The frequency of an electrical power system can be interpreted as an indicator of the equilibrium between generation and demand. Under fault conditions where this balance is disrupted, the Under-Frequency Load Shedding scheme is typically the ultimate resource employed to prevent the frequency from dropping to undesirable thresholds that could lead to a blackout. Smart loads have the capability to dynamically adjust their consumption in response to frequency variations, which has the potential to enhance frequency regulation and mitigate the need for abrupt load disconnection through the Under-Frequency Load Shedding scheme. The objective of this paper is to present a literature review of Under-Frequency Load Shedding schemes, an innovative approach to their classifications, and the introduction of a new category within these schemes that incorporates smart loads. Additionally, an overview of smart loads is included to be potentially employed in the design of new schemes and contribute to a shift in the operation philosophy, considering that the primary mission of electric power systems is to provide energy to loads rather than disconnecting them.
Under-frequency load shedding (UFLS) schemes are the latest safety measures applied for safeguarding the integrity of the grid against abrupt frequency imbalances. The overall inertia of electrical power systems is expected to decrease with an increased penetration of renewable energy as well as elements connected through power electronic interfaces. However, voltage source converter-based high voltage direct current (VSC-HVDC) links can provide virtual inertia through a control loop that allows for a reaction to occur at certain frequency fluctuations. This paper evaluates a UFLS scheme that considers the injection of virtual inertia through a VSC-HVDC link. A genetic algorithm (GA) is used to determine the location of the UFLS relays, the activation threshold of each stage, the delay time and the percentage of load shedding at each stage. It was found that the virtual inertia causes the nadir to delay and sometimes reach a greater depth. Furthermore, the implemented GA approximates the frequency response to the limits set with the constraints, reducing the load shedding but achieving a steeper nadir and a lower steady-state frequency level than traditional UFLS. The simulations were performed using the IEEE 39-bus test system.
This paper addresses the optimal placement and sizing of Modular Static Synchronous Series Compensators (M-SSSCs) to enhance power system performance. The proposed methodology optimizes four key objectives: reducing transmission line loadability, minimizing power losses, mitigating voltage deviations, and enhancing voltage stability using the L-index. The methodology is validated on two systems: the IEEE 14-bus test network and a sub-area of the Colombian power grid, characterized by aging infrastructure and operational challenges. The optimization process employs three metaheuristic algorithms—Genetic Algorithm (GA), Particle Swarm Optimization (PSO), and Teaching–Learning-Based Optimization (TLBO)—to identify optimal configurations. System performance is analyzed under both normal operating conditions and contingency scenarios (N − 1). The results demonstrate that M-SSSC deployment significantly reduces congestion, enhances voltage stability, and improves overall system efficiency. Furthermore, this work highlights the practical application of M-SSSC in modernizing real-world grids, aligning with sustainable energy transition goals. This study identifies the optimal M-SSSC configurations and placement alternatives for the analyzed systems. Specifically, for the Colombian sub-area, the most suitable solutions involve installing M-SSSC devices in capacitive mode on the Termocol–Guajira and Santa Marta–Guajira 220 kV transmission lines.
Assessing the impact of electric vehicle (EV) integration on power systems is crucial, particularly regarding frequency stability, which often remains largely unaddressed, especially in developing countries. This paper examines the effects of EV penetration on the frequency stability of Curaçao’s power network, an aspect not previously studied for the island. As a key contribution, we present a representative model of Curaçao’s power network, adjusting the dynamic models of the speed governors of synchronous machines, using data available to the academic community. Additionally, we analyze the impacts of EVs on the grid’s frequency stability under different EV participation scenarios. To achieve this, simulations were conducted considering various EV participation scenarios and different types of chargers to assess their impact on grid stability. The study evaluates key frequency stability metrics, including the rate of change of frequency (RoCoF) as well as the highest and lowest frequency values during the transient period. The results indicated that higher EV penetration can significantly impact frequency stability. The observed increase in the RoCoF and frequency zenith values suggests a weakening of the grid’s ability to withstand frequency disturbances, particularly in high-EV-penetration scenarios.
Traditionally, the dynamics of power systems have been governed by synchronous generators and their associated rotating masses. However, with the increasing penetration of renewable generation and power electronic interfaces, the inertia contributed by rotating machines has been gradually displaced. This makes it imperative to study alternative elements capable of mitigating the reduction in inertia in modern power systems. This article addresses the problem of optimal sizing and placement of Battery Energy Storage Systems to enhance frequency response in power grids through the application of optimization techniques such as Genetic Algorithms (GA) and Particle Swarm Optimization (PSO). Several inertia scenarios are analyzed, where the algorithms determine the optimal locations for Battery Energy Storage Systems units while minimizing the total installed Battery Energy Storage Systems capacity. As key contributions, this study models Battery Energy Storage Systems units, which emulate inertial responses based on the system’s Rate of Change of Frequency, and evaluates the impact of Battery Energy Storage Systems on frequency stability by analyzing parameters such as the frequency nadir, zenith, and steady-state frequency according to the installed Battery Energy Storage System’s size and location. A comparative analysis of the optimization scenarios shows that the Particle Swarm Optimization algorithm with 50% rotational inertia is the most efficient, requiring the lowest total installed power (277.11 MW). It is followed by the Particle Swarm Optimization algorithm with 100% rotational inertia (285.79 MW) and Genetic Algorithms with 50% rotational inertia (285.57 MW). In contrast, Genetic Algorithms with 25% rotational inertia demand the highest total installed Battery Energy Storage Systems power (307.44 MW), a result directly associated with a significant reduction in system inertia. Overall, an inverse relationship is observed between the available inertia level and the required Battery Energy Storage Systems capacity: the lower the inertia, the greater the power that the Battery Energy Storage Systems must supply to keep the system frequency within acceptable operational limits.
This paper proposes the integration and operation of lithium-ion battery energy storage systems (ESS) in active distribution networks with high penetration of distributed generation based on renewable energy. The goal is to minimize total system costs, including energy purchasing at the substation node, as well as ESS integration, maintenance, and replacement costs over a 20-year planning horizon. The proposed master–slave methodology uses the Salp Swarm Optimization Algorithm to determine ESS location, technology, and daily operation schemes, combined with a successive approximation power flow to compute the objective function value and enforce constraints. This approach employs a discrete–continuous encoding, reducing processing times and increasing the likelihood of finding the global optimum. Validated on a 33-node test system adapted to Medellín, Colombia, the methodology outperformed five metaheuristic algorithms, achieving the highest annual savings (USD 16,605.77), the lowest average cost (USD 2,964,139.99), and the fastest processing time (345.71 s). The results demonstrate that the proposed methodology enables network operators to reduce distribution network costs effectively, offering high repeatability, solution quality, and computational efficiency.