensors that are integrated into organ-on-chip devices. This review goes in-depth on different sensing methods, giving examples for various research on mechanical, electrical resistance, and bead-based sensors, and the prospects of each. Furthermore, the review covers works conducted that use specific sensors for oxygen, and various metabolites to characterize cellular behavior and response in real-time. Together, the outline of these works gives a thorough analysis of the design methodology and sophistication of the current sensor integrated organ-on-chips.

10 February 2022 in Advanced Healthcare Materials
Verified
Journal Article
Open access
PDF file
SASaurabh S. Aykar
Saurabh S. Aykar
NANima Alimoradi
Nima Alimoradi
MTMehrnoosh Taghavimehr
Mehrnoosh Taghavimehr
Reza MontazamiReza Montazami
Reza Montazami
Nicole HashemiNicole Hashemi
Nicole Hashemi
Mimicking microvascular tissue microenvironment in vitro calls for a cytocompatible technique of manufacturing biocompatible hollow microfibers suitable for cell‐encapsulation/seeding in and around them. The techniques reported to date either have a limit on the microfiber dimensions or undergo a complex manufacturing process. Here, a microfluidic‐based method for cell seeding inside alginate hollow microfibers is designed whereby mouse astrocytes (C8‐D1A) are passively seeded on the inner surface of these hollow microfibers. Collagen I and poly‐d‐lysine, as cell attachment additives, are tested to assess cell adhesion and viability; the results are compared with nonadditive‐based hollow microfibers (BARE). The BARE furnishes better cell attachment and higher cell viability immediately after manufacturing, and an increasing trend in the cell viability is observed between Day 0 and Day 2. Swelling analysis using percentage initial weight and width is performed on BARE microfibers furnishing a maximum of 124.1% and 106.1%, respectively. Degradation analysis using weight observed a 62% loss after 3 days, with 46% occurring in the first 12 h. In the frequency sweep test performed, the storage modulus (G′) remains comparatively higher than the loss modulus (G″) in the frequency range 0–20 Hz, indicating high elastic behavior of the hollow microfibers.

3 August 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
NJNianyu Jiang
Nianyu Jiang
MSMarissa Roghair Stroud
Marissa Roghair Stroud
SBSoma Banerjee
Soma Banerjee
NANima Alimoradi
Nima Alimoradi
MNMarit Nilsen-Hamilton
Marit Nilsen-Hamilton
PSPranav Shrotriya
Pranav Shrotriya
We report an aptasensor based monitoring of quorum-sensing molecules (N-butanoyl-L-homoserine lactone (C4HSL)), diffusion in microbial growth supporting hydrogels. C4HSL, a microbially-produced secreted molecule, is an integral part of intercellular communication that shapes the structure and function of microbial communities. The nanoporous anodic aluminum oxide (NAAO)- membrane-based aptasensors sensitized with C4HSL-binding aptamers were used for detecting local concentrations of C4HSL. Binding of C4HSL molecules to membrane-immobilized aptamers alters transmembrane impedance, which is monitored to determine local concentrations. Aptasensor responses are first calibrated, and the specificity of the aptasensor response to C4HSL is evaluated by exposure to another quorum-sensing signal molecule, N-(3-oxododecanoyl)-L-homoserine lactone (3-oxo-C12HSL), that is also produced by the same organism but does not bind the aptamer. Multiple calibrated aptasensors fabricated on a single membrane are mounted on the surface of the gel, close to a circular cavity filled with C4HSL. The aptasensor responses are recorded to monitor the time-dependent diffusion of C4HSL from the cavity into the surrounding gel. The aptasensor response measured with a microcontroller-based reader is compared with measurements obtained with a commercial potentiostat to validate the performance of the reader and aptasensor system. The aptasensor measurements are used in computational models to estimate the diffusion coefficient and model the 4D spatial and temporal distribution of C4HSL concentration in the soil-mimic gels. Additionally, biosensing bacterial cultures expressing fluorescent molecules are used to validate the diffusion of C4HSL from a circular cavity in the gel substrate.

11 March 2022 in bioRxiv
Verified
Preprint
Open access
PDF file
NANima Alimoradi
Nima Alimoradi
VNVahid Nasirian
Vahid Nasirian
SASaurabh S. Aykar
Saurabh S. Aykar
MMMarilyn McNamara
Marilyn McNamara
ANAmir Ehsan Niaraki-Asli
Amir Ehsan Niaraki-Asli
Nicole HashemiNicole Hashemi
Nicole Hashemi
The manufacturing of 3D cell scaffoldings provides advantages for modeling diseases and injuries by physiologically relevant platforms. A triple-flow microfluidic device was developed to rapidly fabricate alginate/graphene hollow microfibers based on the gelation of alginate induced with CaCl 2 . This five-channel pattern actualized continuous mild fabrication of hollow fibers under an optimized flowing rate ratio of 300: 200: 100 μL.min −1 . The polymer solution was 2.5% alginate in 0.1% graphene, and a 30% polyethylene glycol solution was used as the sheath and core solutions. The morphology and physical properties of microstructures were investigated by scanning electron microscopy, electrochemical, and surface area analyzers. Subsequently, these conductive microfibers’ biocompatibility was studied by encapsulating mouse astrocyte cells within these scaffolds. The cells could successfully survive both the manufacturing process and prolonged encapsulation for up to 8 days. These unique 3D hollow scaffolds could significantly enhance the available surface area for nutrient transport to the cells. In addition, these conductive hollow scaffolds illustrated unique advantages such as 0.728 cm 3 .gr −1 porosity and twice more electrical conductivity in comparison to alginate scaffolds. The results confirm the potential of these scaffolds as a microenvironment that supports cell growth.