In this paper, a Microgrid (MG) test model based on the 14-busbar IEEE distribution system is proposed. This model can constitute an important research tool for the analysis of electrical grids in its transition to Smart Grids (SG). The benchmark is used as a base case for power flow analysis and quality variables related with SG and holds distributed resources. The proposed MG consists of DC and AC buses with different types of loads and distributed generation at two voltage levels. A complete model of this MG has been simulated using the MATLAB/Simulink environmental simulation platform. The proposed electrical system will provide a base case for other studies such as: reactive power compensation, stability and inertia analysis, reliability, demand response studies, hierarchical control, fault tolerant control, optimization and energy storage strategies.
In this paper an exhaustive bibliographical revision of the mathematical methods used for the optimal selection and location of reactive power compensating elements is developed, the results obtained by different authors for different objective functions are analyzed and a scientific problem in the conflict that the electric variables show when analyzed individually is identified; thus demonstrating the need to analyze this problem in a multi-criteria way and taking into account topologies of distribution grids with distributed generation and energy storage. This research demonstrates that reactive power compensation in distribution grids with distributed resources is a problem that must be analyzed from multiple criteria that consider several objective functions to be optimized; thus achieving a global solution that contemplates an optimal location and dimensioning of reactive power compensating elements that contribute to the joint improvement of the voltage profiles, minimization of power losses, harmonic mitigation, increased line capacity, voltage stability and power factor improvement, all of them to a minimum investment cost. A theoretical heuristic is also proposed to solve the described problem, based on the multicriteria optimization method.
In preparation for the electric mobility technological transition in Colombia, an impact assessment of the electric power system is required, considering the increasing loading that must be able to be managed in the future. In this paper, a plug-in electric vehicle (PEV) charging simulation methodology is developed in order to dimension the impact of this type of load on power grids. PEV electric properties, user charging behaviors, geographic location, trip distances, and other variables of interest are modeled from empirical or known probability distributions and later evaluated in different scenarios using Monte Carlo simulation and load flow analysis. This methodology is later applied to the transmission network of Antioquia (a department of Colombia) resulting in load increases of up to 40% on transmission lines and 20% on transformers in a high PEV penetration scenario in 2030, increases that are well within the expected grid capacity for that year, avoiding the need for additional upgrades.
1 October 2019 in Science of The Total Environment
In this research, an alternative methodology is proposed for the location of Static VAR Compensators (SVC) in power systems, considering the reconfiguration of reactive power flows through the optimal switching of the transmission stage, which resembles the contingency restriction N-1 usually considered in transmission expansion planning. Based on this methodology, the contingency index was determined, which made it possible to determine which is the contingency that generates the greatest voltage degradation in the system. For the quantification of reactive flows, optimal AC power flows were used, which minimize the operating costs of the power system subject to transmission line switching restrictions, line charge-ability, voltages and node angles. To determine the node in which the compensation should be placed, the contingency index criterion was used, verifying the voltage profile in the nodes. The proposed methodology was tested in the IEEE test systems of 9, 14 nodes and large-scale systems of 200, 500 and 2000 bus-bars; to verify that the proposed methodology is adequate, the stability of the EPS was verified. Finally, the model allows satisfactorily to determine the node in which the SVC is implemented and its compensation value.
The frequency of an electrical power system can be interpreted as an indicator of the equilibrium between generation and demand. Under fault conditions where this balance is disrupted, the Under-Frequency Load Shedding scheme is typically the ultimate resource employed to prevent the frequency from dropping to undesirable thresholds that could lead to a blackout. Smart loads have the capability to dynamically adjust their consumption in response to frequency variations, which has the potential to enhance frequency regulation and mitigate the need for abrupt load disconnection through the Under-Frequency Load Shedding scheme. The objective of this paper is to present a literature review of Under-Frequency Load Shedding schemes, an innovative approach to their classifications, and the introduction of a new category within these schemes that incorporates smart loads. Additionally, an overview of smart loads is included to be potentially employed in the design of new schemes and contribute to a shift in the operation philosophy, considering that the primary mission of electric power systems is to provide energy to loads rather than disconnecting them.
About Me
Universidad Pontificia Bolivariana Circular 1, 70-01 Medellin
Universidad Pontificia Bolivariana Circular 1, 70-01 Medellin