Marios Loucas

Dr. Marios Loucas


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2021 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
PKPhilipp Kriechling
Philipp Kriechling
RLRafael Loucas
Rafael Loucas
MLMarios Loucas
Marios Loucas
FCFabio Casari
Fabio Casari
Philipp FürnstahlPhilipp Fürnstahl
Philipp Fürnstahl
KWKarl Wieser
Karl Wieser
Background: To achieve an optimal clinical outcome in reverse total shoulder arthroplasty (RSA), accurate placement of the components is essential. The recently introduced navigation technology of augmented reality (AR) through head-mounted displays (HMD) offers a promising new approach to visualize the anatomy and navigate component positioning in various orthopedic surgeries. We hypothesized that AR through HMD is feasible, reliable, and accurate for guidewire placement in RSA baseplate positioning. Methods: Twelve human cadaver shoulders were scanned with computed tomography (CT) and RSA baseplate positioning was 3-D planned using dedicated software. The shoulders were prepared through a deltopectoral approach and an augmented reality hologram was superimposed using the HMD Microsoft HoloLense. The central guidewire was then navigated through the HMD to achieve the planned entry point and trajectory. Postoperatively, the shoulders were CT-scanned a second time and the deviation from the planning was calculated. Results: The mean deviation of the entry point was 3.5 mm ± 1.7 mm (95% CI 2.4 mm; 4.6 mm). The mean deviation of the planned trajectory was 3.8° ± 1.7° (95% CI 2.6°; 4.9°). Conclusion: Augmented reality seems feasible and reliable for baseplate guidewire positioning in reverse total shoulder arthroplasty. The achieved values were accurate.

1 April 2021 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Open access
PKPhilipp Kriechling
Philipp Kriechling
RLRafael Loucas
Rafael Loucas
MLMarios Loucas
Marios Loucas
TKTabea Künzler
Tabea Künzler
CGChristian Gerber
Christian Gerber
KWKarl Wieser
Karl Wieser
The use of reverse total shoulder arthroplasty (RTSA) has spread worldwide as a result of an expansion of indications and an aging society. However, the value of RTSA for very old patients is rarely analyzed. This study was conducted to investigate the outcome of primary RTSA in patients older than 80 years. We identified 171 shoulders (159 patients) treated with RTSA at an age of more than 80 years between January 2005 and March 2018. The primary outcome parameters were Subjective Shoulder Value (SSV) and the Constant-Murley score, mortality, complications, and reoperation rates. Secondary outcomes were adverse radiographic outcomes. A minimum follow-up of 1 year was accepted in 14 patients (8%) because of these patients' older age. We included 171 cases (159 patients; 120 female) with a mean age of 84 ± 3 years (range 80.1-94). The main indication for RTSA was cuff tear arthropathy (43%), isolated rotator cuff tear (22%), and fracture (21%). A total of 136 patients (79%) were eligible for physical examination with a mean follow-up of 41 ± 25 months (12-121). Relative Constant-Murley scores improved significantly from 39% ± 19% to 77% ± 16% and SSV from 31% ± 18% to 74% ± 22%. The range of motion and force improved significantly as well. The surgical site complication rate was 30%, with a reoperation rate of 8% (13 patients) mainly due to fracture and glenoid loosening. The overall mortality was 16% with a mean time to death of 53 ± 31 months (95% confidence interval 15, 120), thereby no higher than the age-adjusted, expected mortality rate without this procedure. Despite a quite high postoperative complication rate, RTSA is a valid therapeutic option in patients older than 80 years, with an unexpectedly low medical complication rate and good to excellent improvement of shoulder function and pain.

25 February 2022 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
SLSora Linder
Sora Linder
LWLeonard Walle
Leonard Walle
MLMarios Loucas
Marios Loucas
RLRafael Loucas
Rafael Loucas
Onno FrerichsOnno Frerichs
Onno Frerichs
Hisham FansaHisham Fansa
Hisham Fansa
Enhanced recovery after surgery (ERAS) is established for autologous breast reconstruction. ERAS leads to a shortened hospital stay and improved outcome after elective surgery. In this retrospective, two-center case–control study, we compared two different treatment regimens for patients undergoing a DIEP-flap breast reconstruction from two centers, one with an established ERAS protocol and one without. All patients with DIEP breast reconstructions over the period of 12 months were included. The primary outcome measure was the length of hospital stay (LOS) in days. A total of 79 patients with 95 DIEP-flaps were analyzed. In group A (ERAS) 42 patients were operated with DIEP flaps, in group B (non-ERAS) 37 patients. LOS was significantly reduced in the ERAS group (4.51 days) compared to the non-ERAS group (6.32; p < 0.001). Multivariate analysis showed that, in group A, LOS is significantly affected by surgery duration. BMI in the ERAS group had no effect on LOS. In group B a higher BMI resulted in a significantly higher LOS. In multivariate analysis, neither age nor type for surgery (primary/secondary/after neoadjuvant therapy, etc.) affected LOS. In both groups, no systemic or flap-related complications were observed. Comparing two reconstructive centers with and without implemented ERAS, ERAS led to a significantly decreased LOS for all patients. ERAS implementation does not result in an increased complication rate or flap loss. Postoperative pain can be well managed with basic analgesia using NSAID when intraoperative blocks are applied. The reduced use of opioids was well tolerated. With implementation of ERAS the recovery experience can be enhanced making autologous breast reconstructions more available and attractive for various patients.

14 June 2025 in Cells
Verified
Journal Article
Open access
PDF file
TSTom Schimanski
Tom Schimanski
RLRafael Loucas
Rafael Loucas
MLMarios Loucas
Marios Loucas
OFOliver Heinrich Felthaus
Oliver Heinrich Felthaus
VBVanessa Brébant
Vanessa Brébant
Lukas PrantlLukas Prantl
Lukas Prantl
Background: Histological and immunohistochemical analyses of adipose tissue are essential for evaluating the quality and functionality of lipoaspirates in regenerative medicine and fat grafting procedures. These methods provide insights into tissue viability, cellular subtypes, and extracellular matrix (ECM) composition—all factors influencing graft retention and clinical outcomes. Purpose: This scoping review aims to summarize the most commonly used staining methods and their applications in the histology and immunohistochemistry of adipose tissue. By exploring qualitative and quantitative markers, we seek to guide researchers in selecting the appropriate methodologies for addressing experimental and translational research. Methods: A systematic search was conducted using PubMed, Ovid, and the Cochrane Library databases from inception to 2024, employing Boolean operators (“lipoaspirate” OR “fat graft” OR “gauze rolling” OR “decantation” OR “coleman fat” OR “celt” OR “nanofat” OR “lipofilling” OR “human fat” AND “histol*”). Studies were included if they utilized histology or immunohistochemistry on undigested human adipose tissue or its derivatives. The inclusion criteria focused on peer-reviewed, English-language studies reporting quantitative and qualitative data on adipose tissue markers. Results: Out of 166 studies analyzed, hematoxylin–eosin (H&E) was the most frequently employed histological stain (152 studies), followed by Masson Trichrome and Sudan III. Immunohistochemical markers such as CD31, CD34, and perilipin were extensively used to distinguish stromal vascular fraction (SVF) cells, adipocytes, and inflammatory processes. Studies employing semiquantitative scoring demonstrated enhanced comparability, particularly for fibrosis, necrosis, and oil cyst evaluation. Quantitative analyses focused on SVF cell density, mature adipocyte integrity, and ECM composition. Methodological inconsistencies, particularly in preparation protocols, were observed in 25 studies. Conclusions: This review highlights the critical role of histological and immunohistochemical methods in adipose tissue research. H&E staining remains the cornerstone for general tissue evaluation in the clinical context, while specialized stains and immunohistochemical markers allow for detailed analyses of specific cellular and ECM components in experimental research. Standardizing preparation and evaluation protocols will enhance interstudy comparability and support advancements in adipose tissue-based therapies.

29 September 2022 in JSES International
Verified
Journal Article
Open access
TSThomas Stojanov
Thomas Stojanov
LALaurent Audigé
Laurent Audigé
LMLinda Modler
Linda Modler
SASoheila Aghlmandi
Soheila Aghlmandi
CAChristian Appenzeller-Herzog
Christian Appenzeller-Herzog
AMAndreas Marc Müller
Andreas Marc Müller
The identification of factors that specify prognostic models for postoperative results should be based on the best scientific evidence and expert assessment. We aimed to identify, map, and evaluate potential prognostic factors for the improvement of shoulder function in patients undergoing arthroscopic rotator cuff repair. Longitudinal primary studies of arthroscopic rotator cuff repair reporting any multivariable factor analyses for shoulder function improvement with an endpoint assessment of at least 6 months were included. We systematically searched EMBASE, Medline, and Scopus for articles published between January 2014 and June 2021. The risk of bias of included studies and the quality of evidence were assessed using the Quality in Prognosis Studies tool and an adapted Grading of Recommendations, Assessment, Development, and Evaluations framework. Overall, 24 studies including 73 outcome analyses were included. We classified younger age and smaller tear size as probably prognostic for a greater improvement in objective outcomes. Shorter symptom duration, absence of a worker compensation claim, low preoperative level of functional status, and high preoperative pain level were classified as probably prognostic for greater improvement in patient-reported outcome measures. The quality of the synthesized evidence was low. Twenty-one studies had an overall high risk of bias. Six potential prognostic factors for shoulder function after arthroscopic rotator cuff repair were identified. Along with ongoing expert opinion assessments, they will feed into a prognostic model-building process.

Verified
Journal Article
Open access
PDF file
RLRafael Loucas
Rafael Loucas
MLMarios Loucas
Marios Loucas
SLSebastian Leitsch
Sebastian Leitsch
KDKatarina Danuser
Katarina Danuser
GRGabriela Reichard
Gabriela Reichard
THThomas Holzbach
Thomas Holzbach
Methods for assessing three-dimensional (3D) breast volume are becoming increasingly popular in breast surgery. However, the precision of intraoperative volumetric assessment is still unclear. Until now, only non-validated scanning systems have been used for intraoperative volumetric analyses. This study aimed to assess the feasibility, handling, and accuracy of a commercially available, validated, and portable device for intraoperative 3D volumetric evaluation. All patients who underwent breast surgery from 2020 to 2022 were identified from our institutional database. Intraoperative 3D volumetric assessments of 103 patients were included in this study. Standardized 3D volumetric measurements were obtained 3 months postoperatively to compare the intraoperatively generated volumetric assessment. All of the study participants were women with a mean age of 48.3 ± 14.7 years (range: 20–89). The mean time for intraoperative volumetric assessment was 8.7 ± 2.6 min. The postoperative 3D volumetric assessment, with a mean volume of 507.11 ± 206.29 cc, showed no significant difference from the intraoperative volumetric measurements of 504.24 ± 276.61 cc (p = 0.68). The mean absolute volume difference between the intraoperative simulations and postoperative results was 27.1 cc. Intraoperative 3D volumetric assessment using the VECTRA H2 imaging system seems to be a feasible, reliable, and accurate method for measuring breast volume. Based on this finding, we plan to investigate whether volumetric objective evaluations will help to improve breast symmetry in the future.