Felix Boehm

Mr. Felix Boehm

Department of Otorhinolaryngology, Head and Neck Surgery, Ulm University Medical Center
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2021 in Cancers
Verified
Journal Article
Open access
PDF file
FBFelix Boehm
Felix Boehm
RGRene Graesslin
Rene Graesslin
MTMarie-Nicole Theodoraki
Marie-Nicole Theodoraki
LSLeon R. Schild
Leon R. Schild
JGJens Greve
Jens Greve
PSPatrick J. Schuler
Patrick J. Schuler
Background. In the past few years, surgical robots have recently entered the medical field, particularly in urology, gynecology, and general surgery. However, the clinical effectiveness and safety of robot-assisted surgery (RAS) in the field of head and neck surgery has not been clearly established. In this review, we evaluate to what extent RAS can potentially be applied in head and neck surgery, in which fields it is already daily routine and what advantages can be seen in comparison to conventional surgery. Data sources. For this purpose, we conducted a systematic review of trials published between 2000 and 2021, as well as currently ongoing trials registered in clinicaltrials.gov. The results were structured according to anatomical regions, for the topics “Costs,” “current clinical trials,” and “robotic research” we added separate sections for the sake of clarity. Results. Our findings show a lack of large-scale systematic randomized trials on the use of robots in head and neck surgery. Most studies include small case series or lack a control arm which enables a comparison with established standard procedures. Conclusion. The question of financial reimbursement is still not answered and the systems on the market still require some specific improvements for the use in head and neck surgery.

4 June 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JWJens Ulrich Werner
Jens Ulrich Werner
FBFelix Boehm
Felix Boehm
GLGabriele E. Lang
Gabriele E. Lang
JDJens Dreyhaupt
Jens Dreyhaupt
GLGerhard K. Lang
Gerhard K. Lang
CEChristian Enders
Christian Enders
To compare area of foveal avascular zone (FAZ) in different retinal vascular layers in optical coherence tomography angiography (OCTA) and fluorescein angiography (FA) in patients with retinal vein occlusion (RVO). Prospective cross-sectional comparative study in 47 eyes of 47 patients. FA was recorded with the Zeiss FF450plusIR camera and OCTA was obtained with the Zeiss Cirrus 5000 equipped with the AngioPlex module. Area of FAZ was graded by two independent investigators and calculated with Adobe Photoshop. Analysis for the total study population as well as subgroup analysis for branch retinal vein occlusion (BRVO), central retinal vein occlusion (CRVO) and patients with and without macular edema (ME) was performed. For all patients, FAZ was 0.449 mm2 in FA, 0.496 mm2 in OCTA superficial capillary layer (SCL) and 3.168 in OCTA deep capillary layer (DCL). In patients without ME FAZ was 0.288 mm2 in FA, 0.342 mm2 in OCTA SCL and 1.384 mm2 in OCTA DCL. FAZ area measurement in patients with ME revealed 0.482 mm2 in FA, 0.527 mm2 in OCTA SCL and 3.554 mm2 in OCTA DCL. Especially the SCL of OCTA shows a good agreement to FA in measurement of FAZ in all patients with low limits of variation in patients without ME. There were no considerable differences in BRVO and CRVO. OCTA could replace FA in FAZ area measurement in patients with RVO, especially in those without ME, achieving similar measurements whilst being non-invasive

30 January 2025 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Open access
FBFelix Boehm
Felix Boehm
AAAnna Alperovich
Anna Alperovich
CSCarolin Schwamborn
Carolin Schwamborn
MMMayar Mostafa
Mayar Mostafa
TGTommaso Giannantonio
Tommaso Giannantonio
PSPatrick J. Schuler
Patrick J. Schuler
Head and neck cancers, constituting 3-5% of all cancer cases, often require surgical resection for optimal outcomes. Achieving complete resection (R0) is crucial, but current methods, relying on white light endoscopy and microscopy, have limitations. Hyperspectral imaging (HSI) offers potential benefits by capturing detailed spectral information beyond human vision. This study enrolled 32 patients with head and neck squamous cell carcinoma (HNSCC). Following surgical resection specimens underwent ex vivo HSI imaging. Annotated regions were utilized to train a Convolutional Neural Network (CNN) and Graph Neural Network (GNN). Imaging parameters were carefully optimized for efficiency. Our HSI imaging setup required around 12 min per measurement and demonstrated feasibility with promising accuracy. The combination of HSI and artificial intelligence (AI) achieved an 86% accuracy in predicting tumor tissue. Challenges included data volume and extended capture times. Hyperspectral imaging, complemented by AI, shows promise in enhancing tissue differentiation for HNSCC. The study envisions real-time integration of HSI into surgery for margin assessment. Challenges such as data volume and capture times warrant further exploration, emphasizing the need for ongoing investigations to refine clinical applications.

25 June 2020 in The Laryngoscope
Verified
Journal Article
Open access
PDF file
LSLeon R. Schild
Leon R. Schild
FBFelix Boehm
Felix Boehm
MBMarco Boos
Marco Boos
LKLüder A. Kahrs
Lüder A. Kahrs
JCJan Coburger
Jan Coburger
PSPatrick J. Schuler
Patrick J. Schuler
Objectives: Transoral surgery of the larynx with rigid instruments is not always possible. This may result in insufficient therapy or in an increased need for open surgery. For these patients, alternative surgical systems are needed. Here, we demonstrate a curved prototype for laryngeal surgery equipped with flexible instruments.Study Design: Pre‐clinical user study in an ex vivo porcine laryngeal model.Methods: The prototype was built from established medical devices, namely a hyperangulated videolaryngoscope and modified flexible instruments as well as three‐dimensional printed parts. Feasibility of laryngeal manipulation was evaluated in a user study (n = 19) with a porcine ex vivo laryngeal model. Using three different visualization technologies, the participants performed various fine motor skills tasks and rated the usability of the system on a 5‐point Likert scale.Results: Exposure, accessibility, and manipulation of important laryngeal structures were always possible using the new prototype. The participants needed considerably less time (mean, 96.4 seconds ± 6.4 seconds vs. 111.5 seconds ± 4.5 seconds, P = .18), reported significantly better general impression (mean score 3.0 vs. 3.8, P = .041) and significantly lower user head and neck strain (2.6 vs. 1.7, P = .022) using a 40‐inch television screen as compared to a standard videolaryngoscope monitor.Conclusion: The results indicate that our curved prototype and large monitor visualization may provide a cost‐effective minimally invasive alternative for difficult laryngeal exposure. Its special advantages include avoiding the need for a straight line of sight and a simple and cost‐effective construction. The system could be further improved through advances in camera chip technology and smaller instruments. Laryngoscope, 131:E561–E568, 2021

29 July 2020 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Open access
FBFelix Boehm
Felix Boehm
DFDaniel T. Friedrich
Daniel T. Friedrich
FSFabian Sommer
Fabian Sommer
MSMarc‐Oliver Scheithauer
Marc‐Oliver Scheithauer
JGJens Greve
Jens Greve
PSPatrick J. Schuler
Patrick J. Schuler
Background Distal nasolacrimal duct stenosis is usually treated by head and neck surgeons with transnasal endoscopic dacryocystorhinostomy (DCR). The presented clinical study discusses advantages and drawbacks of a robot‐assisted endoscope positioning system, which allows for hands‐free visualization of the surgical field. Material and Methods Two patients were treated by surgical DCR. The endoscopic positioning system (Medineering®) features a mechatronic holding arm with four segments and seven degrees of freedom. It is driven by using a foot pedal. Results Visualization and instrumentation of the surgical field including the relevant anatomical landmarks were feasible. The endoscope position could be controlled with sufficient precision. The surgeon was able to maintain bimanual instrumentation. Conclusion The endoscope positioning system allows for two‐handed surgery, which facilitates the essential steps of the surgical procedure. If the benefit of the system is sufficient for the use in clinical routine, it has to be evaluated in repeated applications.

17 March 2022 in HNO
Verified
Journal Article
Closed access
PDF file
FBFelix Boehm
Felix Boehm
TBT. Braun
T. Braun
JGJ. Greve
J. Greve
SLS. Laban
S. Laban
JLJ. P. Lingl
J. P. Lingl
PSP. J. Schuler
P. J. Schuler