Background. In the past few years, surgical robots have recently entered the medical field, particularly in urology, gynecology, and general surgery. However, the clinical effectiveness and safety of robot-assisted surgery (RAS) in the field of head and neck surgery has not been clearly established. In this review, we evaluate to what extent RAS can potentially be applied in head and neck surgery, in which fields it is already daily routine and what advantages can be seen in comparison to conventional surgery. Data sources. For this purpose, we conducted a systematic review of trials published between 2000 and 2021, as well as currently ongoing trials registered in clinicaltrials.gov. The results were structured according to anatomical regions, for the topics “Costs,” “current clinical trials,” and “robotic research” we added separate sections for the sake of clarity. Results. Our findings show a lack of large-scale systematic randomized trials on the use of robots in head and neck surgery. Most studies include small case series or lack a control arm which enables a comparison with established standard procedures. Conclusion. The question of financial reimbursement is still not answered and the systems on the market still require some specific improvements for the use in head and neck surgery.
Objectives: Transoral surgery of the larynx with rigid instruments is not always possible. This may result in insufficient therapy or in an increased need for open surgery. For these patients, alternative surgical systems are needed. Here, we demonstrate a curved prototype for laryngeal surgery equipped with flexible instruments.Study Design: Pre‐clinical user study in an ex vivo porcine laryngeal model.Methods: The prototype was built from established medical devices, namely a hyperangulated videolaryngoscope and modified flexible instruments as well as three‐dimensional printed parts. Feasibility of laryngeal manipulation was evaluated in a user study (n = 19) with a porcine ex vivo laryngeal model. Using three different visualization technologies, the participants performed various fine motor skills tasks and rated the usability of the system on a 5‐point Likert scale.Results: Exposure, accessibility, and manipulation of important laryngeal structures were always possible using the new prototype. The participants needed considerably less time (mean, 96.4 seconds ± 6.4 seconds vs. 111.5 seconds ± 4.5 seconds, P = .18), reported significantly better general impression (mean score 3.0 vs. 3.8, P = .041) and significantly lower user head and neck strain (2.6 vs. 1.7, P = .022) using a 40‐inch television screen as compared to a standard videolaryngoscope monitor.Conclusion: The results indicate that our curved prototype and large monitor visualization may provide a cost‐effective minimally invasive alternative for difficult laryngeal exposure. Its special advantages include avoiding the need for a straight line of sight and a simple and cost‐effective construction. The system could be further improved through advances in camera chip technology and smaller instruments. Laryngoscope, 131:E561–E568, 2021
Introduction: The prerequisite for transoral microsurgery of laryngeal lesions is an uninterrupted line of sight to the operative field. Patients with cervical stiffness or anatomical variations that prevent adequate laryngeal exposure are typically unsuitable for this procedure. In such cases, a curved video laryngoscope may facilitate improved access to the larynx. However, conventional suspension laryngoscopy setups are incompatible with standard video laryngoscopes.Objective: This study evaluates three attachment methods for integrating a curved video laryngoscope into a surgical setup, focusing on their resistance to external forces.Methods: This study assessed three different attachment methods (3D‐printed clamp vs. metal bracket vs. articulated stand) for a video laryngoscope in a surgical setup. External forces, both lateral and rotational (torque), were applied and continuously measured until laryngeal visualization was compromised by displacement of the video laryngoscope.Results: The metal bracket demonstrated significantly (p < 0.001) higher resistance to lateral forces (median 184.49 N, 95% CI [181.59–189.61 N]) compared to the articulated stand (median 88.16 N, 95% CI [76.73–88.98 N]) and the 3D‐printed clamp (median 55.59 N, 95% CI [54.74–57.58 N]). The articulated stand exhibited significantly (p < 0.005) greater torque resistance (median 9.57 N m, 95% CI [5.65–9.87 N m]) compared to the metal bracket (median 1.58 N m, 95% CI [1.57–2.13 N m]) and the 3D‐printed clamp (median 2.46 N m, 95% CI [2.24–2.79 N m]).Conclusion: Overall, the articulated stand outperformed the other attachment methods, displaying robust resistance to lateral forces and superior rotational stability.Level of Evidence: Level 4.